Fast delivery within 72 Hours

B&R 8EI2X2HCSS0.XXXX-1

ACOPOS P3 servo drive, 3x 200-480 VAC, 2.2 A, SafeMOTION, 1 axis, AS, cold plate or pass-through mounting

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

ACOPOS P3 servo drive, 3x 200-480 VAC, 2.2 A, SafeMOTION, 1 axis, AS, cold plate or pass-through mounting

Specification

Dynamic node allocation (DNA)

Yes

Slots for plug-in modules

1

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

UL

cULus E225616Power conversion equipment

KC

In preparation

Network configurations

TT, TN, TN-S, TN-C-S, IT

Mains input voltage

3x 200 VAC to 480 VAC ±10%24 to 120 VDC

Frequency

50 / 60 Hz ±4%

Installed load

Max. 2.5 kVA

Inrush current

Max. 45 A

Switch-on interval

Typ. 60 s

Integrated line filter per EN 61800-3, category C3

No

With wire end sleeve

0.25 to 2.5 mm²

UL/C-UL-US

26 to 12 AWG

CSA

26 to 12 AWG

Power dissipation at device nominal power without braking resistor

[(40 + 6.9 * PAVG [kW] + 7.5 * IAX1 [A] + 0.25 * IBR12 [A] + PVSLOT) * 1.1] [W]

Power dissipation remaining in the control cabinet

Pv_inside = 0.58*Pv+1.6*(T_amb – T_inside)

Max. line length

100 m

Continuous power

2 kW

Mains input voltage <3x 400 VAC

1 kW * (Mains input voltage [V] / 400 V)

DC bus capacitance

470 µF

With wire end sleeves

0.25 to 4 mm²

Input voltage

24 VDC ±25%

Input capacitance

4310 µF

Current consumption

0.9 A + Current for motor holding brake

Quantity

1

Continuous power per motor connection

1 kW

Continuous current per motor connection

2.2 Aeff

Switching frequency 5 kHz

75 m

Switching frequency 10 kHz

38 m

Switching frequency 20 kHz

19 m

Starting at 500 m above sea level

0.22 Aeff per 1000 m

Peak current per motor connection

6 Aeff

Peak power output

25 kW

Nominal switching frequency

5 kHz

Possible switching frequencies

2.5 / 5 / 10 / 20 kHz

Insulation stress of the connected motor per IEC TS 60034-25:2004

Limit value curve A

Overload protection

No

Short-circuit and ground fault protection

Short-circuit protection: YesGround fault protection: No

Max. output frequency

598 Hz

U, V, W, PE

Connector

Shield connection

YesClamping range of the grounding clamp: 11 to 16 mm

Output voltage

ConfigurableTyp. 11.45 V ±0.1 V / 5.2 V ±0.1 V

Continuous current per connection

1.3 A

Max. internal resistance

0.25 Ω

Extinction potential

Approx. 30 V

Max. extinction energy per switching operation

1.5 Ws

Max. switching frequency

0.5 Hz

Overload and short-circuit protection

Yes

Open-circuit monitoring

Yes

Undervoltage monitoring

Yes

Response threshold for open-circuit monitoring

Approx. 30 mA

Response threshold for undervoltage monitoring

Approx. 23 V

Minimum braking resistance (ext.)

25 Ω

Type

Digital multi-encoder interface, configurable

Variant

2x RJ45, shielded, 2-port hub

Line length

Max. 100 m between 2 stations (segment length)

Transfer rate

100 Mbit/s

Connections

8-pin female Mini I/O connector

Status indicators

None

Encoder - ACOPOS P3

No

Max. encoder cable length

75 m Depends on the cross section of the power supply wires in the encoder cable

Load capacity

Max. 300 mA

Short-circuit proof

Yes

Overload-proof

Yes

Signal transmission

RS485

Data transfer rate

Depends on the configured encoder type

Minimum

-25°C

Maximum

55°C

Max. power consumption per encoder interface

PENCODER [W] = U24V [V] * (IENCODER [A] * 0.7) + 0.5 W

Circuit

Sink

Input - ACOPOS P3

Yes

Input - Input

Yes

Nominal

5 to 40°C

Low

<5 V

High

>15 V

Input current at nominal voltage

7 mA

Rising edge

<51 µs

Falling edge

<52 µs

Modulation compared to ground potential

Max. ±38 V

Resistance range

500 Ω to 5 kΩ

Mapp Motion

5.05.0 and higher

ACP10/ARNC0

3.16.1 and higher

Power dissipation relative to continuous apparent power

IE2 (10,25) 3.3% IE2 (50,25) 3.3% IE2 (10,50) 3.5% IE2 (50,50) 3.5% IE2 (90,50) 3.6% IE2 (10,100) 3.8% IE2 (50,100) 3.9% IE2 (90,100) 4.1%

Nominal losses in standby mode

11.8 W

Hanging vertically

Yes

Horizontal, face up

No

Standing horizontally

No

Pollution degree per EN 61800-5-1

2 (non-conductive pollution)

Overvoltage category per EN 61800-5-1

III

Degree of protection per EN 60529

IP20

Storage

5 to 95%

Transport

95% at 40°C

Operation

5 to 85 %, non-condensing

Width

66 mm

Height

290 mm

Depth

264.50 mm (with 8EXA front cover: 267 mm)

Weight

3.8 kg

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R 8EI2X2HCSS0.XXXX-1”