ACOPOS P3 servo drive, 3x 200-480 VAC, 2x 17 A, SafeMOTION, 2 axes, AS, cold plate or pass-through mounting
Specification
| Dynamic node allocation (DNA) |
Yes |
|---|---|
| Slots for plug-in modules |
1 |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| UL |
cULus E225616Power conversion equipment |
| KC |
In preparation |
| Network configurations |
TT, TN, TN-S, TN-C-S, IT |
| Mains input voltage |
3x 200 VAC to 480 VAC ±10% |
| Frequency |
50 / 60 Hz ±4% |
| Installed load |
Max. 26.4 kVA |
| Inrush current |
100 A |
| Switch-on interval |
120 s |
| Integrated line filter per EN 61800-3, category C3 |
No |
| With wire end sleeve |
0.25 to 2.5 mm² |
| UL/C-UL-US |
26 to 12 AWG |
| CSA |
26 to 12 AWG |
| Power dissipation at device nominal power without braking resistor |
[80 W + 9.1 V * (I1 + I2) + 6.5 W/kW * Pout + 0.25 Ω * (I2BR1 + I2BR2) + PVSLOT] * 1.1 |
| Power dissipation remaining in the control cabinet |
Pv_inside = 0.510 * Pv + 1.624 * (T_amb – T_inside) |
| Max. line length |
100 m |
| Continuous power |
4 kW |
| Mains input voltage <3x 400 VAC |
14 kW * (Mains input voltage [V] / 400 V) |
| DC bus capacitance |
1680 µF |
| With wire end sleeves |
0.25 to 4 mm² |
| Input voltage |
24 VDC ±25% |
| Input capacitance |
5500 µF |
| Current consumption |
2.4 A + Current for motor holding brake |
| Quantity |
2 |
| Continuous power per motor connection |
7 / 7 kW |
| Continuous current per motor connection |
17 / 17 Aeff |
| Switching frequency 5 kHz |
75 m |
| Switching frequency 10 kHz |
75 m |
| Switching frequency 20 kHz |
30 m |
| Starting at 500 m above sea level |
1.7 Aeff per 1000 m |
| Peak current per motor connection |
42.5 / 42.5 Aeff |
| Peak power output |
45 kW |
| Nominal switching frequency |
5 kHz |
| Possible switching frequencies |
2.5 / 5 / 10 / 20 kHz |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 |
Limit value curve A |
| Overload protection |
No |
| Short-circuit and ground fault protection |
Short-circuit protection: YesGround fault protection: No |
| Max. output frequency |
598 Hz |
| U, V, W, PE |
Connector |
| Shield connection |
YesClamping range of the grounding clamp: 17 to 30 mm |
| Output voltage |
ConfigurableTyp. 11.45 V ±0.1 V / 5.2 V ±0.1 V |
| Continuous current per connection |
4 A |
| Max. internal resistance |
0.25 Ω |
| Extinction potential |
33 V |
| Max. extinction energy per switching operation |
15 Ws |
| Max. switching frequency |
0.5 Hz |
| Overload and short-circuit protection |
Yes |
| Open-circuit monitoring |
Yes |
| Undervoltage monitoring |
Yes |
| Response threshold for open-circuit monitoring |
Max. 70 mA |
| Response threshold for undervoltage monitoring |
Approx. 23 V |
| Max. breaking current SBC |
80 mA |
| Minimum braking resistance (ext.) |
13 Ω |
| Type |
Digital multi-encoder interface, configurable |
| Variant |
2x RJ45, shielded, 2-port hub |
| Line length |
Max. 100 m between 2 stations (segment length) |
| Transfer rate |
100 Mbit/s |
| Connections |
8-pin female Mini I/O connector |
| Status indicators |
None |
| Encoder - ACOPOS P3 |
No |
| Max. encoder cable length |
75 m Depends on the cross section of the power supply wires in the encoder cable |
| Load capacity |
Max. 300 mA |
| Short-circuit proof |
Yes |
| Overload-proof |
Yes |
| Signal transmission |
RS485 |
| Data transfer rate |
Depends on the configured encoder type |
| Minimum |
-25°C |
| Maximum |
55°C |
| Max. power consumption per encoder interface |
PENCODER [W] = U24V [V] * (IENCODER [A] * 0.7) + 0.5 W |
| Circuit |
Sink |
| Input - ACOPOS P3 |
Yes |
| Input - Input |
Yes |
| Nominal |
5 to 40°C |
| Low |
<5 V |
| High |
>15 V |
| Input current at nominal voltage |
7 mA |
| Rising edge |
<51 µs |
| Falling edge |
<52 µs |
| Modulation compared to ground potential |
Max. ±38 V |
| Resistance range |
500 Ω to 5 kΩ |
| Mapp Motion |
5.05.0 and higher |
| ACP10/ARNC0 |
5.03.0 and higher |
| Power dissipation relative to continuous apparent power |
IE2 (10,25) 1.4% IE2 (50,25) 1.5% IE2 (10,50) 1.6% IE2 (50,50) 1.7% IE2 (90,50) 1.8% IE2 (10,100) 2.3% IE2 (50,100) 2.4% IE2 (90,100) 2.7% |
| Nominal losses in standby mode |
16.3 W |
| Hanging vertically |
Yes |
| Horizontal, face up |
No |
| Standing horizontally |
No |
| Pollution degree per EN 61800-5-1 |
2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 |
III |
| Degree of protection per EN 60529 |
IP20 |
| Storage |
5 to 95% |
| Transport |
95% at 40°C |
| Operation |
5 to 85%, non-condensing |
| Width |
133 mm |
| Height |
374 mm |
| Depth |
264.50 mm (with 8EXA front cover: 267 mm) |
| Weight |
In preparation |