Fast delivery within 72 Hours
B&R X20CP1301
Intel x86 200 MHz compatible with integrated I/O processorOnboard Ethernet and USB1 slot for modular interface expansion30 digital inputs/outputs and 2 analog inputs integrated in the device1 GB onboa…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Intel x86 200 MHz compatible with integrated I/O processorOnboard Ethernet and USB1 slot for modular interface expansion30 digital inputs/outputs and 2 analog inputs integrated in the device1 GB onboard flash drive128 MB DDR3 SDRAMFanlessNo batteryBacked-up real-time clock
The X20 Compact controller series is characterized by 3 integrated I/O modules. The device is equipped with 30 different digital inputs/outputs and 2 analog inputs. 1 analog input can be used for Pt1000 resistance temperature measurement. The X20CP1301 is equipped with an Intel x86 200 MHz compatible processor, 128 MB RAM and 1 GB built-in flash drive. The FRAM for storing remanent variables has 16 kB available. A fanless and battery-free design ensures maintenance-free operation. The controller is equipped with one Ethernet, one USB and one RS232 interface. Various bus and network systems can be flexibly integrated into the X20 system via a freely usable slot for X20 communication modules.
Specification
| Interfaces |
1x RS232, 1x Ethernet, 1x USB, 1x X2X Link |
|---|---|
| System module |
Controller |
| B&R ID code |
0xE35B |
| Cooling |
Fanless |
| Status indicators |
CPU function, Ethernet, RS232, PLC power supply, I/O power supply, I/O function per channel |
| Outputs |
Digital outputs: Yes, using LED status indicator and software (output error status) |
| CPU function |
Yes, using LED status indicator |
| RS232 data transfer |
Yes, using LED status indicator |
| Inputs |
Analog inputs: Yes, using LED status indicator and software |
| Ethernet |
Yes, using LED status indicator |
| I/O power supply |
Yes, using LED status indicator |
| Supply voltage monitoring |
Yes, using LED status indicator |
| Temperature |
Yes, using software register |
| Controller redundancy |
No |
| ACOPOS support |
Yes |
| ReACTION-capable I/O channels |
No |
| Visual Components support |
Yes |
| Power consumption without interface module and USB |
4.3 W |
| Power consumption for X2X Link power supply |
0.8 W |
| Internal I/O |
2.3 W |
| Additional power dissipation caused by actuators (resistive) [W] |
– |
| Type of signal lines |
Shielded lines must be used for all high-speed digital inputs/outputs, line length: Max. 20 m |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
Evaluation ongoing |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc |
| UL |
cULus E115267 |
| HazLoc |
cCSAus 244665 |
| DNV |
Temperature: B (0 to 55°C) |
| CCS |
Yes |
| LR |
ENV1 |
| KR |
Yes |
| ABS |
Yes |
| BV |
EC33B |
| Input voltage |
24 VDC -15% / +20% |
| Input current |
Max. 1 A |
| Fuse |
Required line fuse: Max. 10 A, slow-blow |
| Reverse polarity protection |
Yes |
| Nominal output power |
2 W |
| Parallel connection |
Yes |
| Redundant operation |
Yes |
| Nominal output voltage |
24 VDC |
| Permissible contact load |
10 A |
| Real-time clock |
Retention for at least 300 hours, typ. 1000 hours at 25°C, 1 s resolution, -18 to 28 ppm accuracy at 25°C |
| FPU |
Yes |
| Type |
USB 1.1/2.0 |
| Clock frequency |
200 MHz |
| Data code |
16 kB |
| Program code |
16 kB |
| L2 cache |
128 kB |
| Integrated I/O processor |
Processes I/O data points in the background |
| Modular interface slots |
1 |
| Remanent variables |
16 kB FRAM, retention >10 years |
| Shortest task class cycle time |
2 ms |
| Typical instruction cycle time |
0.0419 µs |
| RAM |
128 MB DDR3 SDRAM |
| Data retention |
10 years |
| Guaranteed |
40 TB |
| Results for 5 years |
21.9 GB/day |
| Guaranteed erase/write cycles |
20,000 |
| Error-correcting code (ECC) |
Yes |
| Signal |
Ethernet |
| Variant |
Standard outputs and mixed channels: Current-sourcing FET |
| Max. distance |
900 m |
| Transfer rate |
10/100 Mbit/s |
| Line length |
Max. 100 m between 2 stations (segment length) |
| Physical layer |
10BASE-T/100BASE-TX |
| Half-duplex |
Yes |
| Full-duplex |
Yes |
| Autonegotiation |
Yes |
| Auto-MDI/MDIX |
Yes |
| Max. output current |
0.5 A |
| Fieldbus |
X2X Link master |
| Quantity |
4 standard outputs, 4 high-speed outputs and 4 mixed channels, configuration as input or output using software |
