B&R X20BC0063

Fieldbus: PROFIBUS DPI/O configuration via the fieldbusExtensive device, module, and channel diagnosis according to PROFIBUS DP standardCommunication with X2X Link I/O nodes even works when some nodes…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

Fieldbus: PROFIBUS DPI/O configuration via the fieldbusExtensive device, module, and channel diagnosis according to PROFIBUS DP standardCommunication with X2X Link I/O nodes even works when some nodes are missing or without power

PROFIBUS DP is based on the physics of the RS485 interface. Data transfer is controlled using a hybrid bus access procedure: Active stations receive communication rights via a token passing procedure and can then access all stations on the network according to the master-slave principle. The maximum time of circulation for a token can be configured, which results in a defined cycle time.Access represents various services for the user for both cyclic and for acyclic data transfer.This bus controller makes it possible to connect X2X Link I/O nodes to PROFIBUS DP. It supports PROFIBUS DP with all of its options and other additional properties. In addition to the device, module and channel diagnostics provided in the PROFIBUS standard, it is also possible, for example, to switch to the slot diagnostics option in S7 format. X20 or other modules based on X2X Link can be connected to the bus controller. The configuration of the modular system is optimally supported by PROFIBUS DP.With multifunction modules, the bus controller supports only the default function model in the event of automatic configuration by the bus controller (see the respective module description).

Specification

Bus controller

PROFIBUS DP V0 slave

B&R ID code

0x1F1C

Status indicators

Module status, bus function, data transfer

Module status

Yes, using LED status indicator and software

Bus function

Yes, using LED status indicator

Data transfer

Yes, using LED status indicator

Bus

2.3 W

Additional power dissipation caused by actuators (resistive) [W]

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

KC

Yes

Fieldbus

No limitation

Variant

9-pin female DSUB connector

Max. distance

1200 m

Transfer rate

Max. 12 Mbit/s

Default transfer rate

Automatic transfer rate detection

Synchronization between bus systems possible

No

Electrical isolation

PROFIBUS isolated from I/O
PROFIBUS not isolated from bus

Horizontal

Yes

Vertical

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

-25 to 60°C

Vertical mounting orientation

-25 to 50°C

Derating

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

5 to 95%, non-condensing

Note

Order 1x terminal block X20TB12 separately.
Order 1x power supply module X20PS9400 or X20PS9402 separately.
Order 1x bus base X20BB80 separately.

Pitch