Fast delivery within 72 Hours
B&R X20CM8281
€ 94,34 – € 291,50Price range: € 94,34 through € 291,50
Digital and analog channelsSelectable current and voltage for AI and AOCounter functions
The module is a universal mixed module. On this module, digital I/…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Digital and analog channelsSelectable current and voltage for AI and AOCounter functions
The module is a universal mixed module. On this module, digital I/O and analog I/O are combined. A current or voltage signal can be used for the analog I/O as desired. Counter functions on two of the digital inputs expand the range of use.
Specification
| I/O module | 4 digital inputs, 2 digital outputs, 1 analog input, 1 analog output, special functions |
|---|---|
| B&R ID code | 0x24C3 |
| Status indicators | I/O function per channel, operating state, module status |
| Module run/error | Yes, using LED status indicator and software |
| Analog inputs | Yes, using LED status indicator and software |
| Digital outputs | Yes, using LED status indicator and software (output error status) |
| Bus | 0.01 W |
| Internal I/O | 1.75 W |
| Additional power dissipation caused by actuators (resistive) [W] | – |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X |
| UL | cULus E115267 Industrial control equipment |
| HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| DNV | Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| CCS | Yes |
| LR | ENV1 |
| KR | Yes |
| ABS | Yes |
| BV | EC33B Temperature: 5 – 55°C Vibration: 4 g EMC: Bridge and open deck |
| KC | Yes |
| Quantity | 1 |
| Nominal voltage | 24 VDC |
| Input characteristics per EN 61131-2 | Type 1 |
| Input voltage | 24 VDC -15% / +20% |
| Input current at 24 VDC | Typ. 3.3 mA |
| Input circuit | Sink |
| Hardware | ≤2 µs |
| Software | Default 1 ms, configurable between 0 and 25 ms in 0.2 ms increments |
| Connection type | 1-wire connections |
| Input resistance | Typ. 7.18 kΩ |
| Additional functions | 20 kHz event counting, gate measurement |
| Low | <5 VDC |
| High | >15 VDC |
| Insulation voltage between channel and bus | 500 Veff |
| Signal form | Square wave pulse |
| Evaluation | Positive edge – Negative edge |
| Input frequency | Max. 20 kHz |
| Counter 1 | Input 1 |
| Counter 2 | Input 3 |
| Counter frequency | Max. 20 kHz |
| Counter size | 16-bit |
| Internal | 48 MHz, 24 MHz, 12 MHz, 6 MHz, 3 MHz, 1.5 MHz, 750 kHz, 375 kHz, 187.5 kHz |
| Length of pause between pulses | ≥100 µs |
| Pulse length | ≥20 µs |
| Supported inputs | Input 4 |
| Input | ±10 V or 0 to 20 mA / 4 to 20 mA, via different terminal connections |
| Input type | Single-ended |
| Voltage | Max. 0.02%, from 10 MΩ → 1 kΩ, resistive |
| Current | Max. 0.5%, from 1 Ω → 400 Ω, resistive |
| Conversion time | 300 µs, conversion runs asynchronous to the X2X Link cycle |
| Output format | INT |
| Input protection | Protection against wiring with supply voltage |
| Conversion procedure | Successive approximation |
| Input filter | Second-order low-pass filter / Cutoff frequency 1 kHz |
| Gain | 0.05% |
| Offset | 0.125% |
| Variant | Current-sourcing FET |
| Switching voltage | 24 VDC -15% / +20% |
| Nominal output current | 0.5 A |
| Total nominal current | 1 A |
| Output circuit | Source |
| Output protection | Short-circuit proof |
| Diagnostic status | Output monitoring with 10 ms delay |
| Leakage current when the output is switched off | 5 µA |
| RDS(on) | 105 mΩ |
| Peak short-circuit current | <14 A |
| Switch-on in the event of overload shutdown or short-circuit shutdown | Approx. 10 ms (depends on the module temperature) |
| 0 → 1 | <250 µs |
| 1 → 0 | <270 µs |
| Resistive load | Max. 100 Hz |
| Inductive load | See section “Switching inductive loads”. |
| Braking voltage when switching off inductive loads | Typ. 50 VDC |
| Output | ±10 V or 0 to 20 mA, via different terminal connections |
| Digital converter resolution | 12-bit |
| Settling time on output change over entire range | 1 ms |
| Switch on/off behavior | Internal enable relay for startup and errors |
| Nonlinearity | <0.1% |
| Electrical isolation | Channel isolated from bus Channel not isolated from channel |
| Horizontal | Yes |
| Vertical | Yes |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
| Horizontal mounting orientation | -25 to 60°C |
| Vertical mounting orientation | -25 to 50°C |
| Derating | See section “Derating”. |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
| Operation | 5 to 95%, non-condensing |
| Note | Order 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately. |
| Pitch | 12.5+0.2 mm |
| Condition | New, Used |
| Revision | Rev. G0, Rev. I0 |
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “B&R X20CM8281” Cancel reply

Reviews
Clear filtersThere are no reviews yet.