Fast delivery within 72 Hours
B&R 8B0P0440HW00.001-1
Wide input voltage rangeIntegrated connection for external braking resistorPassive motor short circuit brake
ACOPOSmulti power supply mod…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Wide input voltage rangeIntegrated connection for external braking resistorPassive motor short circuit brake
ACOPOSmulti power supply module passive, 44 A, AS, wall mounting, passive motor short circuit brake
Specification
| Note |
Integrated passive motor short circuit brake |
|---|---|
| B&R ID code |
0xA989 |
| Dynamic node allocation (DNA) |
Yes |
| Cooling and mounting type |
Wall mounting |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| UL |
cULus E225616Power conversion equipment |
| KC |
Yes |
| Network configurations |
TT, TN-S, TN-C-S |
| Mains input voltage |
3x 380 to 3x 500 VAC ±10% |
| Frequency |
50 / 60 Hz ±4% |
| Installed load |
Max. 30.4 kVA |
| Power dissipation with continuous power |
In preparation |
| Inrush current at 400 VAC |
10 A |
| Switch-on interval |
>120 s |
| 400 VAC |
14.4 mF |
| 480 VAC |
10 mF |
| Integrated line filter per EN 61800-3, category C3 |
No |
| Integrated regeneration choke |
No |
| Regenerative |
No |
| Power factor correction (PFC) |
No |
| Line fuse |
Max. 132 A (gG fuses per IEC 60269-1 or Class CC, J, T) Max. 110 A (circuit breaker per EN 60947-2 or UL 489) |
| L1, L2, L3, PE |
Connector |
| PE |
M5 threaded bolt |
| Shield connection |
Yes |
| With wire end sleeve |
0.5 to 6 mm² |
| UL/C-UL-US |
20 to 6 AWG |
| CSA |
20 to 6 AWG |
| Terminal cable cross section dimension of shield connection |
23 to 35 mm |
| Nominal |
5 to 40°C |
| Continuous power |
3 kW |
| Mains input voltage <3x 400 VAC |
40 W/V * (400 V – Mains input voltage) |
| Starting at 500 m above sea level |
1.6 kW per 1000 m |
| Reduction of continuous power depending on cooling method |
In preparation |
| Peak power output (supply) |
48 kW |
| DC bus capacitance |
1320 µF |
| Overload protection |
Yes |
| Short-circuit and ground fault protection |
Yes (with RB+ by externally replaceable melting fuse) |
| Variant |
ACOPOSmulti backplane |
| Input voltage |
25 VDC ±1.6% |
| Input capacitance |
23.5 µF |
| Max. power consumption |
12 W |
| Peak power output |
65 kW (max. 1 s) |
| Min. braking resistance |
7.5 Ω |
| Rated current of built-in fuse |
30 A (fast-acting) |
| RB+, RB-, PE |
Connector |
| Discharge capacitance |
0.9 µF |
| Power dissipation relative to continuous apparent power |
IE2 (10;25) 0.2%IE2 (50;25) 0.3%IE2 (10;50) 0.2%IE2 (50;50) 0.3%IE2 (90;50) 0.6%IE2 (10;100) 0.3%IE2 (50;100) 0.6%IE2 (90;100) 1.3% |
| Nominal losses in standby mode |
6 W |
| Hanging vertically |
Yes |
| Horizontal, face up |
Yes |
| Standing horizontally |
No |
| Maximum |
55°C |
| Pollution degree per EN 61800-5-1 |
2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 |
III |
| Degree of protection per EN 60529 |
IP20 |
| Storage |
5 to 95% |
| Transport |
Max. 95% at 40°C |
| Operation |
5 to 85% |
| Width |
106.5 mm |
| Height |
317 mm |
| Wall mounting |
263 mm |
| Weight |
Approx. 6.1 kg |
| Module width |
2 |

Reviews
Clear filtersThere are no reviews yet.