B&R X20DS1928
EnDat 2.1 and EnDat 2.2 encoder interfaceEncoder input monitoring5 VDC and GND for encoder supplyNetTime timestamp: Position time
The module is equipped wi…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
EnDat 2.1 and EnDat 2.2 encoder interfaceEncoder input monitoring5 VDC and GND for encoder supplyNetTime timestamp: Position time
The module is equipped with an EnDat encoder interface. The module automatically detects whether an encoder is connected with EnDat 2.1 or EnDat 2.2. This module can be used to evaluate encoders installed in B&R servo motors as well as encoders for external axes (encoders that scan any machine movement). The input signals are monitored. This makes it possible to detect open or shorted lines as well as encoder supply failures.
Specification
| I/O module |
1x EnDat interface |
|---|---|
| B&R ID code |
0xA912 |
| Status indicators |
Counting direction, operating state, module status |
| Module run/error |
Yes, using LED status indicator and software |
| Counting direction |
Yes, using LED status indicator |
| Bus |
0.01 W |
| Internal I/O |
1.3 W |
| Additional power dissipation caused by actuators (resistive) [W] |
– |
| Type of signal lines |
Shielded lines must be used for all signal lines. |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 GcIP20, Ta (see X20 user's manual)FTZÚ 09 ATEX 0083X |
| UL |
cULus E115267Industrial control equipment |
| HazLoc |
cCSAus 244665Process control equipmentfor hazardous locations Class I, Division 2, Groups ABCD, T5 |
| KC |
Yes |
| Type |
EnDat 2.1/2.2 |
| Angular position resolution |
13-bit, with a signal of 1 VSS |
| Encoder monitoring |
Yes |
| Max. encoder cable length |
10 m, with wire cross section 4x 2x 0.14 mm2 and 1x 2x 0.5 mm2 |
| Signal transmission |
5 VDC differential signal, EiA RS485 standard |
| Signal frequency |
DC up to 400 kHz |
| Differential voltage |
1 VSS |
| Common-mode voltage |
Max. ±10 V |
| Terminating resistor |
120 Ω |
| Output voltage |
5 V (±5%) |
| Load capacity |
300 mA |
| Overload-proof |
Yes |
| Short-circuit proof |
Yes |
| Transmission status |
See the EnDat specification. |
| Electrical isolation |
Channel isolated from busChannel not isolated from channel |
| Horizontal |
Yes |
| Vertical |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Horizontal mounting orientation |
-25 to 60°C |
| Vertical mounting orientation |
-25 to 50°C |
| Derating |
See section "Derating". |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
5 to 95%, non-condensing |
| Note |
Order 1x terminal block X20TB12 separately.Order 1x bus module X20BM11 separately. |
| Pitch |
12.5+0.2 mm |