B&R 8I74T401500.00-000

ACOPOSinverter P74new, 3x 380-500 V, 15 kW, integrated EMC filter and brake chopper, shield plate included in delivery.

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

ACOPOSinverter P74new, 3x 380-500 V, 15 kW, integrated EMC filter and brake chopper, shield plate included in delivery.

Specification

CE

Yes

UL

UL E225616
Power conversion equipment

CSA

CSA E272421
Industrial control equipment

Specified on nameplate

15 kW (20 HP)

Mains input voltage

3x 380 VAC -15% to 500 VAC +10%

Frequency

50 to 60 Hz ±5%

Apparent power (at 500 VAC)

28.8 kVA

Max. assumed short-circuit current (Isc) (short-circuit current at connection point)

22 kA

Inrush current

Max. 36.7 A

At 380 VAC

47.3 A

At 500 VAC

33.3 A

Power dissipation at nominal load and nominal clock frequency

480 W

Integrated EMC filter

Yes

Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network)

C1 level of 2 to 16 kHz with 5 m cable
C1 level of 2 to 8 kHz with 10 m cable
C1 level of 2 to 4 kHz with 20 m cable

Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network)

C2 level of 2 to 16 kHz with 50 m cable
C2 level of 2 to 12 kHz with 100 m cable

Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system)

50 m

With add-on filter

8I0FT049.200-1

Nominal output current

33 A

At nominal clock frequency (4 kHz)

No derating (up to 50°C)

Other clock frequencies

The derating curves are included in the installation instructions, which can be downloaded from http://www.br-automation.com.

Starting at 1000 m above sea level

1%, per 100 m

Max. transient current for 60 s

49.5 A

Max. transient current for 2 s

54.5 A

Output frequency range

0.1 to 599 Hz

Nominal clock frequency

4 kHz

Min.

2 kHz

Max.

16 kHz

With braking resistor

Up to 170% of the nominal motor torque

Shielded cable

50 m

Non-shielded cable

100 m

Induction motor

Sensorless vector control:
1. With V/f characteristic curve for constant torque
→ Default profile
2. With V/f characteristic curve for quadratically increasing torque
→ Energy-saving profile, e.g. for fans and pumps
Sensorless slip control:
1. With V/f characteristic curve for constant torque
→ Default profile
2. With V/f characteristic curve for constant torque (6 f ranges)
→ Profile for individual special applications
3. With V/f characteristic curve for quadratically increasing torque
→ Energy-saving profile, e.g. for fans and pumps

Synchronous motor

Sensorless vector control:
1. With V/f characteristic curve for constant torque
→ Default profile

Main protective functions of inverter

Thermal protection against power stage overheating
Protection against short circuits between motor phases, overcurrent between output phases and ground, overvoltages on the DC bus, exceeding the speed limit. Safety function for: Overvoltage and undervoltage of the mains supply, mains phase failure with 3-phase power supply

Integrated dynamic brake transistors

Yes

Min. resistance value (external)

16 Ω

Input voltage

24 VDC (-15%/+20%)

Current

800 Ω

Output voltage 24 VDC

24 VDC (-15%/+20%)

Max. output current at 24 VDC

100 mA

Output voltage 10 VDC

10 VDC (-0%/+10%)

Max. output current at 10 VDC

10 mA

Type

Type 2

Quantity

1

Nominal voltage

30 VDC / 250 VAC

Input circuit

Sink

Current consumption

16 mA

Input - ACOPOSinverter

Yes

Input - Input

No

Sampling time

2 ms

Input impedance

1.5 kΩ

Max. input frequency

20 kHz

Low

<2 V

High

>17 V

Voltage

470 Ω

Resolution

10-bit

Max. voltage

30 VDC

Output circuit

Source or sink

Max. current

100 mA

Switching capacity

R1, with resistive load (cos phi = 1): 3 A at 250 VAC,
R1, with resistive load (cos phi = 1): 4 A at 30 VDC,
R1, R2, with inductive load (cos = 0.4 and L/R = 7 ms): 2 A at 250 VAC,
R1, R2, with inductive load (cos = 0.4 and L/R = 7 ms): 2 A at 30 VDC,
R2 with resistive load (cos phi = 1): 5 A at 250 VAC,
R2 with resistive load (cos phi = 1): 5 A at 30 VDC

Relay 1

1 changeover contact

Relay 2

1 normally open contact

Output - ACOPOSinverter

Yes

Output - Output

No

Response time (max.)

2 ms

Output

0 to 10 V or 0 to 20 mA

Update time

2 ms

Degree of protection per EN 60529

IP20

Relative humidity per IEC 60068-2-3

5 to 95%. non-condensing
No dripping water

Maximum installation elevation

Up to 2000 m

Max. pollution degree per IEC/EN 61800-5-1

2 (non-conductive pollution)

Ambient conditions per IEC 60721-3-3

Class 3C3 and 3S3

Operating position

Vertical mounting orientation ±10%

Operation

-10 to 50°C without derating
50 to 60°C with derating

Storage

-25 to 70°C

Max. vibration resistance

1 gn 13 to 200 Hz EN/IEC 60068-2-6
1.5 mm peak to peak 3 to 13 Hz EN/IEC 60068-2-6

Width

180 mm

Height

404 mm

Height without shield plate

330 mm

Depth

232 mm

Weight

6.750 kg