Fast delivery within 72 Hours

B&R X20DC2190

Ultrasonic transducer modulePath measurement (resolution 10 µm)Speed measurement (resolution 100 µm/s)1, 2, 3 and 4 magnetic rod measurements possibleDPI/IP protocol supported…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

Ultrasonic transducer modulePath measurement (resolution 10 µm)Speed measurement (resolution 100 µm/s)1, 2, 3 and 4 magnetic rod measurements possibleDPI/IP protocol supported

This module can be used to determine paths and to calculate speeds at the same time. The ultrasonic transducer rods are connected directly to the RS422 interface. Communication to the transducer rod takes place using start/stop signals. With the DPI/IP protocol, it is also possible, for example, to read operational properties directly from the transducer. During service (when a transducer is being exchanged) the machine can be started again quickly without additional configuration work. The module is designed for connecting 2 transducer rods with a total of up to 4 paths. That means, for example, that 2 ultrasonic transducers with 2 magnets each or one with 4 magnets can be used. The combination 3/1 is also possible. The module provides 24 VDC as an external supply for the sensor.

Specification

I/O module

Ultrasonic path measurement module, 2 path measurement rods, 4 path recorders, speed measurement

B&R ID code

0x2188

Status indicators

I/O function per channel, operating state, module status

Module run/error

Yes, using LED status indicator and software

Bus

0.01 W

Internal I/O

1.1 W

Additional power dissipation caused by actuators (resistive) [W]

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

KC

Yes

Quantity

2

Supported encoder types

Start/Stop interface
EP start/stop interface
DPI/IP interface

Voltage

24 VDC, module-internal, max. 150 mA

Monitoring

Configurable overvoltage/undervoltage monitoring (±10%, ±15%, ±20%, ±25%)

Short-circuit proof

Rev. D0 and later

Input and output level

RS422 differential level

Multi-magnet measurement

Yes, in combination per rod, max. 4 magnets total

Outputs

1.6 µs durational initialization pulse

Path measurement

Resolution = 0.01 mm, measurement range = ±5.2 m

Speed measurement

Resolution = 0.1 mm/s, measurement range = ±3.2 m/s

Accuracy

±50 ppm ±5 ppm/year

Short-circuit protection

No

Electrical isolation

Channel isolated from bus

Channel not isolated from channel

Horizontal

Yes

Vertical

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

-25 to 60°C

Vertical mounting orientation

-25 to 50°C

Derating

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

5 to 95%, non-condensing

Note

Order 1x terminal block X20TB12 separately.
Order 1x bus module X20BM11 separately.

Pitch

12.5+0.2 mm