Fast delivery within 72 Hours

B&R X20BC0063

Fieldbus: PROFIBUS DPI/O configuration via the fieldbusExtensive device, module, and channel diagnosis according to PROFIBUS DP standardCommunication with X2X Link I/O nodes even works when some nodes…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Fieldbus: PROFIBUS DPI/O configuration via the fieldbusExtensive device, module, and channel diagnosis according to PROFIBUS DP standardCommunication with X2X Link I/O nodes even works when some nodes are missing or without power

PROFIBUS DP is based on the physics of the RS485 interface. Data transfer is controlled using a hybrid bus access procedure: Active stations receive communication rights via a token passing procedure and can then access all stations on the network according to the master-slave principle. The maximum time of circulation for a token can be configured, which results in a defined cycle time.Access represents various services for the user for both cyclic and for acyclic data transfer.This bus controller makes it possible to connect X2X Link I/O nodes to PROFIBUS DP. It supports PROFIBUS DP with all of its options and other additional properties. In addition to the device, module and channel diagnostics provided in the PROFIBUS standard, it is also possible, for example, to switch to the slot diagnostics option in S7 format. X20 or other modules based on X2X Link can be connected to the bus controller. The configuration of the modular system is optimally supported by PROFIBUS DP.With multifunction modules, the bus controller supports only the default function model in the event of automatic configuration by the bus controller (see the respective module description).

Specification

Bus controllerPROFIBUS DP V0 slave
B&R ID code0x1F1C
Status indicatorsModule status, bus function, data transfer
Module statusYes, using LED status indicator and software
Bus functionYes, using LED status indicator
Data transferYes, using LED status indicator
Bus2.3 W
Additional power dissipation caused by actuators (resistive) [W]
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
KCYes
FieldbusNo limitation
Variant9-pin female DSUB connector
Max. distance1200 m
Transfer rateMax. 12 Mbit/s
Default transfer rateAutomatic transfer rate detection
Synchronization between bus systems possibleNo
Electrical isolationPROFIBUS isolated from I/O PROFIBUS not isolated from bus
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
Derating
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing
NoteOrder 1x terminal block X20TB12 separately. Order 1x power supply module X20PS9400 or X20PS9402 separately. Order 1x bus base X20BB80 separately.
Pitch37.5+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20BC0063”

Your email address will not be published. Required fields are marked *