Fast delivery within 72 Hours
B&R 8B0P0440HC00.000-1
Wide input voltage rangeIntegrated connection for external braking resistor
ACOPOSmulti power supply module passive, 44 A, AS, cold plate…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Wide input voltage rangeIntegrated connection for external braking resistor
ACOPOSmulti power supply module passive, 44 A, AS, cold plate or pass-through mounting
Specification
| B&R ID code | 0xA8E8 |
|---|---|
| Dynamic node allocation (DNA) | Yes |
| Cooling and mounting type | Cold plate or pass-through mounting |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| UL | cULus E225616Power conversion equipment |
| KC | Yes |
| Network configurations | TT, TN-S, TN-C-S |
| Mains input voltage | 3x 380 to 3x 500 VAC ±10% |
| Frequency | 50 / 60 Hz ±4% |
| Installed load | Max. 30.4 kVA |
| Power dissipation with continuous power | In preparation |
| Inrush current at 400 VAC | 10 A |
| Switch-on interval | >120 s |
| 400 VAC | 14.4 mF |
| 480 VAC | 10 mF |
| Integrated line filter per EN 61800-3, category C3 | No |
| Integrated regeneration choke | No |
| Regenerative | No |
| Power factor correction (PFC) | No |
| Line fuse | Max. 132 A (gG fuses per IEC 60269-1 or Class CC, J, T)Max. 110 A (circuit breaker per EN 60947-2 or UL 489) |
| L1, L2, L3, PE | Connector |
| PE | M5 threaded bolt |
| Shield connection | Yes |
| With wire end sleeve | 0.5 to 6 mm² |
| UL/C-UL-US | 20 to 8 AWG |
| CSA | 20 to 8 AWG |
| Terminal cable cross section dimension of shield connection | 23 to 35 mm |
| Nominal | 5 to 40°C |
| Continuous power | 3 kW |
| Mains input voltage <3x 400 VAC | 40 W/V * (400 V – Mains input voltage) |
| Starting at 500 m above sea level | 1.6 kW per 1000 m |
| Reduction of continuous power depending on cooling method | In preparation |
| Peak power output (supply) | 48 kW |
| DC bus capacitance | 1320 µF |
| Overload protection | Yes |
| Short-circuit and ground fault protection | Yes (with RB+ by externally replaceable melting fuse) |
| Variant | ACOPOSmulti backplane |
| Input voltage | 25 VDC ±1.6% |
| Input capacitance | 23.5 µF |
| Max. power consumption | 12 W |
| Peak power output | 65 kW (max. 1 s) |
| Min. braking resistance | 7.5 Ω |
| Rated current of built-in fuse | 30 A (fast-acting) |
| RB+, RB-, PE | Connector |
| Discharge capacitance | 0.9 µF |
| Power dissipation relative to continuous apparent power | IE2 (10;25) 0.1% IE2 (50;25) 0.1% IE2 (10;50) 0.1% IE2 (50;50) 0.2% IE2 (90;50) 0.5% IE2 (10;100) 0.1% IE2 (50;100) 0.5% IE2 (90;100) 1.2% |
| Nominal losses in standby mode | 6 W |
| Hanging vertically | Yes |
| Horizontal, face up | Yes |
| Standing horizontally | No |
| Maximum | 55°C |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Degree of protection per EN 60529 | IP20 |
| Storage | 5 to 95% |
| Transport | Max. 95% at 40°C |
| Operation | 5 to 85% |
| Width | 106.5 mm |
| Height | 317 mm |
| Cold plate | 212 mm |
| Pass-through mounting | 209 mm |
| Weight | Approx. 4.9 kg |
| Module width | 2 |
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “B&R 8B0P0440HC00.000-1” Cancel reply

Reviews
Clear filtersThere are no reviews yet.