Fast delivery within 72 Hours
B&R 8BVI0880HCS0.000-1
Integrated uncontrolled standstill and safe stopIntegrated connection for motor holding brake and temperature sensor2 slots for ACOPOSmulti plug-in modules…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Integrated uncontrolled standstill and safe stopIntegrated connection for motor holding brake and temperature sensor2 slots for ACOPOSmulti plug-in modules
ACOPOSmulti inverter module, 88 A, AS, cold plate or pass-through mounting
Specification
| B&R ID code |
0x200C |
|---|---|
| Dynamic node allocation (DNA) |
Yes |
| Cooling and mounting type |
Cold plate or pass-through mounting |
| Slots for plug-in modules |
2 |
| CE |
Yes |
| UKCA |
Yes |
| Functional safety |
Yes |
| UL |
cULus E225616 |
| KC |
Yes |
| Nominal |
5 to 40°C |
| Continuous power consumption |
65 kW |
| Switching frequency 5 kHz |
25 m |
| Switching frequency 10 kHz |
25 m |
| Switching frequency 20 kHz |
25 m |
| DC bus capacitance |
1980 µF |
| Variant |
ACOPOSmulti backplane |
| Input voltage |
25 VDC ±1.6% |
| Input capacitance |
32.9 µF |
| Max. power consumption |
27 W + PSLOT1 + PSLOT2 + P24 V Out + PHoldingBrake |
| Quantity |
1 |
| DC bus voltage (UDC): 260 to 315 VDC |
25 VDC * (UDC/315) |
| DC bus voltage (UDC): 315 to 800 VDC |
24 VDC ±6% |
| Fuse protection |
250 mA (slow-blow) electronic, automatic reset |
| Continuous power per motor connection |
64 kW |
| Continuous current per motor connection |
88 Aeff |
| Cold plate mounting |
0.75 A/K (starting at -37°C) |
| Pass-through mounting |
209 mm |
| Starting at 500 m above sea level |
8.8 Aeff per 1000 m |
| Peak current |
176 Aeff |
| Nominal switching frequency |
5 kHz |
| Possible switching frequencies |
5 / 10 / 20 kHz |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 |
Limit value curve A |
| Overload protection |
Yes |
| Short-circuit and ground fault protection |
Yes |
| Max. output frequency |
598 Hz |
| U, V, W, PE |
M8 threaded bolts |
| Shield connection |
Yes |
| Flexible and fine-stranded wires |
6 to 50 mm² |
| UL/C-UL-US |
In preparation |
| CSA |
In preparation |
| Terminal cable cross section dimension of shield connection |
12 to 50 mm |
| Output voltage |
24 VDC +5.8% / -0% |
| Continuous current per connection |
4.2 A |
| Max. internal resistance |
0.15 Ω |
| Extinction potential |
Approx. 30 V |
| Max. extinction energy per switching operation |
3 Ws |
| Max. switching frequency |
0.5 Hz |
| Overload and short-circuit protection |
Yes |
| Open-circuit monitoring |
Yes |
| Undervoltage monitoring |
Yes |
| Response threshold for open-circuit monitoring |
Approx. 0.5 A |
| Response threshold for undervoltage monitoring |
24 VDC +0% / -4% |
| Circuit |
Sink |
| Input - Inverter module |
Yes |
| Input - Input |
Yes |
| Maximum |
55°C |
| Input current at nominal voltage |
Approx. 10 mA |
| Low |
<5 V |
| High |
>15 V |
| Enable 1 → 0, PWM off |
Max. 20.5 ms |
| Enable 0 → 1, ready for PWM |
Max. 100 µs |
| Modulation compared to ground potential |
Max. ±38 V |
| OSSD signal connections |
Permitted |
| Rising edge |
52 µs ±0.5 µs (digitally filtered) |
| Falling edge |
53 µs ±0.5 µs (digitally filtered) |
| Resistance range |
500 Ω to 5 kΩ |
| Discharge capacitance |
0.44 µF |
| Hanging vertically |
Yes |
| Horizontal, face up |
Yes |
| Standing horizontally |
No |
| Pollution degree per EN 61800-5-1 |
2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 |
III |
| Degree of protection per EN 60529 |
IP20 |
| Storage |
5 to 95% |
| Transport |
Max. 95% at 40°C |
| Operation |
5 to 85% |
| Width |
213.5 mm |
| Height |
317 mm |
| Cold plate |
212 mm |
| Weight |
Approx. 7.1 kg |
| Module width |
4 |

Reviews
Clear filtersThere are no reviews yet.