B&R 8EI024HCSS0.XXXX-1

ACOPOS P3 servo drive, 3x 200-480 VAC, 24 A, SafeMOTION, 1 axis, AS, cold plate or pass-through mounting

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

ACOPOS P3 servo drive, 3x 200-480 VAC, 24 A, SafeMOTION, 1 axis, AS, cold plate or pass-through mounting

Specification

Dynamic node allocation (DNA)Yes
Slots for plug-in modules1
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ULcULus E225616 Power conversion equipment
Network configurationsTT, TN, TN-S, TN-C-S, IT
Mains input voltage3x 200 VAC to 480 VAC ±10%
Frequency50 / 60 Hz ±4%
Installed loadMax. 18.7 kVA
Inrush currentMax. 100 A
Switch-on interval120 s
Integrated line filter per EN 61800-3, category C3No
With wire end sleeve0.25 to 2.5 mm²
UL/C-UL-US26 to 12 AWG
CSA26 to 12 AWG
Power dissipation at device nominal power without braking resistor[81 W + 9.7 V * I + 8.4 W/kW * Pout + 0.25 Ω * I2BR + PVSLOT] * 1.1
Power dissipation remaining in the control cabinetPv_inside = 0.510 * Pv + 1.624 * (T_amb – T_inside)
Max. line length100 m
Continuous power4 kW
Mains input voltage <3x 400 VAC10 kW * (Mains input voltage [V] / 400 V)
DC bus capacitance1680 µF
With wire end sleeves0.25 to 4 mm²
Input voltage24 VDC ±25%
Input capacitance5500 μF
Current consumption2 A + Current for motor holding brake
Quantity1
Continuous power per motor connection10 kW
Continuous current per motor connection24 Aeff
SIL 2 / PL d / Cat. 3Hardware upgrade 1.10.2.x: 7.489 A Hardware upgrade 1.10.3.0 or later: 5.944 A
SIL 2 / PL d / Cat. 22.498 A
Switching frequency 5 kHz75 m
Switching frequency 10 kHz35 m
Switching frequency 20 kHz20 m
Starting at 500 m above sea level2.4 Aeff per 1000 m
Peak current per motor connection60 Aeff
Peak power output45 kW
Nominal switching frequency5 kHz
Possible switching frequencies2.5 / 5 / 10 / 20 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004Limit value curve A
Overload protectionNo
Short-circuit and ground fault protectionShort-circuit protection: Yes Ground fault protection: No
Max. output frequency598 Hz
U, V, W, PEConnector
Shield connectionYes Clamping range of the grounding clamp: 17 to 30 mm
Output voltageConfigurable Typ. 11.45 V ±0.1 V / 5.2 V ±0.1 V
Continuous current per connection6.5 A
Max. internal resistance0.25 Ω
Extinction potentialApprox. 30 V
Max. extinction energy per switching operation15 Ws
Max. switching frequency0.5 Hz
Overload and short-circuit protectionYes
Open-circuit monitoringYes
Undervoltage monitoringYes
Response threshold for open-circuit monitoringApprox. 120 mA
Response threshold for undervoltage monitoringApprox. 23 V
Max. breaking current SBC200 mA
Minimum braking resistance (ext.)13 Ω
TypeDigital multi-encoder interface, configurable
Variant2x RJ45, shielded, 2-port hub
Line lengthMax. 100 m between 2 stations (segment length)
Transfer rate100 Mbit/s
Connections8-pin female Mini I/O connector
Status indicatorsNone
Encoder - ACOPOS P3No
Max. encoder cable length75 m Depends on the cross section of the power supply wires in the encoder cable
Load capacityMax. 300 mA
Sense lines2, compensation of max. 2x 0.7 V
Short-circuit proofYes
Overload-proofYes
Signal transmissionRS485
Data transfer rateDepends on the configured encoder type
Minimum-25°C
Maximum55°C
Max. power consumption per encoder interfacePENCODER [W] = U24V [V] * (IENCODER [A] * 0.7) + 0.5 W
CircuitSink
Input - ACOPOS P3Yes
Input - InputYes
Nominal5 to 40°C
Low<5 V
High>15 V
Input current at nominal voltage7 mA
Rising edge<51 µs
Falling edge<52 µs
Modulation compared to ground potentialMax. ±38 V
Resistance range500 Ω to 5 kΩ
Mapp Motion5.05.0 and higher
ACP10/ARNC05.03.0 and higher
Power dissipation relative to continuous apparent powerIE2 (10,25) 1.2% IE2 (50,25) 1.2% IE2 (10,50) 1.4% IE2 (50,50) 1.4% IE2 (90,50) 1.5% IE2 (10,100) 2% IE2 (50,100) 2.2% IE2 (90,100) 2.4%
Nominal losses in standby mode15.8 W
Hanging verticallyYes
Horizontal, face upNo
Standing horizontallyNo
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Storage5 to 95%
Transport95% at 40°C
Operation5 to 85 %, non-condensing
Width133 mm
Height374 mm
Depth264.50 mm (with 8EXA front cover: 267 mm)
Cold plate281.5 mm (with 8EXA front cover: 284 mm)
Pass-through mounting277.5 mm (with 8EXA front cover: 280 mm)
Weight9.4 kg