B&R X20BT9100
X2X Link bus transmitterFor seamless expansion of the systemUp to 100 m segment lengthSupply for internal I/O power supplyOperation only on the rightmost slot…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
X2X Link bus transmitterFor seamless expansion of the systemUp to 100 m segment lengthSupply for internal I/O power supplyOperation only on the rightmost slot
The bus transmitter is used for seamless expansion of the X20 system. Stations can be up to 100 m apart.The bus transmitter module is only permitted to be operated with a bus module where the internal I/O power supply is connected through (e.g. X20BM11). If the supply is used for the internal I/O power supply, this potential group is not permitted to be supplied by any other module. An I/O module with bus module X20BM01 must be used to isolate the potential group.
Specification
| Bus transmitter |
X2X Link bus transmitter with supply for I/O |
|---|---|
| B&R ID code |
0x1BC2 |
| Status indicators |
X2X bus function, operating state, module status |
| Module run/error |
Yes, using LED status indicator and software |
| X2X bus function |
Yes, using LED status indicator |
| Bus |
0.5 W |
| As bus transmitter |
0.1 W |
| Additionally as supply module |
0.6 W |
| Additional power dissipation caused by actuators (resistive) [W] |
– |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 GcIP20, Ta (see X20 user's manual)FTZÚ 09 ATEX 0083X |
| UL |
cULus E115267Industrial control equipment |
| HazLoc |
cCSAus 244665Process control equipmentfor hazardous locations Class I, Division 2, Groups ABCD, T5 |
| KC |
Yes |
| Input voltage |
24 VDC -15% / +20% |
| Fuse |
Required line fuse: Max. 10 A, slow-blow |
| Reverse polarity protection |
No |
| Nominal output voltage |
24 VDC |
| Behavior on short circuit |
Required line fuse |
| Permissible contact load |
10 A |
| Horizontal |
Yes |
| Vertical |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Horizontal mounting orientation |
-25 to 60°C |
| Vertical mounting orientation |
-25 to 50°C |
| Derating |
– |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
5 to 95%, non-condensing |
| Note |
Order 1x terminal block X20TB06 or X20TB12 separately. Order 1x bus module X20BM11 or X20BM15 separately. |
| Pitch |
12.5+0.2 mm |