Fast delivery within 72 Hours

B&R X20DO6325

6 digital outputsSource connection2-wire connectionsGND for signal supplyIntegrated output protection1-wire connection type with 6-pin terminal blockDiagnostic functions (open line, short circuit and…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

6 digital outputsSource connection2-wire connectionsGND for signal supplyIntegrated output protection1-wire connection type with 6-pin terminal blockDiagnostic functions (open line, short circuit and overload/overtemperature)OSP mode

The module is equipped with six outputs for 1 or 2-wire connections with diagnostic functions. The X20 6-pin terminal block can be used for universal 1-line wiring. Two-line wiring can be implemented using the 12-pin terminal block. The outputs on the module are designed for source connections.

Specification

I/O module

6 digital outputs 24 VDC for 1- or 2-wire connections with diagnostic function

B&R ID code

0xE284

Status indicators

I/O function per channel, diagnostics per channel, operating state, module status

Module run/error

Yes, using LED status indicator and software

Status outputs

Yes, using LED status indicator and software

Diagnostic outputs

Yes, using LED status indicator and software

Bus

0.15 W

Internal I/O

0.4 W

Additional power dissipation caused by actuators (resistive) [W]

0.225

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

DNV

Temperature: B (0 to 55°C)
Humidity: B (up to 100%)
Vibration: B (4 g)
EMC: B (bridge and open deck)

CCS

Yes

LR

ENV1

KR

Yes

ABS

Yes

BV

EC33B
Temperature: 5 – 55°C
Vibration: 4 g
EMC: Bridge and open deck

Variant

Current-sourcing FET

Nominal voltage

24 VDC

Switching voltage

24 VDC -15% / +20%

Nominal output current

0.5 A

Total nominal current

3 A

Connection type

1- or 2-wire connections

Output circuit

Source

Output protection

Thermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current")
Internal freewheeling diode for switching inductive loads (see section "Switching inductive loads")

Open circuit

At <1 mA (typ.), detected if output OFF, delay approx. 10 ms

Short circuit to 24 VDC

Detected if output OFF, delay approx. 10 ms

Short circuit to GND

Detected if output ON, delay approx. 10 ms

Overload/Overtemperature

Detected if output ON, delay approx. 10 ms

Leakage current when the output is switched off

<160 μA

RDS(on)

150 mΩ

Peak short-circuit current

<40 A

Switch-on in the event of overload shutdown or short-circuit shutdown

Depends on the module temperature

0 → 1

<100 μs

1 → 0

<300 μs

Resistive load

Max. 2000 Hz

Inductive load

See section "Switching inductive loads".

Braking voltage when switching off inductive loads

45 to 52 VDC

Insulation voltage between channel and bus

510 Veff

Electrical isolation

Channel isolated from bus
Channel not isolated from channel and I/O power supply

Horizontal

Yes

Vertical

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

-25 to 60°C

Vertical mounting orientation

-25 to 50°C

Derating

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

5 to 95%, non-condensing

Note

Order 1x terminal block X20TB06 or X20TB12 separately.
Order 1x bus module X20BM11 separately.

Pitch

12.5+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20DO6325”