Fast delivery within 72 Hours
B&R X20cDI4375
4 digital inputsSink connection3-wire connections24 VDC and GND for sensor supplyOpen circuit and short circuit detection, can be switched off individually for each channelSoftware input filter can be…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
4 digital inputsSink connection3-wire connections24 VDC and GND for sensor supplyOpen circuit and short circuit detection, can be switched off individually for each channelSoftware input filter can be configured for entire module
The module is equipped with 4 inputs for 3-wire connections. It has open circuit and short circuit detection. This detection can be switched off individually for each channel.
Specification
| I/O module |
4 digital inputs 24 VDC for 3-wire connections, open-circuit and short-circuit detection, possible to switch off detection for each channel |
|---|---|
| B&R ID code |
0xE220 |
| Status indicators |
I/O function per channel, operating state, module status, sensor line, sensor power supply |
| Module run/error |
Yes, using LED status indicator and software |
| Open circuit |
Yes, using LED status indicator and software |
| Short circuit |
Yes, using LED status indicator and software |
| Sensor power supply |
4x 50 mA |
| Other channel errors |
Yes, using LED status indicator and software |
| Bus |
0.01 W |
| Internal I/O |
1.1 W |
| Additional power dissipation caused by actuators (resistive) [W] |
– |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 GcIP20, Ta (see X20 user's manual)FTZÚ 09 ATEX 0083X |
| UL |
cULus E115267Industrial control equipment |
| HazLoc |
cCSAus 244665Process control equipmentfor hazardous locations Class I, Division 2, Groups ABCD, T5 |
| DNV |
Temperature: B (0 to 55°C)Humidity: B (up to 100%)Vibration: B (4 g)EMC: B (bridge and open deck) |
| LR |
ENV1 |
| KR |
Yes |
| ABS |
Yes |
| BV |
EC33BTemperature: 5 – 55°CVibration: 4 gEMC: Bridge and open deck |
| Nominal voltage |
24 VDC |
| Input voltage |
24 VDC -15% / +20% |
| Input current at 24 VDC |
Typ. 4.8 mA (standard wiring) |
| Input circuit |
Sink |
| Hardware |
0.8 ms |
| Software |
Default 1 ms, configurable between 0 and 25 ms in 0.2 ms increments |
| Connection type |
3-wire connections |
| Open-circuit and short-circuit detection |
Yes, possible to switch off for each channel |
| Electrical isolation |
Channel isolated from busChannel not isolated from channel |
| Horizontal |
Yes |
| Vertical |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Horizontal mounting orientation |
-25 to 60°C |
| Vertical mounting orientation |
-25 to 50°C |
| Derating |
– |
| Starting temperature |
Yes, -40°C |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
Up to 100%, condensing |
| Note |
Order 1x terminal block X20TB12 separately.Order 1x bus module X20cBM11 separately. |
| Pitch |
12.5+0.2 mm |

Reviews
Clear filtersThere are no reviews yet.