Fast delivery within 72 Hours

B&R 8EI2X2HWT10.0600-1

ACOPOS P3 servo drive, 1 digital multi-standard encoder interface per axis, 3x 200-480 VAC, 2.2 A, 3 axes, wall mounting, 1-row connector set, cover, integrated braking resistor

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

ACOPOS P3 servo drive, 1 digital multi-standard encoder interface per axis, 3x 200-480 VAC, 2.2 A, 3 axes, wall mounting, 1-row connector set, cover, integrated braking resistor

Specification

Dynamic node allocation (DNA)Yes
Slots for plug-in modules1
Network configurationsTN-S, TN-C-S with grounded neutral
Mains input voltage3x 200 VAC to 480 VAC ±10%
Frequency50 / 60 Hz ±4%
Installed loadMax. 7.5 kVA
Inrush currentMax. 45 A
Switch-on intervalTyp. 60 s
Integrated line filter per EN 61800-3, category C3No
Power dissipation at device nominal power without braking resistor[(60 + 6.9 * PAVG [kW] + 7.5 * (IAX1 [A] + IAX2 [A] + IAX3 [A]) + 0.25 * (IBR12 [A] + IBR22 [A] + IBR32 [A]) + PVSLOT) * 1.1] [W]
DC bus capacitance470 µF
Input voltage24 VDC ±25%
Input capacitance5507 µF
Current consumption1.2 A + Current for motor holding brake
Quantity3
Continuous power per motor connection1 / 1 / 1 kW
Continuous current per motor connection2.2 / 2.2 / 2.2 Aeff
Switching frequency 5 kHz75 m
Switching frequency 10 kHz37.5 m
Switching frequency 20 kHz18.75 m
Starting at 500 m above sea level0.22 Aeff per 1000 m
Peak current per motor connection6 / 6 / 6 Aeff
Peak power output2.5 kW
Nominal switching frequency5 kHz
Possible switching frequencies5 / 10 / 20 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004Limit value curve A
Overload protectionYes
Short-circuit and ground fault protectionYes
Max. output frequency598 Hz
U, V, W, PEConnector
Shield connectionYes
With wire end sleeve1.5 to 6 mm²
UL/C-UL-US24 to 8 AWG
CSA24 to 8 AWG
Output voltageTyp. 11.4 V
Continuous current per connection1.3 A
Max. internal resistance0.25 Ω
Extinction potentialApprox. 30 V
Max. extinction energy per switching operation1.5 Ws
Max. switching frequency0.5 Hz
Overload and short-circuit protectionYes
Open-circuit monitoringYes
Undervoltage monitoringYes
Response threshold for open-circuit monitoringApprox. 30 mA
Peak power int./ext.7 kW / 25 kW
Continuous power int./ext.150 W / 2 kW
Minimum braking resistance (ext.)25 Ω
CircuitSink
Input - ACOPOS P3Yes
Input - InputYes
Nominal5 to 40°C
Maximum55°C
Input current at nominal voltageApprox. 4 mA
Low<5 V
High>15 V
Enable 1 → 0, PWM off2 ms
Enable 0 → 1, ready for PWM0.3 ms
Modulation compared to ground potentialMax. ±38 V
OSSD signal connections0.5 ms
TypeEnDat 2.2
Connections8-pin female Mini I/O connector
Status indicatorsNone
Encoder - ACOPOS P3No
Encoder monitoringNo
Max. encoder cable length100 m Depends on the cross section of the power supply wires in the encoder cable
Load capacity300 mA
Short-circuit proofYes
Overload-proofYes
Signal transmissionRS485
Data transfer rate6.25 Mbit/s
Max. power consumption per encoder interfacePENCODER [W] = U24V [V] * (IENCODER [A] * 0.7) + 0.5 W
Rising edge<2 µs
Falling edge<1 µs
Resistance range500 Ω to 5 kΩ
ACP10V3.12.1
Hanging verticallyYes
Standing horizontallyIn preparation
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Storage5 to 95%
Transport95% at 40°C
Operation5 to 85%, non-condensing
Width66 mm
Height374 mm
Wall mounting258.5 mm (with 8EXA front cover: 261 mm)
Weight4 kg

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R 8EI2X2HWT10.0600-1”