4x outputs (H bridge) with PWM control and 24 to 48 VDC ±25% supply6 A nominal current (10 A max current)15 Hz to 50 kHz frequency, 16-bitPWM resolution, 15-bit, + sign, minimum 10 nsConfigurable dith…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

4x outputs (H bridge) with PWM control and 24 to 48 VDC ±25% supply6 A nominal current (10 A max current)15 Hz to 50 kHz frequency, 16-bitPWM resolution, 15-bit, + sign, minimum 10 nsConfigurable dither4x 4 inputs 24V, can be configured as ABRSink connection1-wire connections

The PMW motor bridge module is used to control 4 DC motors with a nominal voltage of 24 to 48 VDC ±25% at a nominal current up to 6 A.

Specification

I/O module4-channel PWM motor bridge, 4 ABR incremental encoders
B&R ID code0xA177
Status indicatorsI/O function per channel, operating state, module status
Module run/errorYes, using LED status indicator and software
OutputYes, using LED status indicator and software
I/O power supplyYes, using software
Bus0.01 W
Internal I/O2.4 W
24 VDC2 W / channel
48 VDC2.1 W / channel
60 VDC2.2 W / channel
Additional power dissipation caused by actuators (resistive) [W]
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X
ULcURus E225616 Power conversion equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
KCYes
Quantity4
Nominal voltage24 to 48 VDC ±25%
Input characteristics per EN 61131-2Type 1
Input voltage24 VDC (-15% / +20%)
Input current at 24 VDCApprox. 4 mA
Input circuitSink
Hardware<5 µs
Software
Connection type1-wire connections
Input resistanceTyp. 6 kΩ
Additional functions4x ABR incremental encoder
Low<5 VDC
High>15 VDC
Insulation voltage between channel and bus500 Veff
Encoder inputs24 V, asymmetrical
Counter size16-bit
Input frequencyMax. 50 kHz
Evaluation4x
Signal formSquare wave pulse
Nominal current6 A
Maximum current10 A (2 s)
PWM frequency15 Hz to 50 kHz
SupplyExternal
FuseRequired line fuse: Max. 32 A slow-blow (see “Overcurrent protection”)
Output protectionThermal shutdown in the event of overcurrent or short circuit
VariantH bridge
Configurable ditherAmplitude, frequency
Period duration resolution16-bit, min. 20 μs
Phase shift PWM1, 2, 3, 490° each
DC bus capacitance680 μF
PWM mode15 bits plus sign ≥10 ns
Current mode15 bits plus sign ≥10 ns
Electrical isolationChannel isolated from bus Channel not isolated from channel
HorizontalYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Horizontal mounting orientation0 to 50°C
Vertical mounting orientationNot permitted
Derating
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing
NoteOrder 2x terminal block X20TB12 separately. Order 1x terminal block 0TB3103-7020 separately.
Pitch87.5+0.2 mm
ConditionUsed
RevisionRev. C0, Rev. D0, Rev. E0