B&R X20BT9400
X2X Link bus transmitterFor seamless expansion of the systemUp to 100 m segment lengthSupply for internal I/O power supplyIntegrated X2X Link power supply of the X67 systemOperation only on the rightm…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
X2X Link bus transmitterFor seamless expansion of the systemUp to 100 m segment lengthSupply for internal I/O power supplyIntegrated X2X Link power supply of the X67 systemOperation only on the rightmost slot
To connect an X20 system to an X67 system, a bus transmitter is simply connected to the end of the X20 block so that the X2X Link cable can be clamped. The bus transmitter also provides the X2X Link supply voltage of the X67 system. The X67 system power supply module that was previously always necessary can be omitted.The bus transmitter module is only permitted to be operated with a bus module where the internal I/O power supply is connected through (e.g. X20BM11). If the supply is used for the internal I/O power supply, this potential group is not permitted to be supplied by any other module. An I/O module with bus module X20BM01 must be used to isolate the potential group.
Specification
| Bus transmitter |
X2X Link bus transmitter with supply for I/O and integrated X67 system power supply |
|---|---|
| B&R ID code |
0xA238 |
| Status indicators |
X2X bus function, operating state, module status |
| Module run/error |
Yes, using LED status indicator and software |
| X2X bus function |
Yes, using LED status indicator |
| Power consumption for X2X Link power supply |
1.38 W |
| Bus |
0.5 W |
| As bus transmitter |
0.1 W |
| Additionally as supply module |
0.6 W |
| Additional power dissipation caused by actuators (resistive) [W] |
– |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc |
| UL |
cULus E115267 |
| HazLoc |
cCSAus 244665 |
| KC |
Yes |
| Input voltage |
24 VDC -15% / +20% |
| Input current |
Max. 0.5 A |
| Fuse |
Required line fuse: Max. 10 A, slow-blow |
| Reverse polarity protection |
No |
| Parallel connection with X67PS1300 |
Yes |
| Overload characteristics |
Temporarily short-circuit and overload-proof |
| Horizontal mounting orientation |
-25 to 60°C |
| Vertical mounting orientation |
-25 to 50°C |
| Nominal output voltage |
24 VDC |
| Behavior on short circuit |
Required line fuse |
| Permissible contact load |
10 A |
| Horizontal |
Yes |
| Vertical |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Derating |
– |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
5 to 95%, non-condensing |
| Note |
Order 1x terminal block X20TB12 separately. |
| Pitch |
12.5+0.2 mm |