Fast delivery within 72 Hours
B&R 8I66T400220.00-000
Base device for ACOPOSinverter P66 and P64new, 3 x 380 to 500 V, 2.2 kW, integrated EMC filter and brake chopper, shield plate included in deliveryOrder number – ACOPOSinverter P66: 8I66T400220.0P-000…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Base device for ACOPOSinverter P66 and P64new, 3 x 380 to 500 V, 2.2 kW, integrated EMC filter and brake chopper, shield plate included in deliveryOrder number – ACOPOSinverter P66: 8I66T400220.0P-000: Inverter with POWERLINK communication card8I66T400220.0X-000: Inverter with X2X Link communication card8I66T400220.0C-000: Inverter with integrated CANopen interface Order number – ACOPOSinverter P64new: Â 8I64T400220.0X-000: Inverter with X2X Link communication card
Specification
| CE |
Yes |
|---|---|
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| UL |
cULus E225616 |
| KC |
Yes |
| Specified on nameplate |
2.2 kW (3 HP) |
| Mains input voltage |
3x 380 VAC -15% to 500 VAC +10% |
| Frequency |
50 to 60 Hz ±5% |
| Apparent power (at 500 VAC) |
5.3 kVA |
| Max. assumed short-circuit current (Isc) (short-circuit current at connection point) |
5 kA |
| Inrush current |
Max. 10 A |
| At 380 VAC |
8 A |
| At 500 VAC |
6.1 A |
| Power dissipation at nominal load and nominal clock frequency |
76 W |
| Integrated EMC filter |
Yes |
| Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network) |
50 m |
| Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system) |
100 m |
| With add-on filter |
8I0FT025.200-1 |
| Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network) |
20 m |
| Nominal output current |
5.5 A |
| At nominal clock frequency (4 kHz) |
No derating (up to 50°C) |
| Other clock frequencies |
The derating curves are included in the installation instructions, which can be downloaded from the website (www.br-automation.com). |
| Starting at 1000 m above sea level |
1%, per 100 m |
| Max. transient current for 60 s |
8.3 A |
| Output frequency range |
0.1 to 599 Hz |
| Nominal clock frequency |
4 kHz |
| Min. |
2 kHz |
| Max. |
16 kHz |
| With braking resistor |
Up to 170% of the rated motor torque |
| Shielded cable |
50 m |
| Non-shielded cable |
100 m |
| Induction motor |
Sensorless vector control: |
| Synchronous motor |
Sensorless vector control: |
| Main protective functions of inverter |
Thermal protection against power stage overheating |
| Integrated dynamic brake transistors |
Yes |
| Min. resistance value (external) |
54 Ω |
| Input voltage |
24 VDC (-15%/+20%) |
| Current |
800 Ω |
| Output voltage 24 VDC |
24 VDC (-15%/+20%) |
| Max. output current at 24 VDC |
100 mA |
| Output voltage 10 VDC |
10 VDC (-0%/+10%) |
| Max. output current at 10 VDC |
10 mA |
| Type |
Type 3 |
| Quantity |
1 |
| Nominal voltage |
30 VDC / 250 VAC |
| Input circuit |
Source or sink |
| Switching threshold |
Sink: >19 V (position 0), <13 V (position 1) |
| Input - ACOPOSinverter |
Yes |
| Input - Input |
No |
| Sampling time |
2 ms |
| Max. input frequency |
20 kHz |
| Input impedance |
1.5 kΩ |
| Current consumption |
16 mA |
| Nonlinearity |
±0.3% |
| Basic accuracy |
At 25°C: ±1% |
| Voltage |
470 Ω |
| Resolution |
10-bit |
| Max. voltage |
30 VDC |
| Output circuit |
Source or sink |
| Max. current |
100 mA |
| Switching current range |
Min. switching current: 5 mA at 24 VDC |
| Relay 1 |
1 changeover contact |
| Relay 2 |
1 normally open contact |
| Output - ACOPOSinverter |
Yes |
| Output - Output |
No |
| Response time (max.) |
2 ms |
| Output |
0 to 10 V or 0 to 20 mA |
| Update time |
2 ms |
| Power dissipation relative to continuous apparent power |
IE2 (10, 25): 0.9% (3x 380 VAC), 0.8% (3x 500 VAC) |
| Nominal losses in standby mode |
8 W (3x 380 VAC), 10 W (3x 500 VAC) |
| Degree of protection per EN 61800-5-1 |
IP20 |
| Relative humidity per IEC 60068-2-3 |
5 to 95%, non-condensing |
| Maximum installation elevation |
≤1000 m without derating |
| Max. pollution degree per IEC/EN 61800-5-1 |
2 (non-conductive pollution) |
| Ambient conditions per IEC 60721-3-3 |
Class 3C3 and 3S2 |
| Operating position |
Vertical mounting orientation ±10° |
| Operation |
-10 to 50°C without derating |
| Storage |
-25 to 70°C |
| Max. vibration resistance |
1 gn 13 to 200 Hz EN/IEC 60068-2-6 |
| Width |
140 mm |
| Height |
228 mm |
| Height without shield plate |
184 mm |
| Depth |
158 mm |
| Weight |
2.1 kg |

Reviews
Clear filtersThere are no reviews yet.