| Nominal voltage |
24 VDC |
| Input current at 24 VDC |
X1 – Standard inputs: Typ. 3.5 mA |
| Input circuit |
Sink |
| Hardware |
Standard inputs and mixed channels: ≤200 μs |
| Software |
Default 1 ms, configurable between 0 and 25 ms in 0.1 ms increments |
| Connection type |
1-wire connections |
| Input resistance |
X1 – Standard inputs: 6.8 kΩ |
| Additional functions |
X2 – High-speed digital inputs: |
| Low |
<5 VDC |
| High |
>15 VDC |
| Encoder inputs |
24 V, asymmetrical |
| Counter size |
32-bit |
| Input frequency |
Max. 10 kHz |
| Evaluation |
1x |
| Encoder power supply |
Module-internal, max. 300 mA |
| Overload characteristics of encoder power supply |
Short-circuit proof, overload-proof |
| Signal form |
Square wave pulse |
| Counter frequency |
250 kHz |
| Possible measurements |
Period measurement, gate measurement, differential time measurement, edge counter, edge times |
| Measurements per module |
Each function up to 2x |
| Timestamp |
1 µs resolution |
| Input |
Resistance measurement with constant current supply for 2-wire connections |
| Input type |
Differential input |
| Voltage |
<0.025% |
| Current |
<0.05% |
| Conversion time |
Only temperature input enabled: 200 µs |
| Data type |
INT |
| Input protection |
Protection against wiring with supply voltage |
| Output of digital value during overload |
Configurable |
| Conversion procedure |
SAR |
| Input filter |
First-order low-pass filter / cutoff frequency 7 Hz |
| Gain |
0.3% (Rev. <C0: 1.93%) |
| Offset |
0.15% (Rev. <C0: 0.32%) |
| DC |
70 dB |
| 50 Hz |
>60 dB |
| Common-mode range |
1 V |
| Crosstalk between channels |
<-70 dB |
| Digital converter resolution |
13-bit |
| Output format |
INT or UINT for resistance measurement |
| Pt1000 |
-200 to 850°C |
| Resistance measurement range |
0.1 to 4000 Ω |
| Temperature sensor resolution |
1 LSB = 0x0005 = 0.16°C |
| Resistance measurement resolution |
1 LSB = 0x0005 = 0.49 Ω |
| Sensor standard |
EN 60751 |
| Linearization method |
Internal |
| Measuring current |
1 mA |
| Permissible input signal |
Short-term max. ±30 V |
| Max. gain drift |
0.023 %/°C |
| Max. offset drift |
0.012%/°C |
| Nonlinearity |
<0.05% |
| Standardized range of values for resistance measurement |
0.1 to 4000.0 Ω |
| Switching voltage |
24 VDC -15% / +20% |
| Nominal output current |
Standard outputs and mixed channels: 0.5 A |
| Total nominal current |
Standard outputs and mixed channels: 4 A |
| Output circuit |
Standard outputs and mixed channels: Source |
| Output protection |
Thermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current") |
| Period duration |
5 to 65535 µs corresponds to 200 kHz to 15 Hz |
| Pulse duration |
0 to 100%, minimum 2.5 µs |
| Resolution for pulse duration |
0.1% of the configured frequency |
| Diagnostic status |
Standard outputs and mixed channels: Output monitoring with 10 ms delay |
| Leakage current when the output is switched off |
Standard outputs and mixed channels: 5 µA |
| RDS(on) |
140 mΩ |
| Residual voltage |
Standard outputs and mixed channels: <0.1 V at nominal current 0.5 A |
| Peak short-circuit current |
Standard outputs and mixed channels: <3 A |
| Switch-on in the event of overload shutdown or short-circuit shutdown |
Standard outputs and mixed channels: Approx. 10 ms (depends on module temperature) |
| 0 → 1 |
Standard outputs and mixed channels: <300 µs |
| 1 → 0 |
Standard outputs and mixed channels: <300 µs |
| Resistive load |
Standard outputs and mixed channels: Max. 500 Hz |
| Inductive load |
See section "Switching inductive loads". |
| Braking voltage when switching off inductive loads |
Standard outputs and mixed channels: Typ. 45 VDC |
| Electrical isolation |
Ethernet (IF2) and X2X (IF6) isolated from each other, from other interfaces and from PLC |
| Horizontal |
Yes |
| Vertical |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Horizontal mounting orientation |
-25 to 60°C |
| Vertical mounting orientation |
-25 to 50°C |
| Derating |
See section "Switching frequency derating for high-speed digital outputs". |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
5 to 95%, non-condensing |
| Note |
X20 end cover plate (right) included in delivery |
| Width |
164 mm |
| Height |
99 mm |
| Depth |
75 mm |
| Weight |
300 g |

Reviews
Clear filtersThere are no reviews yet.