Fast delivery within 72 Hours
B&R X20DS1828
HIPERFACE encoder interfaceEncoder input monitoring11 VDC and GND for encoder supplyNetTime timestamp: Position time
The module is equipped with 1 HIPERFAC…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
HIPERFACE encoder interfaceEncoder input monitoring11 VDC and GND for encoder supplyNetTime timestamp: Position time
The module is equipped with 1 HIPERFACE encoder interface. This module can be used to evaluate encoders installed in motors from other manufacturers as well as encoders for external axes (encoders that sample any machine movement). The input signals are monitored. This makes it possible to detect open or shorted lines as well as encoder supply failures.
Specification
| I/O module |
1x HIPERFACE interface |
|---|---|
| B&R ID code |
0xAEC7 |
| Status indicators |
Counting direction, operating state, module status |
| Module run/error |
Yes, using LED status indicator and software |
| Counting direction |
Yes, using LED status indicator |
| Bus |
0.01 W |
| Internal I/O |
1.3 W |
| Additional power dissipation caused by actuators (resistive) [W] |
– |
| Type of signal lines |
Shielded lines must be used for all signal lines. |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 GcIP20, Ta (see X20 user's manual)FTZÚ 09 ATEX 0083X |
| UL |
cULus E115267Industrial control equipment |
| HazLoc |
cCSAus 244665Process control equipmentfor hazardous locations Class I, Division 2, Groups ABCD, T5 |
| KC |
Yes |
| Angular position resolution |
13-bit, with a signal of 1 VSS |
| Encoder monitoring |
Yes |
| Max. encoder cable length |
10 m |
| Signal transmission |
5 VDC differential signal, EiA RS485 standard |
| Signal frequency |
DC up to 200 kHz |
| Differential voltage |
1 VSS |
| Common-mode voltage |
Max. ±10 V |
| Terminating resistor |
120 Ω |
| Output voltage |
11 V |
| Load capacity |
150 mA |
| Overload-proof |
Yes |
| Short-circuit proof |
Yes |
| Transmission status |
See the HIPERFACE specification. |
| Electrical isolation |
Channel isolated from busChannel not isolated from channel |
| Horizontal |
Yes |
| Vertical |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Horizontal mounting orientation |
-25 to 60°C |
| Vertical mounting orientation |
-25 to 50°C |
| Derating |
See section "Derating". |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
5 to 95%, non-condensing |
| Note |
Order 1x terminal block X20TB12 separately.Order 1x bus module X20BM11 separately. |
| Pitch |
12.5+0.2 mm |

Reviews
Clear filtersThere are no reviews yet.