B&R 8I84T403000.01P-1
ACOPOSinverter P84, 3x 380 to 480 V, 30 kW, integrated EMC filter and brake chopper, shield plate included in delivery, POWERLINK interface.
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
ACOPOSinverter P84, 3x 380 to 480 V, 30 kW, integrated EMC filter and brake chopper, shield plate included in delivery, POWERLINK interface.
Specification
| CE |
Yes |
|---|---|
| UL |
cULus E225616Power conversion equipment |
| KC |
Yes |
| Specified on nameplate |
30 kW40 PS |
| Mains input voltage |
3x 380 VAC -15% to 480 VAC +10% |
| Frequency |
50 to 60 Hz ±5% |
| Apparent power (at 380 VAC) |
43.4 kVA |
| Max. assumed short-circuit current (Isc)(short-circuit current at connection point) |
22 kA |
| At 400 VAC |
54.5 A |
| At 380 VAC |
66 A |
| At 480 VAC |
56 A |
| Power dissipation at nominal load and nominal clock frequency |
799 W |
| Integrated EMC filter |
Yes |
| Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network) |
≤100 m |
| Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network) |
≤300 m / ≤200 m |
| Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system) |
≤300 m / ≤200 m |
| With add-on filter |
8I0FT092.300-1 |
| At nominal clock frequency (4 kHz or 2.5 kHz with higher inverter power) |
No derating (up to 50°C) |
| Other clock frequencies |
The derating curves are included in the installation instructions, which can be downloaded from the website (www.br-automation.com). |
| Starting at 1000 m above sea level |
1%, per 100 m |
| At 460 VAC |
56 A |
| Max. transient current for 60 s |
99 A |
| Max. transient current for 2 s |
109 A |
| Output frequency range |
0.5 to 599 Hz |
| Nominal clock frequency |
4 kHz |
| Min. |
3 mA for 24 VDC |
| Max. |
16 kHz |
| Short-term overload torque (typical value) |
170% of the motor's rated torque (typical value at ±10%) for 60 s220% of the motor's rated torque (typical value at ±10%) for 2 s |
| With braking resistor |
Up to 150% of the rated motor torque |
| Without braking resistor (typical value) |
30% of the rated motor torque |
| Shielded cable |
100 m |
| Non-shielded cable |
150 m |
| Induction motor |
Flux vector control (FVC) with encoder (voltage vector) (current vector)Flux vector control (SFVC) without encoder (voltage or current vector)Voltage/frequency ratio – V/f characteristic curve (2 or 5 points)ENA energy adjustment system for asymmetrical loads |
| Main protective functions of inverter |
Thermal protection against the power stage overheatingProtection against: Short circuits between motor phases, mains phase failure, overcurrent between output phases and ground, overvoltages on the DC bus, interruptions in the control loop, exceeding the limit for rotary speed. Safety function for: Overvoltage and undervoltage on the mains supply, mains phase failure on a 3-phase supply |
| Motor protection |
Thermal protection integrated in the inverter through continually calculating the l²t value while taking the speed into consideration: -The thermal state of the motor is stored when the frequency inverter is switched off. -The functionality can be adjusted according to the motor type (externally cooled or self-cooling) using an operator interface. Protection against motor phase failuresProtection provided by PTC sensors |
| Integrated dynamic brake transistors |
Yes |
| Operating ratio for dynamic brake transistors |
The dynamic brake transistor is designed to tolerate the following values: -Rated motor power continuously-150% of the rated motor power for 60 s |
| Min. resistance value (external) |
13.3 Ω |
| Input voltage |
24 VDC (min. 19 V, max. 30 V) |
| Power consumption |
30 W |
| Output voltage 24 VDC |
24 VDC (min. 21 V, max. 27 V) |
| Max. output current at 24 VDC |
200 mA |
| Output voltage 10.5 VDC |
10.5 VDC ±5% |
| Max. output current 10.5 VDC |
10 mA |
| Low |
<5 V |
| High |
>15 V |
| Input - ACOPOSinverter |
Yes |
| Input - Input |
No |
| Quantity |
1 |
| Nominal voltage |
30 VDC / 250 VAC |
| Response time |
≤100 ms |
| Input impedance |
3.5 kΩ |
| Input circuit |
Source or sink |
| Type |
Type 3 |
| Sampling time |
<2 ms ±0.5 ms |
| Voltage |
470 Ω |
| Voltage/Current |
0 to 10 V or 0 to 20 mA |
| Resolution |
10-bit |
| Current |
500 Ω |
| Switching capacity |
Max. 2 A at 250 VAC or 30 VDC with resistive load |
| With resistive load (cos φ = 1 and L/R = 0 ms) |
2 A for 250 VAC or 30 VDC |
| With inductive load (cos φ = 0.4 and L/R = 7 ms) |
1.5 A for 250 VAC or 30 VDC |
| Relay 1 |
1 N.O. contact and 1 N.C. contact with a common point |
| Relay 2 |
1 N.O. contact |
| Response time (max.) |
<7 ms ±0.5 ms |
| Output - ACOPOSinverter |
Yes |
| Output - Output |
No |
| Output |
0 to 10 V or 0 to 20 mA |
| Update time |
<2 ms ±0.5 ms |
| Installation elevation above sea level |
0 to 1000 m |
| Degree of protection per EN 60529 |
Upper part: IP21 and IP41Lower part: IP54 (heat sink) |
| Ambient temperature |
-10 to 50°C |
| Max. ambient temperature |
Up to 60°C |
| Relative humidity per IEC 60068-2-3 |
5 to 95%, non-condensingNo dripping water |
| Maximum installation elevation |
Up to 3000 m |
| Max. pollution degree per IEC/EN 61800-5-1 |
2 (non-conductive pollution) |
| Ambient conditions per IEC 60721-3-3 |
Class 3C1 and 3S2 |
| Operating position |
Vertical installation ±10% |
| Storage |
-25 to 70°C |
| Operation |
15 g, 11 ms |
| Width |
240 mm |
| Height |
550 mm |
| Depth |
266 mm |
| Weight |
37 kg |