Fast delivery within 72 Hours

B&R X20AO2632

 422,94

3 in stock

2 analog outputsEither current or voltage signal possible16-bit digital converter resolutionNetTime timestamp: Switch-off time

The module is equipped with…

3 in stock

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

2 analog outputsEither current or voltage signal possible16-bit digital converter resolutionNetTime timestamp: Switch-off time

The module is equipped with 2 outputs with 16-bit (including sign) digital converter resolution. It is possible to select between the current and voltage signal using different terminals. This module is designed for X20 6-pin terminal blocks. If needed (e.g. for logistical reasons), the 12-pin terminal block can also be used.NetTime timestamp for outputFor many applications, not only the output value is important, but also the exact switching time. The module is equipped with a NetTime timestamp function for this that can define a switching time to the nearest microsecond.The timestamp function is based on synchronized timers. The CPU can predefine output events and provide them with a timestamp. After transferring the respective data, including the exact time, the module executes the predefined action at the exactly defined time.

Specification

I/O module2 analog outputs ±10 V or 0 to 20 mA
B&R ID code0x1BA4
Status indicatorsI/O function per channel, operating state, module status
Module run/errorYes, using LED status indicator and software
Channel typeYes, using software
Bus0.01 W
Internal I/O1.1 W
Additional power dissipation caused by actuators (resistive) [W]
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
CCSYes
LRENV1
KRYes
ABSYes
BVEC33B Temperature: 5 – 55°C Vibration: 4 g EMC: Bridge and open deck
KCYes
Output±10 V or 0 to 20 mA, via different terminal connections
VoltageMax. 0.11%, from 10 MΩ → 1 kΩ, resistive
CurrentMax. 0.5%, from 1 Ω → 600 Ω, resistive
Conversion time50 µs for all outputs
Settling time on output change over entire range500 μs (Rev. <H0: 1 ms)
Switch on/off behaviorInternal enable relay for startup
Gain±0.09%
Offset±0.045%
Output protectionShort-circuit proof
Short-circuit proofCurrent limiting ±40 mA
Output filterFirst-order low-pass filter / cutoff frequency 10 kHz
Nonlinearity<0.007%
Insulation voltage between channel and bus500 Veff
Electrical isolationChannel isolated from bus Channel not isolated from channel
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
Derating
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing
NoteOrder 1x terminal block X20TB06 or X20TB12 separately. Order 1x bus module X20BM11 separately.
Pitch12.5+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20AO2632”

Your email address will not be published. Required fields are marked *