Fast delivery within 72 Hours

B&R X20MM4456

4x outputs (H bridge) with PWM control and 24 to 48 VDC ±25% supply6 A nominal current (10 A max current)15 Hz to 50 kHz frequency, 16-bitPWM resolution, 15-bit, + sign, minimum 10 nsConfigurable dith…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

4x outputs (H bridge) with PWM control and 24 to 48 VDC ±25% supply6 A nominal current (10 A max current)15 Hz to 50 kHz frequency, 16-bitPWM resolution, 15-bit, + sign, minimum 10 nsConfigurable dither4x 4 inputs 24V, can be configured as ABRSink connection1-wire connections

The PMW motor bridge module is used to control 4 DC motors with a nominal voltage of 24 to 48 VDC ±25% at a nominal current up to 6 A.

Specification

I/O module

4-channel PWM motor bridge, 4 ABR incremental encoders

B&R ID code

0xA177

Status indicators

I/O function per channel, operating state, module status

Module run/error

Yes, using LED status indicator and software

Output

Yes, using LED status indicator and software

I/O power supply

Yes, using software

Bus

0.01 W

Internal I/O

2.4 W

24 VDC

2 W / channel

48 VDC

2.1 W / channel

60 VDC

2.2 W / channel

Additional power dissipation caused by actuators (resistive) [W]

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cURus E225616
Power conversion equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

KC

Yes

Quantity

4

Nominal voltage

24 to 48 VDC ±25%

Input characteristics per EN 61131-2

Type 1

Input voltage

24 VDC (-15% / +20%)

Input current at 24 VDC

Approx. 4 mA

Input circuit

Sink

Hardware

<5 µs

Software

Connection type

1-wire connections

Input resistance

Typ. 6 kΩ

Additional functions

4x ABR incremental encoder

Low

<5 VDC

High

>15 VDC

Insulation voltage between channel and bus

500 Veff

Encoder inputs

24 V, asymmetrical

Counter size

16-bit

Input frequency

Max. 50 kHz

Evaluation

4x

Signal form

Square wave pulse

Nominal current

6 A

Maximum current

10 A (2 s)

PWM frequency

15 Hz to 50 kHz

Supply

External

Fuse

Required line fuse: Max. 32 A slow-blow (see "Overcurrent protection")

Output protection

Thermal shutdown in the event of overcurrent or short circuit

Variant

H bridge

Configurable dither

Amplitude, frequency

Period duration resolution

16-bit, min. 20 μs

Phase shift PWM1, 2, 3, 4

90° each

DC bus capacitance

680 μF

PWM mode

15 bits plus sign ≥10 ns

Current mode

15 bits plus sign ≥10 ns

Electrical isolation

Channel isolated from bus
Channel not isolated from channel

Horizontal

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

0 to 50°C

Vertical mounting orientation

Not permitted

Derating

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

5 to 95%, non-condensing

Note

Order 2x terminal block X20TB12 separately.