Fast delivery within 72 Hours

B&R 8I86T404500.00-000

Base device for ACOPOSinverter P86, 3x 380 to 480 V, 45 kW, EMC filter and brake chopper.Order number – ACOPOSinverter P86:8I86T404500.0P-200: Inverter with POWERLINK communication card

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

Base device for ACOPOSinverter P86, 3x 380 to 480 V, 45 kW, EMC filter and brake chopper.Order number – ACOPOSinverter P86:8I86T404500.0P-200: Inverter with POWERLINK communication card

Specification

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

UL

cULus E225616Power conversion equipment

Specified on nameplate

45 kW (60 HP)

Mains input voltage

3x 380 VAC -15% to 480 VAC +10%

Frequency

50 to 60 Hz ±5%

Apparent power (at 480 VAC)

59.7 kVA

Max. assumed short-circuit current (Isc)(short-circuit current at connection point)

50 kA

Inrush current

Max. 176 A

At 380 VAC

81.4 A

At 480 VAC

71.8 A

External cooling

776 W

Natural cooling

143 W

Integrated EMC filter

Yes

Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network)

C2 level at 4 kHz with 150 m cable

Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system)

C3 level at 4 kHz with 300 m cable

With add-on filter

8I0FT160.200-1

Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network)

Nominal output current

88 A

At nominal clock frequency (4 kHz or 2.5 kHz with higher inverter power)

No derating

Other clock frequencies

The derating curves are included in the installation instructions, which can be downloaded from http://www.br-automation.com.

Starting at 1000 m above sea level

1%, per 100 m

Max. transient current for 60 s

132 A

Max. transient current for 2 s

132 A

Output frequency range

0.1 to 500 Hz

Nominal clock frequency

2.5 kHz

Min.

2 kHz

Max.

8 kHz

Shielded cable

150 m

Non-shielded cable

300 m

Induction motor

Sensorless vector control:1. Voltage controlled with constant torque→ Default mode2. Voltage controlled with variable torque→ Energy-saving mode, e.g. for fans and pumpsVector control with encoder:1. Current-controlled with constant torque→ Default modeSensorless slip control:1. With V/f characteristic curve for constant torque→ Default mode2. With V/f characteristic curve for constant torque (up to 6 f ranges)→ Mode for individual special applications3. With V/f characteristic curve for quadratically increasing torque→ Energy-saving mode, e.g. for fans and pumps

Synchronous motor

Sensorless vector control:1. Voltage controlled with constant torque→ Default modeVector control with encoder:1. Current-controlled with constant torque→ Default mode

Main protective functions of inverter

Thermal protection against power stage overheatingProtection against short circuits between motor phases, overcurrent between output phases and ground, overvoltages on the DC bus, exceeding the speed limit. Safety function for: Overvoltage and undervoltage of the mains supply, mains phase failure with 3-phase power supply

Integrated dynamic brake transistors

Yes

Min. resistance value (external)

2.5 Ω

Input voltage

24 VDC (min. 20.4 VDC, max. 27 VDC)

Current

500 Ω

Output voltage 24 VDC

24 VDC (min. 20.4 VDC, max. 27 VDC)

Max. output current at 24 VDC

Max. 200 mA

Output voltage 10 VDC

10.5 VDC ±5%

Max. output current at 10 VDC

Max. 10 mA

Type

Type 3

Quantity

2

Nominal voltage

30 VDC / 250 VAC

Input circuit

Source

Low

<0.6 V

High

>2.5 V

Input - ACOPOSinverter

Yes

Input - Input

No

Sampling time

5 ms ±1 ms

Input impedance

2.2 kΩ

Input frequency

0 to 30 kHz

Nonlinearity

±0.2%

Basic accuracy

±1% with temperature fluctuation of 60°C

Voltage

470 Ω

Resolution

10-bit

Max. voltage

30 VDC

Output circuit

Source or sink

Max. current

100 mA

Switching current range

Min. switching current: 5 mA at 24 VDCMax. switching current:R1: At cos φ = 1: Max. 3 A / At cos φ = 0.4: Max. 2 AR2 and R3: At cos φ = 1: Max. 5 A / At cos φ = 0.4: Max. 2 A

Relay 1

1 changeover contact

Relay 2

1 normally open contact

Relay 3

1 normally open contact

Output - ACOPOSinverter

Yes

Output - Output

No

Response time (max.)

5 ms ±0.5 ms

Output

0 to 10 VDC or 0 to 20 mA

Power dissipation relative to continuous apparent power

IE2 (10, 25): 0.5% (3x 380 VAC), 0.4% (3x 480 VAC)IE2 (50, 25): 0.5% (3x 380 VAC), 0.4% (3x 480 VAC)IE2 (10, 50): 0.7% (3x 380 VAC), 0.6% (3x 480 VAC)IE2 (50, 50): 0.7% (3x 380 VAC), 0.6% (3x 480 VAC)IE2 (90, 50): 0.8% (3x 380 VAC), 0.6% (3x 480 VAC)IE2 (10, 100): 1.3% (3x 380 VAC), 1.1% (3x 480 VAC)IE2 (50, 100): 1.3% (3x 380 VAC), 1% (3x 480 VAC)IE2 (90, 100): 1.5% (3x 380 VAC), 1.2% (3x 480 VAC)

Nominal losses in standby mode

32 W

Degree of protection per EN 61800-5-1

IP20

Degree of protection per EN 60529

IP20

Relative humidity per IEC 60068-2-3

5 to 95%, non-condensing

Maximum installation elevation

≤1000 m without derating1000 to 4800 m with Derating

Max. pollution degree per IEC/EN 61800-5-1

2 (non-conductive pollution)

Ambient conditions per IEC 60721-3-3

Class 3C3 and 3S3

Operating position

Vertical mounting orientation ±10°

Operation

-15 to 50°C without derating50 to 60°C with derating

Storage

-40 to 70°C

Max. vibration resistance

1 gn 13 to 200 Hz EN/IEC 60068-2-6 1.5 mm peak to peak 2 to 13 Hz EN/IEC 60068-2-6

Max. shock resistance

15 gn (duration = 11 ms) per EN/IEC 60721-3-3 class 3M3

Width

271 mm

Height

908 mm

Depth

309 mm

Weight

56.4 kg

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R 8I86T404500.00-000”

Your email address will not be published. Required fields are marked *