B&R 8I84T403700.01P-1
ACOPOSinverter P84, 3x 380 to 480 V, 37 kW, integrated EMC filter and brake chopper, shield plate included in delivery, POWERLINK interface.
Shipping & Delivery
- 
Courier delivery
 
Our courier will deliver to the specified address
2-3 Days
From $20
- 
DHL Courier delivery
 
DHL courier will deliver to the specified address
2-3 Days
From $40
- 
Warranty 1 year
 
- 
Free 30-Day returns
 
Description
ACOPOSinverter P84, 3x 380 to 480 V, 37 kW, integrated EMC filter and brake chopper, shield plate included in delivery, POWERLINK interface.
Specification
| CE | 
 Yes  | 
|---|---|
| UL | 
 cULus E225616  | 
| KC | 
 Yes  | 
| Specified on nameplate | 
 37 kW  | 
| Mains input voltage | 
 3x 380 VAC -15% to 480 VAC +10%  | 
| Frequency | 
 50 to 60 Hz ±5%  | 
| Apparent power (at 380 VAC) | 
 55.3 kVA  | 
| Max. assumed short-circuit current (Isc) (short-circuit current at connection point) | 
 22 kA  | 
| At 400 VAC | 
 67.3 A  | 
| At 380 VAC | 
 79 A  | 
| At 480 VAC | 
 69 A  | 
| Power dissipation at nominal load and nominal clock frequency | 
 861 W  | 
| Integrated EMC filter | 
 Yes  | 
| Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network) | 
 ≤100 m  | 
| Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network) | 
 ≤300 m / ≤200 m  | 
| Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system) | 
 ≤300 m / ≤200 m  | 
| With add-on filter | 
 8I0FT092.300-1  | 
| At nominal clock frequency (4 kHz or 2.5 kHz with higher inverter power) | 
 No derating (up to 50°C)  | 
| Other clock frequencies | 
 The derating curves are included in the installation instructions, which can be downloaded from the website (www.br-automation.com).  | 
| Starting at 1000 m above sea level | 
 1%, per 100 m  | 
| At 460 VAC | 
 65 A  | 
| Max. transient current for 60 s | 
 118.5 A  | 
| Max. transient current for 2 s | 
 130 A  | 
| Output frequency range | 
 0.5 to 599 Hz  | 
| Nominal clock frequency | 
 2.5 kHz  | 
| Min. | 
 3 mA for 24 VDC  | 
| Max. | 
 16 kHz  | 
| Short-term overload torque (typical value) | 
 170% of the motor's rated torque (typical value at ±10%) for 60 s  | 
| With braking resistor | 
 Up to 150% of the rated motor torque  | 
| Without braking resistor (typical value) | 
 30% of the rated motor torque  | 
| Shielded cable | 
 100 m  | 
| Non-shielded cable | 
 150 m  | 
| Induction motor | 
 Flux vector control (FVC) with encoder (voltage vector) (current vector)  | 
| Main protective functions of inverter | 
 Thermal protection against the power stage overheating  | 
| Motor protection | 
 Thermal protection integrated in the inverter through continually calculating the l²t value while taking the speed into consideration:  | 
| Integrated dynamic brake transistors | 
 Yes  | 
| Operating ratio for dynamic brake transistors | 
 The dynamic brake transistor is designed to tolerate the following values:  | 
| Min. resistance value (external) | 
 6.7 Ω  | 
| Input voltage | 
 24 VDC (min. 19 V, max. 30 V)  | 
| Power consumption | 
 30 W  | 
| Output voltage 24 VDC | 
 24 VDC (min. 21 V, max. 27 V)  | 
| Max. output current at 24 VDC | 
 200 mA  | 
| Output voltage 10.5 VDC | 
 10.5 VDC ±5%  | 
| Max. output current 10.5 VDC | 
 10 mA  | 
| Low | 
 <5 V  | 
| High | 
 >15 V  | 
| Input - ACOPOSinverter | 
 Yes  | 
| Input - Input | 
 No  | 
| Quantity | 
 1  | 
| Nominal voltage | 
 30 VDC / 250 VAC  | 
| Response time | 
 ≤100 ms  | 
| Input impedance | 
 3.5 kΩ  | 
| Input circuit | 
 Source or sink  | 
| Type | 
 Type 3  | 
| Sampling time | 
 <2 ms ±0.5 ms  | 
| Voltage | 
 470 Ω  | 
| Voltage/Current | 
 0 to 10 V or 0 to 20 mA  | 
| Resolution | 
 10-bit  | 
| Current | 
 500 Ω  | 
| Switching capacity | 
 Max. 2 A at 250 VAC or 30 VDC with resistive load  | 
| With resistive load (cos φ = 1 and L/R = 0 ms) | 
 2 A for 250 VAC or 30 VDC  | 
| With inductive load (cos φ = 0.4 and L/R = 7 ms) | 
 1.5 A for 250 VAC or 30 VDC  | 
| Relay 1 | 
 1 N.O. contact and 1 N.C. contact with a common point  | 
| Relay 2 | 
 1 N.O. contact  | 
| Response time (max.) | 
 <7 ms ±0.5 ms  | 
| Output - ACOPOSinverter | 
 Yes  | 
| Output - Output | 
 No  | 
| Output | 
 0 to 10 V or 0 to 20 mA  | 
| Update time | 
 <2 ms ±0.5 ms  | 
| Installation elevation above sea level | 
 0 to 1000 m  | 
| Degree of protection per EN 60529 | 
 Upper part: IP21 and IP41  | 
| Ambient temperature | 
 -10 to 50°C  | 
| Max. ambient temperature | 
 Up to 60°C  | 
| Relative humidity per IEC 60068-2-3 | 
 5 to 95%, non-condensing  | 
| Maximum installation elevation | 
 Up to 3000 m  | 
| Max. pollution degree per IEC/EN 61800-5-1 | 
 2 (non-conductive pollution)  | 
| Ambient conditions per IEC 60721-3-3 | 
 Class 3C1 and 3S2  | 
| Operating position | 
 Vertical installation ±10%  | 
| Storage | 
 -25 to 70°C  | 
| Operation | 
 15 g, 11 ms  | 
| Width | 
 240 mm  | 
| Height | 
 550 mm  | 
| Depth | 
 266 mm  | 
| Weight | 
 37 kg  | 
	
	
				
				
		
		
		
		
		
		
		