B&R X20CM0985-1

Energy measurement for 120 to 480 VACSimultaneous measurement of 2 AC mains networks plus 2 additional voltagesFor multifunctional measurement tasksIntelligent mains synchronization unit…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Energy measurement for 120 to 480 VACSimultaneous measurement of 2 AC mains networks plus 2 additional voltagesFor multifunctional measurement tasksIntelligent mains synchronization unit

The module has a compact size and combines a power measurement module that has special features with a synchronization unit that is able to meet all demands.The measurement unit’s 3 current inputs are suitable for both X: 1 A and X: 5 A current transformers. Overcurrent resistance and the high resolution of the measurement unit round off its features. For the voltage inputs, the value range can be configured between 480 VAC and 120 VAC. The area of use includes 4-wire AC networks with a phase voltage up to 480 VAC and 3-wire systems, whereas L2 can be grounded (V-connection). The module can also handle Aron measuring circuits. The resulting measured values include the pure phase current; line-to-line voltage or phase voltage; the effective, reactive and apparent power parts; the mains frequency; the power factor and much more. In addition, peak values and energy meters are stored on the module in nonvolatile memory. Depending on the configuration, it is also possible to use a digital output as a pulse encoder for an external energy meter. The synchronization unit doesn’t just take the phasing and phase voltage into consideration; integrated intelligence also monitors the rate of change and other parameters, allowing them to influence when the synchronization output is switched. It is also possible to monitor a generator using a large number of additional conditions. A total of 4 voltage inputs provide substantial overall flexibility. Monitoring functions expand the features of the module. Dependent overcurrent monitoring is included, which utilizes the thermal capacity of the motor/generator to allow short overloads while still providing full protection. The dependent, delayed imbalanced load monitoring used to protect three-phase generator and three-phase networks from imbalanced load can be adapted to the characteristics of different generator types using parameters while taking their special thermal time constants into account.

Specification

I/O moduleX20 energy measurement and synchronization module
B&R ID code0xB768
Status indicatorsChannel status, operating state, module status
Module run/errorYes, using LED status indicator and software
Analog inputsYes, using LED status indicator (measurement range of analog inputs)
Digital outputsYes, using LED status indicator and software
Overvoltage categoryll
Measurement range15.2 Hz to 2x nominal frequency
Accuracy<10 mHz at 400 V ±5% or 100 V ±5%
Bus1.05 W
Internal I/O4 W
Additional power dissipation caused by actuators (resistive) [W]
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
CCSYes
LRENV1
KRYes
ABSYes
BVEC33B Temperature: 5 – 55°C Vibration: 4 g EMC: Bridge and open deck
KCYes
UL 6200Rev. D0 Hardware upgrade 2.5.0.0
Quantity1
VariantRelay / Changeover contact
Nominal voltage30 VDC / 240 VAC
Switching voltageMax. 60 VDC / 250 VAC
Nominal output current1 A at 30 VDC / 1 A at 240 VAC
Total nominal current0.5 A
Connection type1-wire connections
Output circuitSource
Output protectionThermal shutdown in the event of overcurrent or short circuit
Diagnostic statusOutput monitoring with 10 ms delay
Leakage current when the output is switched off5 μA
Residual voltage<0.3 V at 0.1 A nominal current
Peak short-circuit current<2 A
Switch-on in the event of overload shutdown or short-circuit shutdownApprox. 10 ms, depends on the module temperature
0 → 1≤10 ms
1 → 0≤10 ms
Resistive loadMax. 100 Hz
Insulation voltage between channel and bus500 Veff
Rated frequencyDC / 45 to 63 Hz
Min.10 mA / 5 VDC
Max.30 W / 240 VAC
Actuator power supplyExternal
MechanicalMin. 10 x 106 ops.
ElectricalMin. 60 x 103 ops. (NC) at 1 A Min. 30 x 103 ops. (NO) at 1 A
Contact resistanceMax. 100 mΩ
InternalNone
ExternalNone
DCInverse diode, RC combination or VDR
ACRC combination or VDR
Channel - Channel1000 VAC / 1 min
Channel - Bus4000 VAC / 1 min
Channels3
Input1 A / 5 A AC
Input typeIsolated current transformer according to the compensation principle with a magnetic sensor, for connecting an external transformer
Digital converter resolution±15-bit
50 Hz10 ms
60 Hz8.33 ms
Permissible input signalMax. 1.5 A / 7.7 A
±120 VAC1 LSB = 0x0001 = 5.707 mV
±480 VAC1 LSB = 0x0001 = 22.787 mV
Overshoot0x7FFF
Undershoot0x8001
Conversion methodSAR
Cutoff frequency10 kHz
Slope60 dB
Maximum gain drift0.07% per °C
Maximum offset driftMeasurement range 2 A: 0.0064% per °C, measurement range 10 A: 0.00384% per °C
Crosstalk between channels-70 dB
Nonlinearity≤0.5% at 45 to 65 Hz
Protection against electric shockProtective impedance per EN 61131-2
Test voltage between channel and bus (type test)3700 Veff
Output formatINT
Input impedance in signal rangeApprox. 3 MΩ
Gain0.2%
Offset0.05%
Input protectionOvervoltage protection
±1 A1 LSB = 0x0001 = 189.903 μA
±5 A1 LSB = 0x0001 = 949.513 μA
Thermal overcurrent15 x INom for 0.2 s
Monitored overcurrent4 x INom
Measurement range 1 AMax. 30 mΩ
Measurement range 5 AMax. 10 mΩ
Electrical isolationBus isolated from I/O power supply and digital inputs and outputs Digital inputs and outputs isolated from each other
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
DeratingSee section “Derating”.
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing
NoteOrder 2x terminal block X20TB12 separately. Order 2x screw clamp terminal block TB3102 and 2x screw clamp terminal block TB3104 separately.
Pitch87.5+0.2 mm