Specification

I/O module

8 digital inputs 24 VDC for 1-wire connections, 4 digital outputs 24 VDC for 1-wire connections

Nominal voltage

24 VDC

B&R ID code

0xE225

Status indicators

I/O function per channel, operating state, module status

Module run/error

Yes, using LED status indicator and software

Outputs

Yes, using LED status indicator and software (output error status)

Bus

0.21 W

Internal I/O

0.5 W

Additional power dissipation caused by actuators (resistive) [W]

+0.21

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

Input characteristics per EN 61131-2

Type 1

Input voltage

24 VDC -15% / +20%

Input current at 24 VDC

Typ. 3.75 mA

Input circuit

Sink

Hardware

≤100 µs

Software

Default 1 ms, configurable between 0 and 25 ms in 0.2 ms increments

Connection type

1-wire connections

Input resistance

Typ. 6.4 kΩ

Low

<5 VDC

High

>15 VDC

Insulation voltage between channel and bus

500 Veff

Variant

Current-sourcing FET

Switching voltage

24 VDC -15% / +20%

Nominal output current

0.5 A

Total nominal current

2 A

Output circuit

Source

Output protection

Thermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current")
Internal freewheeling diode for switching inductive loads (see section "Switching inductive loads")

Diagnostic status

Output monitoring with 10 ms delay

Leakage current when the output is switched off

5 µA

RDS(on)

210 mΩ

Peak short-circuit current

<12 A

Switch-on in the event of overload shutdown or short-circuit shutdown

Approx. 10 ms (depends on the module temperature)

0 → 1

<300 µs

1 → 0

<300 µs

Resistive load

Max. 500 Hz

Inductive load

See section "Switching inductive loads".

Braking voltage when switching off inductive loads

Typ. 50 VDC

Electrical isolation

Channel isolated from bus
Channel not isolated from channel

Horizontal

Yes

Vertical

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

-25 to 60°C

Vertical mounting orientation

-25 to 50°C

Derating

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

Up to 100%, condensing

Note

Order 1x terminal block X20TB12 separately.
Order 1x bus module X20cBM11 separately.

Pitch

12.5+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20cDM9324”

Your email address will not be published. Required fields are marked *