Fast delivery within 72 Hours

B&R X20cCMR011

Measurement and evaluation of the ambient conditions in the control cabinetRecording ambient conditionsRecording operating hours and power-on cyclesSaving user data directly on the moduleSupports blac…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

Measurement and evaluation of the ambient conditions in the control cabinetRecording ambient conditionsRecording operating hours and power-on cyclesSaving user data directly on the moduleSupports blackout mode2 inputs for PT1000 temperature sensors2 digital inputs 24 VDC1 digital output 24 VDC

The module is designed for measuring ambient conditions in the control cabinet as well as recording operating hours and power-on cycles. In addition, the module offers the option of storing user data directly on the module, is equipped with inputs/outputs and supports blackout mode.Measuring and evaluating ambient conditionsThe ambient conditions are continuously evaluated by the module. The duration in which individual parameters are within certain ranges is stored internally. This makes it possible, for example, to determine how long the system remained in a certain temperature range. The histograms recorded by the module can be read out by the user.Internal module memory for user dataWith 512 kB nonvolatile user memory (flash), data from the application can be saved directly on the module and also read back from the module. The data is therefore retained after the module or CPU is restarted and remains with the module in the event that the module is connected to another machine or system, for example. Data retention is maintenance-free – without batteries.Inputs/OutputsThe module is equipped with 2 inputs for Pt1000 temperature sensors, 2 digital inputs (24 VDC) and 1 digital output (24 VDC).Blackout modeThe integrated blackout mode ensures that module functionality is maintained even in the event of network failure.

Specification

I/O module

Measurement of ambient conditions:
Temperature in the module, relative humidity, vibration, shock, position, operating hours, power-on cycles
2 digital inputs, 1 digital output, 2 Pt1000 temperature inputs

B&R ID code

0x2A02

Status indicators

I/O function per channel, overload, memory access, operating state, module status

Module run/error

Yes, using LED status indicator and software

Output

Yes, using LED status indicator and software (output error status)

Scope

Module

Function

Module functionality

Standalone mode

No

Bus

0.4 W

Internal I/O

0.1 W

Additional power dissipation caused by actuators (resistive) [W]

+0.075

Type

512 kB flash memory

Sectors

8 sectors, 64 kB each

Data retention

20 years at 55°C

Guaranteed erase/write cycles

100,000 per sector

Error-correcting code (ECC)

No

Write protection

No

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

DNV

Temperature: B (0 to 55°C)
Humidity: B (up to 100%)
Vibration: B (4 g)
EMC: B (bridge and open deck)

LR

ENV1

KR

Yes

ABS

Yes

Quantity

1

Nominal voltage

24 VDC

Input voltage

24 VDC -15% / +20%

Input current at 24 VDC

Typ. 3.75 mA

Input circuit

Sink

Hardware

≤100 μs

Software

Default 1 ms, configurable between 0 and 25 ms in 0.2 ms increments

Connection type

1- or 2-wire connections

Input resistance

Typ. 6.4 kΩ

Low

<5 VDC

High

>15 VDC

Insulation voltage between channel and bus

500 Veff

Input

Resistance measurement for 2-wire connections

Digital converter resolution

12-bit

Filter time

Configurable

Conversion time

1 ms for all inputs

Output format

INT

Pt1000

1 LSB = 0.1°C

Input filter

Averaging with clipping function

Linearization method

Internal

Permissible input signal

Short-term ±15 V

Max. gain drift

0.0003 %/°C

Max. offset drift

0.06 %/°C

Nonlinearity

<0.010%

Range undershoot

0x8001

Range overshoot

0x7FFF

Open circuit

0x7FFF

General fault

0x8000

Open inputs

0x7FFF

Sensor position

Module-internal

Sampling rate

Typ. 10 ms

Measurement range

±2000 dps

Resolution

±70 mdps per LSB

Max. error

±2% at 10 to 80% relative humidity
±3% at <10 and >80% relative humidity

Linearity over temperature

±1.5% at -40 to 85°C

Offset calibration error

±10 dps

Variant

Current-sourcing FET

Switching voltage

24 VDC -15% / +20%

Nominal output current

0.5 A

Output circuit

Source

Diagnostic status

Output monitoring with 10 ms delay

Leakage current when the output is switched off

120 µA

RDS(on)

300 mΩ

0 → 1

<300 µs

1 → 0

<300 µs

Resistive load

Max. 100 Hz

Inductive load

See section "Switching inductive loads".

Short-circuit proof

Yes

Overload-proof

Temporary overload

Electrical isolation

Analog channel not isolated from bus
Digital channel isolated from bus
Digital channel not isolated from digital channel

Horizontal

Yes

Vertical

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

-25 to 60°C

Vertical mounting orientation

-25 to 50°C

Derating

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

Up to 100%, condensing

Note

Order 1x terminal block X20TB12 separately.
Order 1x bus module X20cBM11 separately.

Pitch

12.5+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20cCMR011”