Fast delivery within 72 Hours
B&R 8CVI155S1HCS0.01-1
ACOPOSremote ACOPOSmulti65 inverter module, 15.5 A, AS, IP65, integrated cold plate, 1x SinCos encoder interface, cold plate mounting
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
ACOPOSremote ACOPOSmulti65 inverter module, 15.5 A, AS, IP65, integrated cold plate, 1x SinCos encoder interface, cold plate mounting
Specification
| Module type |
ACOPOSremote module with integrated cold plate |
|---|---|
| B&R ID code |
0xE9EB |
| Power contacts |
Max. 20 A at 40°C |
| Dynamic node allocation (DNA) |
Yes |
| Cooling and mounting type |
Wall mounting |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| Functional safety |
Yes |
| UL |
cULus E225616 |
| Nominal |
5 to 40°C |
| Continuous power consumption |
In preparation |
| Switching frequency 5 kHz |
10 m |
| Switching frequency 10 kHz |
5 m |
| Switching frequency 20 kHz |
5 m |
| DC bus capacitance |
35 µF |
| Variant |
M8 connector |
| Maximum |
60°C |
| Input voltage |
24 VDC +20% / -25% |
| Input capacitance |
In preparation |
| Max. power consumption |
10 W + P24 V out + PHolding brake + PTrigger |
| Quantity |
1 |
| Output voltage |
5 V ±5% |
| Continuous current |
Max. 8 A (max. 4 A per pin) |
| Fuse protection |
Electronic (per pin) |
| 24 VDC, COM |
M8 connector |
| Continuous power per motor connection |
7.5 kW |
| Continuous current per motor connection |
15.5 Aeff |
| Starting at 500 m above sea level |
1.4 A per 1,000 m |
| Peak current |
40 A |
| Nominal switching frequency |
5 kHz |
| Possible switching frequencies |
5 / 10 / 20 kHz |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 |
Limit value curve A |
| Overload protection |
Yes |
| Short-circuit and ground fault protection |
Yes |
| Max. output frequency |
598 Hz |
| U, V, W, PE |
8-pin speedtec connector, size 1 |
| Shield connection |
Yes (via connector housing) |
| Continuous current per connection |
1.1 A |
| Max. internal resistance |
In preparation |
| Extinction potential |
Approx. 30 V |
| Max. extinction energy per switching operation |
1.5 Ws |
| Max. switching frequency |
0.5 Hz |
| Overload and short-circuit protection |
Yes |
| Open-circuit monitoring |
Yes |
| Undervoltage monitoring |
Yes |
| Response threshold for open-circuit monitoring |
Approx. 0.25 A |
| Response threshold for undervoltage monitoring |
24 VDC +0% / -4% |
| Type |
SinCos |
| Line length |
Max. 100 m between two stations (segment length) |
| Transfer rate |
100 Mbit/s |
| Module-side connection |
15-pin female springtec connector |
| Status indicators |
UP/DN LEDs |
| Encoder - ACOPOSremote |
No |
| Encoder monitoring |
Yes |
| Max. encoder cable length |
10 m |
| Load capacity |
300 mA |
| Sense lines |
2, compensation of max. 2 x 0.7 V |
| Overload-proof |
Yes |
| Short-circuit proof |
Yes |
| Signal transmission |
Differential signal, symmetrical |
| Signal frequency (-3 dB) |
DC up to 300 kHz |
| Signal frequency (-5 dB) |
DC up to 400 kHz |
| Differential voltage |
0.5 to 1.25 Vss |
| Common-mode voltage |
Max. ±7 V |
| Terminating resistor |
120 Ω |
| ADC resolution |
12-bit |
| Differential voltage for low |
≤-0.2 V |
| Differential voltage for high |
≥0.2 V |
| Resolution @ 1 VSS |
Number of encoder lines * 5700 |
| Accuracy |
– |
| Noise |
– |
| Circuit |
Sink |
| Input resistance |
1470 Ω |
| Input - ACOPOSremote |
No |
| Input - Input |
No |
| Minimum |
3 l/min |
| Low |
<5 V |
| High |
>15 V |
| Switching delay |
Max. 100 µs |
| Input - Inverter module |
No |
| Input current at nominal voltage |
In preparation |
| Enable 1 → 0, PWM off |
Max. 20.5 ms |
| Enable 0 → 1, ready for PWM |
Max. 100 µs |
| Modulation compared to ground potential |
In preparation |
| OSSD signal connections |
Permitted |
| Rising edge |
In preparation |
| Falling edge |
In preparation |
| Max. line length |
30 m |
| Voltage |
24 VDC |
| Summation current |
Max. 250 mA |
| Resistance range |
500 Ω to 5 kΩ |
| ACP10 |
V2.35.1 and higher |
| Discharge capacitance |
0.1 µF |
| Power dissipation relative to continuous apparent power |
IE2 (10,25) 1.3% |
| Nominal losses in standby mode |
6.5 W |
| Hanging vertically |
Yes |
| Horizontal, face up |
Yes |
| Standing horizontally |
Yes |
| Pollution degree per EN 61800-5-1 |
2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 |
III |
| 3 l/min |
Typ. 0.3 bar |
| 6 l/min |
Typ. 0.7 bar |
| Max. continuous pressure |
5 bar |
| Max. permissible return temperature |
60°C |
| Degree of protection per EN 60529 |
IP65 |
| Storage |
5 to 95%, non-condensing |
| Transport |
Max. 95% at 40°C |
| Operation |
5 to 85%, non-condensing |
| Width |
137 mm |
| Height |
287.2 mm |
| Depth |
131 mm |
| Weight |
In preparation |

Reviews