B&R 8I74T400750.00-000
ACOPOSinverter P74new, 3x 380-500 V, 7.5 kW, integrated EMC filter and brake chopper, shield plate included in delivery.
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
ACOPOSinverter P74new, 3x 380-500 V, 7.5 kW, integrated EMC filter and brake chopper, shield plate included in delivery.
Specification
| CE |
Yes |
|---|---|
| UL |
UL E225616Power conversion equipment |
| CSA |
CSA E272421Industrial control equipment |
| Specified on nameplate |
7.5 kW (10 HP) |
| Mains input voltage |
3x 380 VAC -15% to 500 VAC +10% |
| Frequency |
50 to 60 Hz ±5% |
| Apparent power (at 500 VAC) |
16.2 kVA |
| Max. assumed short-circuit current (Isc)(short-circuit current at connection point) |
22 kA |
| Inrush current |
Max. 27.6 A |
| At 380 VAC |
26.5 A |
| At 500 VAC |
18.7 A |
| Power dissipation at nominal load and nominal clock frequency |
263 W |
| Integrated EMC filter |
Yes |
| Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network) |
C1 level of 2 to 16 kHz with 10 m cable |
| Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network) |
C2 level of 2 to 16 kHz with 50 m cableC2 level of 2 to 12 kHz with 100 m cable |
| Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system) |
50 m |
| With add-on filter |
8I0FT047.200-1 |
| Nominal output current |
17 A |
| At nominal clock frequency (4 kHz) |
No derating (up to 50°C) |
| Other clock frequencies |
The derating curves are included in the installation instructions, which can be downloaded from http://www.br-automation.com. |
| Starting at 1000 m above sea level |
1%, per 100 m |
| Max. transient current for 60 s |
25.5 A |
| Max. transient current for 2 s |
28 A |
| Output frequency range |
0.1 to 599 Hz |
| Nominal clock frequency |
4 kHz |
| Min. |
2 kHz |
| Max. |
16 kHz |
| With braking resistor |
Up to 170% of the nominal motor torque |
| Shielded cable |
50 m |
| Non-shielded cable |
100 m |
| Induction motor |
Sensorless vector control:1. With V/f characteristic curve for constant torque→ Default profile2. With V/f characteristic curve for quadratically increasing torque→ Energy-saving profile, e.g. for fans and pumpsSensorless slip control:1. With V/f characteristic curve for constant torque→ Default profile2. With V/f characteristic curve for constant torque (6 f ranges)→ Profile for individual special applications3. With V/f characteristic curve for quadratically increasing torque→ Energy-saving profile, e.g. for fans and pumps |
| Synchronous motor |
Sensorless vector control:1. With V/f characteristic curve for constant torque→ Default profile |
| Main protective functions of inverter |
Thermal protection against power stage overheatingProtection against short circuits between motor phases, overcurrent between output phases and ground, overvoltages on the DC bus, exceeding the speed limit. Safety function for: Overvoltage and undervoltage of the mains supply, mains phase failure with 3-phase power supply |
| Integrated dynamic brake transistors |
Yes |
| Min. resistance value (external) |
27 Ω |
| Input voltage |
24 VDC (-15%/+20%) |
| Current |
800 Ω |
| Output voltage 24 VDC |
24 VDC (-15%/+20%) |
| Max. output current at 24 VDC |
100 mA |
| Output voltage 10 VDC |
10 VDC (-0%/+10%) |
| Max. output current at 10 VDC |
10 mA |
| Type |
Type 2 |
| Quantity |
1 |
| Nominal voltage |
30 VDC / 250 VAC |
| Input circuit |
Sink |
| Current consumption |
16 mA |
| Input - ACOPOSinverter |
Yes |
| Input - Input |
No |
| Sampling time |
2 ms |
| Input impedance |
1.5 kΩ |
| Max. input frequency |
20 kHz |
| Low |
<2 V |
| High |
>17 V |
| Voltage |
470 Ω |
| Resolution |
10-bit |
| Max. voltage |
30 VDC |
| Output circuit |
Source or sink |
| Max. current |
100 mA |
| Switching capacity |
R1, with resistive load (cos phi = 1): 3 A at 250 VAC, R1, with resistive load (cos phi = 1): 4 A at 30 VDC, R1, R2, with inductive load (cos = 0.4 and L/R = 7 ms): 2 A at 250 VAC, R1, R2, with inductive load (cos = 0.4 and L/R = 7 ms): 2 A at 30 VDC, R2 with resistive load (cos phi = 1): 5 A at 250 VAC, R2 with resistive load (cos phi = 1): 5 A at 30 VDC |
| Relay 1 |
1 changeover contact |
| Relay 2 |
1 normally open contact |
| Output - ACOPOSinverter |
Yes |
| Output - Output |
No |
| Response time (max.) |
2 ms |
| Output |
0 to 10 V or 0 to 20 mA |
| Update time |
2 ms |
| Degree of protection per EN 60529 |
IP20 |
| Relative humidity per IEC 60068-2-3 |
5 to 95%. non-condensingNo dripping water |
| Maximum installation elevation |
Up to 2000 m |
| Max. pollution degree per IEC/EN 61800-5-1 |
2 (non-conductive pollution) |
| Ambient conditions per IEC 60721-3-3 |
Class 3C3 and 3S3 |
| Operating position |
Vertical mounting orientation ±10% |
| Operation |
-10 to 50°C without derating50 to 60°C with derating |
| Storage |
-25 to 70°C |
| Max. vibration resistance |
1 gn 13 to 200 Hz EN/IEC 60068-2-61.5 mm peak to peak 3 to 13 Hz EN/IEC 60068-2-6 |
| Width |
150 mm |
| Height |
308 mm |
| Height without shield plate |
232 mm |
| Depth |
232 mm |
| Weight |
4.20 kg |