Fast delivery within 72 Hours
B&R 8BVI1650HCSS.004-4
ACOPOSmulti3 SafeMOTION EnDat 2.2 Gen2 inverter module, 165 A, AS, cold plate or pass-through mounting, optimized for applications with decentralized, computationally intensive open-loop and closed-lo…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
ACOPOSmulti3 SafeMOTION EnDat 2.2 Gen2 inverter module, 165 A, AS, cold plate or pass-through mounting, optimized for applications with decentralized, computationally intensive open-loop and closed-loop control requirements
Specification
| B&R ID code |
0x2EEB |
|---|---|
| Automation Studio |
4.6.1.x or later |
| Mapp Technology Package |
mapp Safety 5.24.0 or later |
| Dynamic node allocation (DNA) |
Yes |
| Cooling and mounting type |
Cold plate or pass-through mounting |
| Slots for plug-in modules |
2 |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| Functional safety |
Yes (openSAFETY) |
| UL |
cULus E225616Power conversion equipment |
| KC |
Yes |
| Nominal |
5 to 40°C |
| Continuous power consumption |
121.8 kW |
| Switching frequency 5 kHz |
25 m |
| Switching frequency 10 kHz |
25 m |
| Switching frequency 20 kHz |
25 m |
| DC bus capacitance |
3630 µF |
| Variant |
ACOPOSmulti backplane |
| Input voltage |
25 VDC ±1.6% |
| Input capacitance |
32.9 µF |
| Max. power consumption |
43 W + PSMC1 + PSLOT2 + P24 V Out + PHoldingBrake |
| Quantity |
1 |
| DC bus voltage (UDC): 260 to 315 VDC |
25 VDC * (UDC/315) |
| DC bus voltage (UDC): 315 to 800 VDC |
24 VDC ±6% |
| Fuse protection |
250 mA (slow-blow) electronic, automatic reset |
| Continuous power per motor connection |
120 kW |
| Continuous current per motor connection |
165 Aeff |
| Cold plate mounting |
0.93 A/K (starting at -96°C) |
| Pass-through mounting |
209 mm |
| Starting at 500 m above sea level |
16.5 Aeff per 1000 m |
| Peak current |
330 Aeff |
| Nominal switching frequency |
5 kHz |
| Possible switching frequencies |
5 / 10 / 20 kHz |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 |
Limit value curve A |
| Overload protection |
Yes |
| Short-circuit and ground fault protection |
Yes |
| Max. output frequency |
598 Hz |
| U, V, W, PE |
M8 threaded bolts |
| Shield connection |
Yes |
| Flexible and fine-stranded wires |
— |
| Terminal cable cross section dimension of shield connection |
12 to 50 mm |
| Output voltage |
Typ. 12.5 V |
| Continuous current per connection |
4.2 A |
| Max. internal resistance |
0.15 Ω |
| Extinction potential |
Approx. 30 V |
| Max. extinction energy per switching operation |
3 Ws |
| Max. switching frequency |
0.5 Hz |
| Overload and short-circuit protection |
Yes |
| Open-circuit monitoring |
Yes |
| Undervoltage monitoring |
Yes |
| Response threshold for open-circuit monitoring |
Approx. 0.5 A |
| Response threshold for undervoltage monitoring |
24 VDC -2% / -4% |
| Type |
EnDat 2.2 |
| Connections |
9-pin female DSUB connector |
| Status indicators |
UP/DN LEDs |
| Encoder - ACOPOSmulti |
No |
| Encoder monitoring |
Yes |
| Max. encoder cable length |
100 m Depends on the cross section of the power supply wires in the encoder cable |
| Load capacity |
350 mA |
| Short-circuit proof |
Yes |
| Overload-proof |
Yes |
| Signal transmission |
RS485 |
| Data transfer rate |
6.25 Mbit/s |
| Max. power consumption per encoder interface |
PSMC[W] = 19 V * IEncoder[A] |
| Circuit |
Sink |
| Input - Inverter module |
Yes |
| Input - Input |
Yes |
| Maximum |
55°C |
| Low |
<5 V |
| High |
>15 V |
| Input current at nominal voltage |
Approx. 10 mA |
| Rising edge |
52 µs ±0.5 µs (digitally filtered) |
| Falling edge |
53 µs ±0.5 µs (digitally filtered) |
| Modulation compared to ground potential |
Max. ±38 V |
| Resistance range |
500 Ω to 5 kΩ |
| Mapp Motion |
5.24.1 and higher |
| ACP10/ARNC0 |
5.24.1 and higher |
| Discharge capacitance |
0.9 µF |
| Power dissipation relative to continuous apparent power |
IE2 (10,25) 0.6%IE2 (50,25) 0.6%IE2 (10,50) 0.8%IE2 (50,50) 0.8%IE2 (90,50) 0.8%IE2 (10,100) 1.4%IE2 (50,100) 1.4%IE2 (90,100) 1.4% |
| Nominal losses in standby mode |
16 W |
| Hanging vertically |
Yes |
| Horizontal, face up |
Yes |
| Standing horizontally |
No |
| Pollution degree per EN 61800-5-1 |
2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 |
III |
| Degree of protection per EN 60529 |
IP20 |
| Storage |
5 to 95% |
| Transport |
Max. 95% at 40°C |
| Operation |
5 to 85% |
| Width |
427.5 mm |
| Height |
317 mm |
| Cold plate |
212 mm |
| Weight |
17 kg |
| Module width |
8 |

Reviews
Clear filtersThere are no reviews yet.