Fast delivery within 72 Hours
B&R 8BVP0220HW00.000-1
Wide input voltage rangeCapable of regenerationIntegrated connection for temperature sensors2 slots for ACOPOSmulti plug-in modules
ACOPO…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Wide input voltage rangeCapable of regenerationIntegrated connection for temperature sensors2 slots for ACOPOSmulti plug-in modules
ACOPOSmulti power supply module, 22 A, AS, wall mounting
Specification
| B&R ID code |
0xA7CF |
|---|---|
| Dynamic node allocation (DNA) |
Yes |
| Cooling and mounting type |
Wall mounting |
| Slots for plug-in modules |
2 |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
Evaluation ongoing |
| UL |
cULus E225616 |
| KC |
Yes |
| Network configurations |
TT, TN-S, TN-C-S |
| Mains input voltage |
3x 220 to 3x 480 VAC ±10% |
| Frequency |
50 / 60 Hz ±4% |
| Installed load |
Max. 15.6 kW |
| Inrush current at 400 VAC |
Max. 67 A |
| Switch-on interval |
>300 s |
| 230 VAC |
17.4 mF |
| 400 VAC |
5.8 mF |
| 480 VAC |
4 mF |
| Nominal switching frequency |
5 kHz |
| Possible switching frequencies |
5 / 10 kHz |
| Integrated line filter per EN 61800-3, category C3 |
No |
| Integrated regeneration choke |
No |
| Regenerative |
Yes |
| Power factor correction (PFC) |
Yes |
| Line fuse |
Max. 66 A (gG fuses per IEC 60269-1 or Class CC, J, T) |
| L1, L2, L3, PE |
Connector |
| PE |
M5 threaded bolt |
| Shield connection |
Yes |
| With wire end sleeve |
0.5 to 16 mm² |
| UL/C-UL-US |
20 to 6 AWG |
| CSA |
20 to 6 AWG |
| Terminal cable cross section dimension of shield connection |
23 to 35 mm |
| Nominal |
5 to 40°C |
| Continuous power (supply and regeneration) |
15 kW |
| Mains input voltage <3x 400 VAC |
94 W/V * (400 V – Mains input voltage) |
| UDC <750 VDC |
P * (1 – UDC/750) |
| Switching frequency 5 kHz |
[0.28*P²+7.9*P+40] W |
| Switching frequency 10 kHz |
[0.9*P²+5.3*P+110] W |
| Starting at 500 m above sea level |
1.5 kW per 1000 m |
| Peak power (supply and regeneration) |
37.5 kW |
| DC bus capacitance |
495 µF |
| Overload protection |
No |
| Short-circuit and ground fault protection |
No |
| Variant |
ACOPOSmulti backplane |
| Input voltage |
25 VDC ±1.6% |
| Input capacitance |
4.7 µF |
| Max. power consumption |
27 W + PSLOT1 + PSLOT2 + P24 V Out + PFan8BVF… |
| Quantity |
2 |
| DC bus voltage (UDC): 260 to 315 VDC |
25 VDC * (UDC / 315) |
| DC bus voltage (UDC): 315 to 800 VDC |
24 VDC ±6% |
| Fuse protection |
250 mA (slow-blow) electronic, automatic reset |
| Output voltage |
24 V +5.8% / -0.1% |
| Continuous current |
4.2 A |
| Max. overcurrent limiting |
10 A |
| Short-circuit proof |
Yes |
| Open-circuit monitoring |
No |
| Undervoltage monitoring |
No |
| Circuit |
Sink |
| Input - Power supply module |
Yes |
| Input - Input |
Yes |
| Maximum |
55°C |
| Low |
<5 V |
| High |
>15 V |
| Input current at nominal voltage |
Approx. 10 mA |
| Rising edge |
52 μs ±0.5 μs (digitally filtered) |
| Falling edge |
53 μs ±0.5 μs (digitally filtered) |
| Modulation compared to ground potential |
Max. ±38 V |
| Discharge capacitance |
0.9 µF |
| Power dissipation relative to continuous apparent power |
IE2 (10,25) 0.7% |
| Nominal losses in standby mode |
10.8 W |
| Hanging vertically |
Yes |
| Horizontal, face up |
Yes |
| Standing horizontally |
No |
| Pollution degree per EN 61800-5-1 |
2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 |
III |
| Degree of protection per EN 60529 |
IP20 |
| Storage |
5 to 95% |
| Transport |
Max. 95% at 40°C |
| Operation |
5 to 85% |
| Width |
106.5 mm |
| Height |
317 mm |
| Wall mounting |
263 mm |
| Weight |
Approx. 5.2 kg |
| Module width |
2 |

Reviews
Clear filtersThere are no reviews yet.