Fast delivery within 72 Hours
B&R X20ET8819
NetTime time stamp has a resolution of 20 nsRecording and analysis of CRC and frame errorsTriggers can also be activated using external digital signalsAnalysis of both half-duplex and full-duplex netw…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
NetTime time stamp has a resolution of 20 nsRecording and analysis of CRC and frame errorsTriggers can also be activated using external digital signalsAnalysis of both half-duplex and full-duplex networksAble to record two networks simultaneously
POWERLINK has proven itself in the field for years and rarely has problems during commissioning and production. Nonetheless, it is still possible for communication disturbances to occur due to damaged or poor quality cables. If an error occurs, localizing and correcting it is usually very easy thanks to the heterogeneous structure of this flat network type (all data is always visible throughout the network). What’s problematic are errors that occur sporadically. This is where tools such as Omnipeek or Wireshark come in.These tools (or more likely the standard PC technology being used) reach their limits, however, when dealing with machines that have short network cycles. Either not all frames can be recorded, or some telegrams are lost altogether. In these cases, what’s needed is a special hardware tool that can work very quickly, record and save every bit of traffic and then pass it on to a laptop.This module provides different operating modes. For example, it can work passively on the network, in which case the real-time behavior remains unchanged. The device listens in and selectively takes in data when certain defined trigger conditions are met. It can read all of the data, mark it with a timestamp, store it temporarily and ultimately pass it on to a PC. The data is then analyzed in the familiar PC environment.
Specification
| Ethernet analysis tool |
Ethernet analysis tool with up to 2 slots for hub expansion modules |
|---|---|
| Status indicators |
Module status, bus function |
| Module status |
Yes, using LED status indicator and software |
| Bus function |
Yes, using LED status indicator and software |
| Power consumption |
2 W |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc |
| UL |
cULus E115267 |
| HazLoc |
cCSAus 244665 |
| KC |
Yes |
| Type |
Ethernet analysis tool |
| Variant |
2x shielded RJ45 |
| Line length |
Max. 100 m between 2 stations (segment length) |
| Transfer rate |
100 Mbit/s |
| Physical layer |
100BASE-TX |
| Half-duplex |
Yes |
| Full-duplex |
Yes |
| Autonegotiation |
Yes |
| Auto-MDI/MDIX |
Yes |
| Electrical isolation |
POWERLINK (IF1, IF2) isolated from power supply |
| Horizontal |
Yes |
| Vertical |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Horizontal mounting orientation |
-25 to 60°C |
| Vertical mounting orientation |
-25 to 50°C |
| Derating |
– |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
5 to 95%, non-condensing |
| Note |
Order 1x terminal block X20TB12 separately. |
| X20BB80 |
37.5+0.2 mm |
| X20BB81 |
62.5+0.2 mm |
| X20BB82 |
87.5+0.2 mm |

Reviews
Clear filtersThere are no reviews yet.