Fast delivery within 72 Hours
B&R 8I86T405500.00-000
Base device for ACOPOSinverter P86, 3x 380 to 480 V, 55 kW, EMC filter and brake chopper.Order number – ACOPOSinverter P86:8I86T405500.0P-200: Inverter with POWERLINK communication card
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Base device for ACOPOSinverter P86, 3x 380 to 480 V, 55 kW, EMC filter and brake chopper.Order number – ACOPOSinverter P86:8I86T405500.0P-200: Inverter with POWERLINK communication card
Specification
| CE |
Yes |
|---|---|
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| UL |
cULus E225616 |
| Specified on nameplate |
55 kW (75 HP) |
| Mains input voltage |
3x 380 VAC -15% to 480 VAC +10% |
| Frequency |
50 to 60 Hz ±5% |
| Apparent power (at 480 VAC) |
72.2 kVA |
| Max. assumed short-circuit current (Isc) (short-circuit current at connection point) |
50 kA |
| Inrush current |
Max. 187 A |
| At 380 VAC |
98.9 A |
| At 480 VAC |
86.9 A |
| External cooling |
987 W |
| Natural cooling |
156 W |
| Integrated EMC filter |
Yes |
| Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network) |
C2 level at 4 kHz with 150 m cable |
| Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system) |
C3 level at 4 kHz with 300 m cable |
| With add-on filter |
8I0FT200.200-1 |
| Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network) |
– |
| Nominal output current |
106 A |
| At nominal clock frequency (4 kHz or 2.5 kHz with higher inverter power) |
No derating |
| Other clock frequencies |
The derating curves are included in the installation instructions, which can be downloaded from http://www.br-automation.com. |
| Starting at 1000 m above sea level |
1%, per 100 m |
| Max. transient current for 60 s |
159 A |
| Output frequency range |
0.1 to 500 Hz |
| Nominal clock frequency |
2.5 kHz |
| Min. |
2 kHz |
| Max. |
8 kHz |
| Shielded cable |
150 m |
| Non-shielded cable |
300 m |
| Induction motor |
Sensorless vector control: |
| Synchronous motor |
Sensorless vector control: |
| Main protective functions of inverter |
Thermal protection against power stage overheating |
| Integrated dynamic brake transistors |
Yes |
| Min. resistance value (external) |
2.5 Ω |
| Input voltage |
24 VDC (min. 20.4 VDC, max. 27 VDC) |
| Current |
500 Ω |
| Output voltage 24 VDC |
24 VDC (min. 20.4 VDC, max. 27 VDC) |
| Max. output current at 24 VDC |
Max. 200 mA |
| Output voltage 10 VDC |
10.5 VDC ±5% |
| Max. output current at 10 VDC |
Max. 10 mA |
| Type |
Type 3 |
| Quantity |
2 |
| Nominal voltage |
30 VDC / 250 VAC |
| Input circuit |
Source |
| Low |
<0.6 V |
| High |
>2.5 V |
| Input - ACOPOSinverter |
Yes |
| Input - Input |
No |
| Sampling time |
5 ms ±1 ms |
| Input impedance |
2.2 kΩ |
| Input frequency |
0 to 30 kHz |
| Nonlinearity |
±0.2% |
| Basic accuracy |
±1% with temperature fluctuation of 60°C |
| Voltage |
470 Ω |
| Resolution |
10-bit |
| Max. voltage |
30 VDC |
| Output circuit |
Source or sink |
| Max. current |
100 mA |
| Switching current range |
Min. switching current: 5 mA at 24 VDC |
| Relay 1 |
1 changeover contact |
| Relay 2 |
1 normally open contact |
| Relay 3 |
1 normally open contact |
| Output - ACOPOSinverter |
Yes |
| Output - Output |
No |
| Response time (max.) |
5 ms ±0.5 ms |
| Output |
0 to 10 VDC or 0 to 20 mA |
| Power dissipation relative to continuous apparent power |
IE2 (10, 25): 0.5% (3x 380 VAC), 0.4% (3x 480 VAC) |
| Nominal losses in standby mode |
32 W |
| Degree of protection per EN 61800-5-1 |
IP20 |
| Degree of protection per EN 60529 |
IP20 |
| Relative humidity per IEC 60068-2-3 |
5 to 95%, non-condensing |
| Maximum installation elevation |
≤1000 m without derating |
| Max. pollution degree per IEC/EN 61800-5-1 |
2 (non-conductive pollution) |
| Ambient conditions per IEC 60721-3-3 |
Class 3C3 and 3S3 |
| Operating position |
Vertical mounting orientation ±10° |
| Operation |
-15 to 50°C without derating |
| Storage |
-40 to 70°C |
| Max. vibration resistance |
1 gn 13 to 200 Hz EN/IEC 60068-2-6 |
| Max. shock resistance |
15 gn (duration = 11 ms) per EN/IEC 60721-3-3 class 3M3 |
| Width |
271 mm |
| Height |
908 mm |
| Depth |
309 mm |
| Weight |
57.9 kg |

Reviews
Clear filtersThere are no reviews yet.