Fast delivery within 72 Hours

B&R X20cCM4810

4-channel vibration measurement and analysis module24-bit resolution at 51.562 kHzIEPE supplyInternal calculation of an extensive range of condition parametersData buffer upload…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

4-channel vibration measurement and analysis module24-bit resolution at 51.562 kHzIEPE supplyInternal calculation of an extensive range of condition parametersData buffer upload

This compact module provides a system for measuring and analyzing vibrations for use in applications such as condition monitoring for machinery and equipment. The measurement unit consists of 4 vibration inputs with 24-bit converter resolution and a sampling frequency of 51.562 kHz. Each of the inputs has a separately activated constant current source to supply IEPE sensors. Signal conditioning algorithms integrated in the module include configurable high and low-pass filters, an envelope curve generator and a Fourier transform, among many others. Various characteristic values and configurable frequency bands are available to ensure seamless signal evaluation. The module-internal calculation minimizes the load on the bus and PLC. Whether used for traditional condition monitoring or as a means of process optimization, the maximum evaluable frequency of 10 kHz and maximum frequency resolution of under 63 mHz make it suitable for almost any application. If desired, it can also be used as a standard input module. The ability to upload all values in the time and frequency domain also allow measurements to be evaluated externally or archived.

Specification

I/O module

X20 4-channel analog input module for vibration measurement and analysis of condition monitoring tasks

Insulation voltage between channel and bus

500 Veff

Nominal voltage

24 VDC ±20%

B&R ID code

0xE7F0

Status indicators

Run, error, vibration inputs 1 to 4

Module run/error

Yes, using LED status indicator and software

Bus

0.01 W

Internal I/O

2.5 W

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

Quantity

4

Input type

IEPE sensor: Acceleration

Digital converter resolution

24-bit

Per channel

Yes

At minimum supply voltage

Starting at 17 V (or greater) for more than 1 ms

At nominal supply voltage

Starting at 21.3 V (or greater) for more than 1 ms

At maximum supply voltage

Starting at 25.5 V (or greater) for more than 1 ms

Permissible input signal

±10 VAC

Conversion procedure

Sigma-delta

Type

Vibration input

Sampling frequency

51.5625 kHz

Input high pass cutoff frequency

34 mHz

Input low pass cutoff frequency

19.75 kHz

Downsampling

200 Hz, 500 Hz, 1 kHz, 2 kHz, 5 kHz, 10 kHz (configurable)

Frequency resolution of spectra

0.0629 Hz, 0.1574 Hz, 0.3147 Hz, 0.6294 Hz, 1.5736 Hz, 3.1471 Hz

Sensor power supply

IEPE, 5 mA constant current source (4.9 – 5.5 mA), can be switched off for each channel

Electrical isolation

Channel isolated from bus

Channel not isolated from channel

Horizontal

Yes

Vertical

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

-25 to 50°C

Vertical mounting orientation

-25 to 45°C

Derating

See section "Derating".

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

Up to 100%, condensing

Note

Order 1x terminal block X20TB12 separately.
Order 1x bus module X20cBM31 separately.

Pitch

25+0.2 mm