B&R X20DO4321

4 digital outputsSink connection3-wire connections24 VDC and GND for actuator supplyIntegrated output protectionOSP mode

This module is equipped with 4 out…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

4 digital outputsSink connection3-wire connections24 VDC and GND for actuator supplyIntegrated output protectionOSP mode

This module is equipped with 4 outputs with 3-wire connections as well as 24 VDC and GND for the actuator power supply. The outputs are designed for a sink circuit.

Specification

I/O module

4 digital outputs 24 VDC for 3-wire connections

B&R ID code

0x22B4

Status indicators

I/O function per channel, operating state, module status

Module run/error

Yes, using LED status indicator and software

Outputs

Yes, using LED status indicator and software (output error status)

Bus

0.16 W

Internal I/O

0.49 W

Additional power dissipation caused by actuators (resistive) [W]

+0.12

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

KC

Yes

Variant

FET current-sinking

Nominal voltage

24 VDC

Switching voltage

24 VDC -15% / +20%

Nominal output current

0.5 A

Total nominal current

2 A

Connection type

3-wire connections

Output circuit

Sink

Output protection

Thermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current")
Internal freewheeling diode for switching inductive loads (see section "Switching inductive loads")

Actuator power supply

Max. 12 W

Diagnostic status

Output monitoring with 10 ms delay

Leakage current when the output is switched off

75 µA

RDS(on)

120 mΩ

Peak short-circuit current

<7 A

Switch-on in the event of overload shutdown or short-circuit shutdown

Approx. 10 ms (depends on the module temperature)

0 → 1

<300 µs

1 → 0

<300 µs

Resistive load

Max. 500 Hz

Inductive load

See section "Switching inductive loads".

Braking voltage when switching off inductive loads

Typ. 50 VDC

Insulation voltage between channel and bus

500 Veff

Voltage

Module power supply minus voltage drop for short-circuit protection

Voltage drop for short-circuit protection at 500 mA

Max. 2 V

Short-circuit proof

Yes

Electrical isolation

Channel isolated from bus
Channel not isolated from channel and I/O power supply

Horizontal

Yes

Vertical

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

-25 to 60°C

Vertical mounting orientation

-25 to 50°C

Derating

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

5 to 95%, non-condensing