B&R 8EI2X2HWSS0.XXXX-1
ACOPOS P3 servo drive, 3x 200-480 VAC, 2.2 A, SafeMOTION, 1 axis, wall mounting
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
ACOPOS P3 servo drive, 3x 200-480 VAC, 2.2 A, SafeMOTION, 1 axis, wall mounting
Specification
| Dynamic node allocation (DNA) | Yes |
|---|---|
| Slots for plug-in modules | 1 |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| UL | cULus E225616 Power conversion equipment |
| KC | Yes |
| Network configurations | TT, TN, TN-S, TN-C-S, IT |
| Mains input voltage | 3x 200 VAC to 480 VAC ±10% 24 to 120 VDC |
| Frequency | 50 / 60 Hz ±4% |
| Installed load | Max. 2.5 kVA |
| Inrush current | Max. 45 A |
| Switch-on interval | Typ. 60 s |
| Integrated line filter per EN 61800-3, category C3 | No |
| With wire end sleeve | 0.25 to 2.5 mm² |
| UL/C-UL-US | 26 to 12 AWG |
| CSA | 26 to 12 AWG |
| Power dissipation at device nominal power without braking resistor | [(40 + 6.9 * PAVG [kW] + 7.5 * IAX1 [A] + 0.25 * IBR12 [A] + PVSLOT) * 1.1] [W] |
| Max. line length | 100 m |
| Continuous power | 1 kW |
| Mains input voltage <3x 400 VAC | 1 kW * (Mains input voltage [V] / 400 V) |
| DC bus capacitance | 470 µF |
| With wire end sleeves | 0.25 to 4 mm² |
| Input voltage | 24 VDC ±25% |
| Input capacitance | 5500 µF |
| Current consumption | 0.9 A + Current for motor holding brake |
| Quantity | 1 |
| Continuous power per motor connection | 1 kW |
| Continuous current per motor connection | 2.2 Aeff |
| SIL 2 / PL d / Cat. 3 | Hardware upgrade 1.10.2.x: 1.441 A Hardware upgrade 1.10.3.0 or later: 1.136 A |
| SIL 2 / PL d / Cat. 2 | 0.470 A |
| Switching frequency 5 kHz | 75 m |
| Switching frequency 10 kHz | 38 m |
| Switching frequency 20 kHz | 19 m |
| Starting at 500 m above sea level | 0.22 Aeff per 1000 m |
| Peak current per motor connection | 6 Aeff |
| Peak power output | 2.5 kW |
| Nominal switching frequency | 5 kHz |
| Possible switching frequencies | 2.5 / 5 / 10 / 20 kHz |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 | Limit value curve A |
| Overload protection | No |
| Short-circuit and ground fault protection | Short-circuit protection: Yes Ground fault protection: No |
| Max. output frequency | 598 Hz |
| U, V, W, PE | Connector |
| Shield connection | Yes Clamping range of the grounding clamp: 11 to 16 mm |
| Output voltage | Configurable Typ. 11.45 V ±0.1 V / 5.2 V ±0.1 V |
| Continuous current per connection | 1.3 A |
| Max. internal resistance | 0.25 Ω |
| Extinction potential | Approx. 30 V |
| Max. extinction energy per switching operation | 1.5 Ws |
| Max. switching frequency | 0.5 Hz |
| Overload and short-circuit protection | Yes |
| Open-circuit monitoring | Yes |
| Undervoltage monitoring | Yes |
| Response threshold for open-circuit monitoring | Approx. 30 mA |
| Response threshold for undervoltage monitoring | Approx. 23 V |
| Max. breaking current SBC | 60 mA |
| Peak power int./ext. | 7 kW / 25 kW |
| Continuous power int./ext. | 100 W / 2 kW |
| Minimum braking resistance (ext.) | 25 Ω |
| Type | Digital multi-encoder interface, configurable |
| Variant | 2x RJ45, shielded, 2-port hub |
| Line length | Max. 100 m between 2 stations (segment length) |
| Transfer rate | 100 Mbit/s |
| Connections | 8-pin female Mini I/O connector |
| Status indicators | None |
| Encoder - ACOPOS P3 | No |
| Max. encoder cable length | 75 m Depends on the cross section of the power supply wires in the encoder cable |
| Load capacity | Max. 300 mA |
| Sense lines | 2, compensation of max. 2x 0.7 V |
| Short-circuit proof | Yes |
| Overload-proof | Yes |
| Signal transmission | RS485 |
| Data transfer rate | Depends on the configured encoder type |
| Minimum | -25°C |
| Maximum | 55°C |
| Max. power consumption per encoder interface | PENCODER [W] = U24V [V] * (IENCODER [A] * 0.7) + 0.5 W |
| Circuit | Sink |
| Input - ACOPOS P3 | Yes |
| Input - Input | Yes |
| Nominal | 5 to 40°C |
| Low | <5 V |
| High | >15 V |
| Input current at nominal voltage | 7 mA |
| Rising edge | <51 µs |
| Falling edge | <52 µs |
| Modulation compared to ground potential | Max. ±38 V |
| Resistance range | 500 Ω to 5 kΩ |
| Mapp Motion | 5.03.0 and higher |
| ACP10/ARNC0 | 3.16.1 and higher |
| Power dissipation relative to continuous apparent power | IE2 (10,25) 3.3% IE2 (50,25) 3.3% IE2 (10,50) 3.5% IE2 (50,50) 3.5% IE2 (90,50) 3.6% IE2 (10,100) 3.8% IE2 (50,100) 3.9% IE2 (90,100) 4.1% |
| Nominal losses in standby mode | 11.8 W |
| Hanging vertically | Yes |
| Standing horizontally | Yes |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Degree of protection per EN 60529 | IP20 |
| Storage | 5 to 95% |
| Transport | 95% at 40°C |
| Operation | 5 to 85%, non-condensing |
| Width | 66 mm |
| Height | 290 mm |
| Wall mounting | 258.5 mm (with 8EXA front cover: 261 mm) |
| Weight | 3.2 kg |
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0