Description
For distributing the DC bus power supply and 24 VDC auxiliary supply to multiple mounting platesFor setting up decentralized units in the ACOPOSmulti drive systemOutput for overload protection
ACOPOSmulti expansion module 40 A, AS, cold plate or pass-through mounting
Specification
| Cooling and mounting type | 
 Cold plate or pass-through mounting  | 
|---|---|
| CE | 
 Yes  | 
| UKCA | 
 Yes  | 
| CRA (Cyber Resilience Act) | 
 Not applicable  | 
| UL | 
 cULus E225616Power conversion equipment  | 
| KC | 
 Yes  | 
| Nominal | 
 5 to 40°C  | 
| 10 A | 
 No (overload indicated via LED, dry alarm contacts present)  | 
| 20 A | 
 No (overload indicated via LED, dry alarm contacts present)  | 
| 50 A | 
 No (overload indicated via LED, dry alarm contacts present)  | 
| Reduction of continuous power at ambient temperatures starting at 40°C | 
 1.25% per °Kelvin  | 
| Starting at 500 m above sea level | 
 10% per 1000 m  | 
| Reduction of continuous power depending on cooling method | 
 No reduction  | 
| Power dissipation with continuous power | 
 200 W  | 
| Variant | 
 ACOPOSmulti backplane  | 
| Input voltage | 
 25 VDC ±1.6%  | 
| 12 A | 
 240 W  | 
| 30 A | 
 600 W  | 
| Max. power consumption | 
 5 W  | 
| Quantity | 
 2  | 
| Type | 
 Melting fuse ø 10 x 38 mm  | 
| Tripping characteristic | 
 Fast-acting  | 
| Rated current | 
 12 / 30 A  | 
| Short-circuit and ground fault protection | 
 Yes  | 
| Max. line length between two expansion modules | 
 5 m  | 
| DC+, DC-, PE | 
 Connector  | 
| Shield connection | 
 No  | 
| With wire end sleeve | 
 0.25 to 6 mm²  | 
| UL/C-UL-US | 
 22 to 10 AWG  | 
| CSA | 
 22 to 10 AWG  | 
| Terminal cable cross section dimension of shield connection | 
 12 to 22 mm  | 
| DC bus voltage (UDC): 260 to 315 VDC | 
 25 VDC * (DC bus voltage / 315)  | 
| DC bus voltage (UDC): 315 to 800 VDC | 
 24 VDC ±6%  | 
| Overload protection | 
 Yes  | 
| Short-circuit proof | 
 No  | 
| 24 VDC, COM | 
 Connector  | 
| Alarm contact 1 | 
 Normally closed contact  | 
| Alarm contact 2 | 
 Normally open contact  | 
| Alarm contact - ACOPOSmulti module | 
 Yes  | 
| Alarm contact - Alarm contact | 
 Yes  | 
| Nominal voltage | 
 30 VDC  | 
| Maximum current | 
 1 A  | 
| Switching delay | 
 3 ms  | 
| Max. number of switching cycles | 
 100,000  | 
| Overload-proof | 
 No  | 
| Hanging vertically | 
 Yes  | 
| Horizontal, face up | 
 Yes  | 
| Standing horizontally | 
 No  | 
| Maximum | 
 55°C  | 
| Pollution degree per EN 61800-5-1 | 
 2 (non-conductive pollution)  | 
| Overvoltage category per EN 61800-5-1 | 
 III  | 
| Degree of protection per EN 60529 | 
 IP20  | 
| Storage | 
 5 to 95%  | 
| Transport | 
 Max. 95% at 40°C  | 
| Operation | 
 5 to 85%  | 
| Width | 
 53 mm  | 
| Height | 
 317 mm  | 
| Cold plate | 
 212 mm  | 
| Pass-through mounting | 
 209 mm  | 
| Weight | 
 Approx. 2.6 kg  | 
| Module width | 
 1  | 
	
	
				
		
		
		
		
		
		
		