Fast delivery within 72 Hours

B&R X20cSL8101

openSAFETY manager for up to 280 SafeNODEsFlexibly programmable using Automation Studio / SafeDESIGNERInnovative management of safe machine options (SafeOPTION)Parameter and configuration management…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

openSAFETY manager for up to 280 SafeNODEsFlexibly programmable using Automation Studio / SafeDESIGNERInnovative management of safe machine options (SafeOPTION)Parameter and configuration management

The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3.In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed by the SafeLOGIC controller.

Specification

Interfaces

POWERLINK

System module

CPU

B&R ID code

0xE926

Cooling

Fanless

Status indicators

CPU function, POWERLINK, SafeKEY

CPU function

Yes, using LED status indicator

SafeKEY

Yes, using LED status indicator

Dynamic node allocation (DNA)

Yes

Scope

Network segment

Function

Programmable

Standalone mode

Yes

Power consumption

5.3 W

Internal I/O

0.6 W

Additional power dissipation caused by actuators (resistive) [W]

Fieldbus - I/O

Yes

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

Functional safety

EN 50156-1:2004

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

DNV

Temperature: A (0 to 45°C)
Humidity: B (up to 100%)
Vibration: A (0.7 g)
EMC: B (bridge and open deck)

LR

ENV1

KR

Yes

ABS

Yes

BV

EC21B
Temperature: 5 – 45°C
Vibration: 0.7 g
EMC: Bridge and open deck

Note

Order SafeKEY and SafeLOGIC range of functions using the X20MK configurator.
X20 end cover plate (right) included in delivery
12-pin X20 terminal block, safety-keyed, included in delivery
SafeKEY cover included in delivery

FB instances

4096

Marker memory

262,144 bytes

Stack memory

32,768 bytes

Memory for safe input data

6144 bytes

Memory for safe output data

2048 bytes

Memory for standard input data

1024 bytes

Memory for standard output data

1024 bytes

Marker count

16,382

Max. number of function block types

512

Max. number of force variables

64

Max. number of variable with variable status

1023

Input voltage

24 VDC -15% / +20%

Input current

Max. 0.9 A

Fuse

Required line fuse: Max. 10 A, slow-blow

Reverse polarity protection

Yes

Nominal output power

7 W

Parallel connection

Yes

Redundant operation

Yes

Overload characteristics

Short-circuit proof, temporary overload

Nominal output voltage

24 VDC

Behavior on short circuit

Required line fuse

Permissible contact load

10 A

Fieldbus

200 µs

Variant

2x shielded RJ45 port (hub)

Line length

Max. 100 m between 2 nodes (segment length)

Transfer rate

100 Mbit/s

Physical layer

100BASE-TX

Half-duplex

Yes

Full-duplex

No

Autonegotiation

Yes

Auto-MDI/MDIX

Yes

Synchronization between bus systems possible

Yes

Horizontal

Yes

Vertical

Yes

Installation elevation above sea level

0 to 2000 m, no limitation

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

-25 to 60°C

Vertical mounting orientation

-25 to 45°C

Derating

See section "Derating".

Starting temperature

Yes, -40°C

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

Up to 100%, condensing

Width

62.5+0.2 mm

Height

99 mm

Depth

75 mm

Weight

190 g

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20cSL8101”

Your email address will not be published. Required fields are marked *