Fast delivery within 72 Hours
B&R X20BC0073
Fieldbus: CAN busAutomatic firmware update via the fieldbusIntegrated I/O access in B&R Automation StudioIntegrated terminating resistor
The bus controller…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Fieldbus: CAN busAutomatic firmware update via the fieldbusIntegrated I/O access in B&R Automation StudioIntegrated terminating resistor
The bus controller makes it possible to connect X2X Link I/O nodes to CAN I/O. CAN I/O is a transfer protocol based on standard CAN bus that is fully integrated in the B&R system.Up to 43 logic I/O modules can be connected to the bus controller. Up to 16 of them can be analog modules.With multifunction modules, the bus controller supports only the default function model in the event of automatic configuration by the bus controller (see the respective module description).
Specification
| Bus controller |
CAN I/O slave |
|---|---|
| B&R ID code |
0x1F1D |
| Status indicators |
Module status, bus function, data transfer, terminating resistor |
| Module status |
Yes, using LED status indicator and software |
| Bus function |
Yes, using LED status indicator |
| Data transfer |
Yes, using LED status indicator |
| Terminating resistor |
Integrated in module |
| Bus |
1.5 W |
| Additional power dissipation caused by actuators (resistive) [W] |
– |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc |
| UL |
cULus E115267 |
| HazLoc |
cCSAus 244665 |
| KC |
Yes |
| Fieldbus |
CAN I/O slave |
| Variant |
5-pin male multipoint connector |
| Max. distance |
1000 m |
| Transfer rate |
Max. 1 Mbit/s |
| Default transfer rate |
Automatic transfer rate detection or fixed setting |
| X2X Link cycle time |
Permanently set to 1 ms |
| Synchronization between bus systems possible |
No |
| Electrical isolation |
CAN I/O isolated from I/O |
| Horizontal |
Yes |
| Vertical |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Horizontal mounting orientation |
-25 to 60°C |
| Vertical mounting orientation |
-25 to 50°C |
| Derating |
– |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
5 to 95%, non-condensing |
| Note |
Order 1x terminal block TB2105 separately. |
| Pitch |
37.5+0.2 mm |

Reviews