Fast delivery within 72 Hours
B&R X20BC0063
Fieldbus: PROFIBUS DPI/O configuration via the fieldbusExtensive device, module, and channel diagnosis according to PROFIBUS DP standardCommunication with X2X Link I/O nodes even works when some nodes…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Fieldbus: PROFIBUS DPI/O configuration via the fieldbusExtensive device, module, and channel diagnosis according to PROFIBUS DP standardCommunication with X2X Link I/O nodes even works when some nodes are missing or without power
PROFIBUS DP is based on the physics of the RS485 interface. Data transfer is controlled using a hybrid bus access procedure: Active stations receive communication rights via a token passing procedure and can then access all stations on the network according to the master-slave principle. The maximum time of circulation for a token can be configured, which results in a defined cycle time.Access represents various services for the user for both cyclic and for acyclic data transfer.This bus controller makes it possible to connect X2X Link I/O nodes to PROFIBUS DP. It supports PROFIBUS DP with all of its options and other additional properties. In addition to the device, module and channel diagnostics provided in the PROFIBUS standard, it is also possible, for example, to switch to the slot diagnostics option in S7 format. X20 or other modules based on X2X Link can be connected to the bus controller. The configuration of the modular system is optimally supported by PROFIBUS DP.With multifunction modules, the bus controller supports only the default function model in the event of automatic configuration by the bus controller (see the respective module description).
Specification
| Bus controller |
PROFIBUS DP V0 slave |
|---|---|
| B&R ID code |
0x1F1C |
| Status indicators |
Module status, bus function, data transfer |
| Module status |
Yes, using LED status indicator and software |
| Bus function |
Yes, using LED status indicator |
| Data transfer |
Yes, using LED status indicator |
| Bus |
2.3 W |
| Additional power dissipation caused by actuators (resistive) [W] |
– |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc |
| UL |
cULus E115267 |
| HazLoc |
cCSAus 244665 |
| KC |
Yes |
| Fieldbus |
No limitation |
| Variant |
9-pin female DSUB connector |
| Max. distance |
1200 m |
| Transfer rate |
Max. 12 Mbit/s |
| Default transfer rate |
Automatic transfer rate detection |
| X2X Link |
400 μs |
| Synchronization between bus systems possible |
No |
| Electrical isolation |
PROFIBUS isolated from I/O |
| Horizontal |
Yes |
| Vertical |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Horizontal mounting orientation |
-25 to 60°C |
| Vertical mounting orientation |
-25 to 50°C |
| Derating |
– |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
5 to 95%, non-condensing |
| Note |
Order 1x terminal block X20TB12 separately. |
| Pitch |
37.5+0.2 mm |

Reviews