Fieldbus: CANopenAuto-configuration of I/O modulesI/O configuration via the fieldbusConstant response times even with large amounts of data (max. 32 Rx and 32 Tx PDOs)Configurable I/O cycle (0.5 to 4…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Fieldbus: CANopenAuto-configuration of I/O modulesI/O configuration via the fieldbusConstant response times even with large amounts of data (max. 32 Rx and 32 Tx PDOs)Configurable I/O cycle (0.5 to 4 ms)Possible to configure the transfer rate or have it detected automaticallyHeartbeat consumer and producerEmergency producer2x SDO server, NMT slaveSimple bootup (autostart)Terminal access via the serial interface on the X20PS9400
Controller Area Network (CAN) is widespread in automation technology. CAN topology is based on a line structure and uses twisted wire pairs for data transfer. CANopen is a higher-layer protocol based on CAN. The standardized protocol offers very flexible configuration options.This bus controller makes it possible to connect up to 253 X2X Link I/O modules to CANopen. A transition between IP20 and IP67 protection is possible by directly connecting X20, X67 or XV modules to one another at distances of up to 100 m each across control cabinet boundaries as required. All CANopen operating modes such as synchronous, event and polling are supported as well as PDO linking, life/node guarding, heartbeat, emergency objects and much more. With multifunction modules, the bus controller supports only the default function model in the event of automatic configuration by the bus controller (see the respective module description). Automation Studio V4.3 or later can be used to easily create configuration files (e.g. DCF files). All other function models are also supported by transferring configuration data to the bus controller (e.g. via the master environment with an SDO download). Automation Studio can be downloaded at no cost from the B&R website (www.br-automation.com). The evaluation license is permitted to be used to create complete configurations for fieldbus bus controllers at no cost.
Specification
| Bus controller |
CANopen slave |
|---|---|
| B&R ID code |
0xAD3E |
| Status indicators |
Module status, bus function, data transfer |
| Module status |
Yes, using LED status indicator and software |
| Bus function |
Yes, using LED status indicator and software |
| Data transfer |
Yes, using LED status indicator |
| Bus |
2 W |
| Additional power dissipation caused by actuators (resistive) [W] |
– |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc |
| UL |
cULus E115267 |
| HazLoc |
cCSAus 244665 |
| DNV |
Temperature: B (0 to 55°C) |
| CCS |
Yes |
| LR |
ENV1 |
| KR |
Yes |
| ABS |
Yes |
| BV |
EC33B |
| Fieldbus |
No limitation |
| Variant |
9-pin male DSUB connector |
| Max. distance |
1000 m |
| Transfer rate |
Max. 1 Mbit/s |
| Default transfer rate |
Automatic transfer rate detection or fixed setting |
| X2X Link |
500 μs |
| Synchronization between bus systems possible |
No |
| Electrical isolation |
CANopen isolated from I/O |
| Horizontal |
Yes |
| Vertical |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Horizontal mounting orientation |
-25 to 60°C |
| Vertical mounting orientation |
-25 to 50°C |
| Derating |
– |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
5 to 95%, non-condensing |
| Note |
Order 1x terminal block X20TB12 separately. |
| Pitch |