Fast delivery within 72 Hours

B&R X20DC1198

1 SSI absolute encoder 5 V2 additional inputs5 VDC, 24 VDC and GND for encoder supply

This module is equipped with one input for SSI absolute encoders with…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

1 SSI absolute encoder 5 V2 additional inputs5 VDC, 24 VDC and GND for encoder supply

This module is equipped with one input for SSI absolute encoders with 5 V encoder signal.

Specification

I/O module

1 SSI absolute encoder 5 V

B&R ID code

0x1BB0

Status indicators

I/O function per channel, operating state, module status

Module run/error

Yes, using LED status indicator and software

Bus

0.01 W

Internal I/O

1.5 W

Additional power dissipation caused by actuators (resistive) [W]

Type of signal lines

Shielded lines must be used for all signal lines.

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

DNV

Temperature: B (0 to 55°C)
Humidity: B (up to 100%)
Vibration: B (4 g)
EMC: B (bridge and open deck)

CCS

Yes

LR

ENV1

KR

Yes

ABS

Yes

BV

EC33B
Temperature: 5 – 55°C
Vibration: 4 g
EMC: Bridge and open deck

KC

Yes

Quantity

2

Nominal voltage

24 VDC

Input characteristics per EN 61131-2

Type 1

Input voltage

24 VDC -15% / +20%

Input current at 24 VDC

Approx. 3.3 mA

Input circuit

Sink

Hardware

≤2 µs

Software

Connection type

3-wire connections

Input resistance

7.19 kΩ

Low

<5 VDC

High

>15 VDC

Insulation voltage between channel and bus

500 Veff

Encoder inputs

5 V, symmetrical

Counter size

32-bit

Max. transfer rate

1 Mbit/s

Coding

Gray/Binary

Insulation voltage between encoder and bus

500 Veff

Overload characteristics of encoder power supply

Short-circuit proof, overload-proof

Transfer rate

125 kbit/s / 250 kbit/s / 500 kbit/s / 1 Mbit/s

5 VDC

±5%, module-internal, max. 300 mA

24 VDC

Module-internal, max. 300 mA

Electrical isolation

Bus isolated from encoder and channel

Channel not isolated from channel and encoder

Horizontal

Yes

Vertical

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

-25 to 60°C

Vertical mounting orientation

-25 to 50°C

Derating

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

5 to 95%, non-condensing

Note

Order 1x terminal block X20TB12 separately.
Order 1x bus module X20BM11 separately.

Pitch

12.5+0.2 mm