B&R 8I66T200750.00-000

Base device for ACOPOSinverter P66 and P64new, 3 x 200 to 240 V, 7.5 kW, integrated brake chopperOrder number – ACOPOSinverter P66: 8I66T200750.0P-000: Inverter with POWERLINK communication card8I66T2…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

Base device for ACOPOSinverter P66 and P64new, 3 x 200 to 240 V, 7.5 kW, integrated brake chopperOrder number – ACOPOSinverter P66: 8I66T200750.0P-000: Inverter with POWERLINK communication card8I66T200750.0X-000: Inverter with X2X Link communication card8I66T200750.0C-000: Inverter with integrated CANopen interface Order number – ACOPOSinverter P64new: 8I64T200750.0X-000: Inverter with X2X Link communication card

Specification

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

UL

cULus E225616
Power conversion equipment

Specified on nameplate

7.5 kW (10 HP)

Mains input voltage

3x 200 VAC -15% to 240 VAC +10%

Frequency

50 to 60 Hz ±5%

Apparent power (at 240 VAC)

15.3 kVA

Max. assumed short-circuit current (Isc) (short-circuit current at connection point)

22 kA

Inrush current

35.2 A

At 200 VAC

43.8 A

At 240 VAC

36.9 A

Power dissipation at nominal load and nominal clock frequency

324 W

Integrated EMC filter

No

Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network)

1 m

Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network)

5 m

Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system)

5 m

Nominal output current

33 A

At nominal clock frequency (4 kHz)

No derating (up to 50°C)

Other clock frequencies

The derating curves are included in the installation instructions, which can be downloaded from the website (www.br-automation.com).

Starting at 1000 m above sea level

1%, per 100 m

Max. transient current for 60 s

49.5 A

Output frequency range

0.1 to 599 Hz

Nominal clock frequency

4 kHz

Min.

2 kHz

Max.

16 kHz

With braking resistor

Up to 170% of the rated motor torque

Shielded cable

50 m

Non-shielded cable

100 m

Induction motor

Sensorless vector control:
1. Voltage controlled with constant torque → standard mode
2. Voltage controlled with variable torque → energy saving mode e.g. for fans and pumps
Sensorless slip control:
1. With V/f characteristic curve for constant torque → standard mode
2. With V/f characteristic curve for constant torque (up to 6 f-ranges) → Custom mode for special applications
3. With V/f characteristic curve for quadratically increasing torque → Energy-saving mode, e.g. for fans and pumps

Synchronous motor

Sensorless vector control:
1. Voltage controlled with constant torque → standard mode

Main protective functions of inverter

Thermal protection against power stage overheating
Protection against short circuits between motor phases, overcurrent between output phases and ground, overvoltages on the DC bus, exceeding the speed limit.
Safety function for: Overvoltage and undervoltage of the mains supply, mains phase failure with 3-phase power supply

Integrated dynamic brake transistors

Yes

Min. resistance value (external)

8 Ω

Input voltage

24 VDC (-15%/+20%)

Current

800 Ω

Output voltage 24 VDC

24 VDC (-15%/+20%)

Max. output current at 24 VDC

100 mA

Output voltage 10 VDC

10 VDC (-0%/+10%)

Max. output current at 10 VDC

10 mA

Type

Type 3

Quantity

1

Nominal voltage

30 VDC / 250 VAC

Input circuit

Source or sink

Switching threshold

Sink: >19 V (position 0), <13 V (position 1)
Source: <5 V (position 0), >11 V (position 1)

Input - ACOPOSinverter

Yes

Input - Input

No

Sampling time

2 ms

Max. input frequency

20 kHz

Input impedance

1.5 kΩ

Current consumption

16 mA

Nonlinearity

±0.3%

Basic accuracy

At 25°C: ±1%
At -10 to 60°C: ±2%

Voltage

470 Ω

Resolution

10-bit

Max. voltage

30 VDC

Output circuit

Source or sink

Max. current

100 mA

Switching current range

Min. switching current: 5 mA at 24 VDC
Max. switching current:
R1 at cos φ = 1: 3 A at 250 VAC / 4 A at 30 VDC
R2 at cos φ = 1: 5 A
R1 and R2 at cos φ = 0.4: 2 A

Relay 1

1 changeover contact

Relay 2

1 normally open contact

Output - ACOPOSinverter

Yes

Output - Output

No

Response time (max.)

2 ms

Output

0 to 10 V or 0 to 20 mA

Update time

2 ms

Power dissipation relative to continuous apparent power

IE2 (10, 25): 0.7% (3x 200 VAC), 0.7% (3x 240 VAC)
IE2 (50, 25): 0.7% (3x 200 VAC), 0.6% (3x 240 VAC)
IE2 (10, 50): 1.1% (3x 200 VAC), 0.9% (3x 240 VAC)
IE2 (50, 50): 1% (3x 200 VAC), 0.9% (3x 240 VAC)
IE2 (90, 50): 1.2% (3x 200 VAC), 1% (3x 240 VAC)
IE2 (10, 100): 2% (3x 200 VAC), 1.8% (3x 240 VAC)
IE2 (50, 100): 2% (3x 200 VAC), 1.7% (3x 240 VAC)
IE2 (90, 100): 2.4% (3x 200 VAC), 2% (3x 240 VAC)

Nominal losses in standby mode

7 W

Degree of protection per EN 61800-5-1

IP20

Relative humidity per IEC 60068-2-3

5 to 95%, non-condensing
No dripping water

Maximum installation elevation

≤1000 m without derating
1000 to 3000 m with Derating

Max. pollution degree per IEC/EN 61800-5-1

2 (non-conductive pollution)

Ambient conditions per IEC 60721-3-3

Class 3C3 and 3S2

Operating position

Vertical mounting orientation ±10°

Operation

-10 to 50°C without derating
50 to 60°C with derating

Storage

-25 to 70°C

Max. vibration resistance

1 gn 13 to 200 Hz EN/IEC 60068-2-6
1.5 mm peak to peak 2 to 13 Hz EN/IEC 60068-2-6

Width

150 mm

Height

308 mm

Height without shield plate

232 mm

Depth

178 mm

Weight

3.6 kg