Fast delivery within 72 Hours
B&R X20EM0611
Intel Atom 400 MHz compatible with integrated I/O processorEthernet, POWERLINK V2 with poll-response chaining, onboard USB and RS485512 MB LPDDR4 SDRAM1 GB onboard flash driveFanlessNo battery…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Intel Atom 400 MHz compatible with integrated I/O processorEthernet, POWERLINK V2 with poll-response chaining, onboard USB and RS485512 MB LPDDR4 SDRAM1 GB onboard flash driveFanlessNo battery
This compact yet powerful controller is based on Intel Atom processor technology. The fanless, battery-free design of this controller means it is completely maintenance-free.The basic configuration includes USB, Ethernet, POWERLINK V2, RS485 and a flash drive.
Specification
| Interfaces | 1x RS485, 1x Ethernet (2-port switch), 1x POWERLINK (V2), 2x USB, 1x X2X Link |
|---|---|
| System module | Controller |
| B&R ID code | 0x289B |
| Cooling | Fanless |
| Status indicators | CPU function, Ethernet, POWERLINK, RS485, I/O power supply |
| CPU function | Yes, using LED status indicator |
| Ethernet | Yes, using LED status indicator |
| I/O power supply | Yes, using software and LED status indicator |
| POWERLINK | Yes, using LED status indicator |
| Temperature | Yes, using software register |
| Controller redundancy | No |
| Storage health data support | Yes |
| ACOPOS support | Yes |
| Visual Components support | Yes |
| Power consumption | 4.6 W |
| Power consumption for X2X Link power supply | 0.6 W |
| Internal I/O | 0.56 W |
| Additional power dissipation caused by actuators (resistive) [W] | – |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X |
| UL | cULus E115267 Industrial control equipment |
| HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| Input voltage | 24 VDC -15% / +20% (nominal voltage: 24 VDC) (max. input power at nominal voltage: 240 W) |
| Input current | Max. 1.4 A at 24 VDC |
| Fuse | Required line fuse: Max. 10 A, slow-blow |
| Reverse polarity protection | Yes |
| Nominal output power | 3.5 W |
| Parallel connection | Yes |
| Redundant operation | Yes |
| Nominal output voltage | 24 VDC |
| Permissible contact load | 10 A |
| Real-time clock | Retention for at least 300 hours, typ. 1000 hours at 25°C, 1 s resolution, <30 s/month accuracy at 25°C |
| FPU | Yes |
| Type | USB 1.1/2.0 |
| Clock frequency | 400 MHz (compatible). |
| Data code | 24 kB |
| Program code | 32 kB |
| L2 cache | 1 MB |
| Integrated I/O processor | Processes I/O data points in the background |
| Modular interface slots | |
| Remanent variables | Max. 64 kB, retention >10 years |
| Shortest task class cycle time | 400 µs |
| Typical instruction cycle time | 0.0044 µs |
| RAM | 512 MB LPDDR4 SDRAM |
| Data retention | 10 years |
| Guaranteed | 40 TB |
| Results for 5 years | 21.9 GB/day |
| Guaranteed erase/write cycles | 20,000 |
| Error-correcting code (ECC) | Yes |
| Signal | RS485 |
| Variant | Connection via 6-pin terminal block |
| Line length | Max. 100 m between 2 stations (segment length) |
| Transfer rate | Max. 115.2 kbit/s |
| Physical layer | 100BASE-TX |
| Half-duplex | Yes |
| Full-duplex | POWERLINK mode: No / Ethernet mode: Yes |
| Autonegotiation | Yes |
| Auto-MDI/MDIX | Yes |
| Fieldbus | X2X Link master |
| Max. output current | 0.5 A |
| Max. distance | 1000 m |
| Terminating resistor | Integrated in PLC, not switchable |
| Electrical isolation | Ethernet (IF2), POWERLINK (IF3), X2X (IF6) and RS485 (IF7) isolated from each other, from other interfaces and from PLC I/O to PLC isolated from all interfaces USB (IF4 and IF5) not isolated from PLC |
| Horizontal | Yes |
| Vertical | Yes |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.6°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
| Horizontal mounting orientation | -25 to 60°C |
| Vertical mounting orientation | -25 to 50°C |
| Derating | – |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
| Operation | 5 to 95%, non-condensing |
| Note | X20 end cover plate (right) included in delivery 2- and 6-pin terminal block included in delivery |
| Width | 55 mm |
| Height | 124 mm |
| Depth | 92 mm |
| Weight | 475 g |

Reviews