B&R X20BC00E3
Fieldbus: PROFINET IOI/O configuration via the fieldbusConformance Class B (RT)Minimum cycle time 1 msIntegrated switch for cabling multiple slaves100 Mbit/s full duplex modeUp to 1440 bytes of input…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Fieldbus: PROFINET IOI/O configuration via the fieldbusConformance Class B (RT)Minimum cycle time 1 msIntegrated switch for cabling multiple slaves100 Mbit/s full duplex modeUp to 1440 bytes of input data and up to 1440 bytes of output data are possibleIntegrated websitePROFINET diagnostics and module diagnostics during runtime from within the master environmentModule and switch diagnostics during runtime using the website or SNMP
PROFINET (Process Field Network) is an Industrial Ethernet protocol. It uses TCP/IP and is real-time capable. X20 modules or other modules that are based on X2X Link can be connected to the bus controller. Modular system configurations are optimally supported by PROFINET IO. Using the device description file (GSDML format), it is very easy to handle project configuration in the respective engineering tool from the manufacturer of the master device.
Specification
| Bus controller |
PROFINET IO slave |
|---|---|
| B&R ID code |
0xBB7D |
| Status indicators |
Module status, bus function |
| Module status |
Yes, using LED status indicator and software |
| Bus function |
Yes, using LED status indicator and software |
| Bus |
2.5 W |
| Additional power dissipation caused by actuators (resistive) [W] |
– |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc |
| UL |
cULus E115267 |
| HazLoc |
cCSAus 244665 |
| Fieldbus |
1 ms |
| Conformance class |
B |
| Performance class |
RT |
| Variant |
2x shielded RJ45 (switch) |
| Line length |
Max. 100 m between 2 stations (segment length) |
| Transfer rate |
100 Mbit/s |
| Physical layer |
100BASE-TX |
| Half-duplex |
Yes |
| Full-duplex |
Yes |
| Autonegotiation |
Yes |
| Auto-MDI/MDIX |
Yes |
| X2X Link |
250 μs |
| Synchronization between bus systems possible |
Yes |
| Electrical isolation |
PROFINET isolated from bus and I/O |
| Horizontal |
Yes |
| Vertical |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Horizontal mounting orientation |
-25 to 60°C |
| Vertical mounting orientation |
-25 to 50°C |
| Derating |
– |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
5 to 95%, non-condensing |
| Note |
Order 1x terminal block X20TB12 separately. |
| Pitch |
37.5+0.2 mm |