Fast delivery within 72 Hours

B&R 8B0P0220HW00.000-1

Wide input voltage rangeIntegrated connection for external braking resistor

ACOPOSmulti power supply module passive, 22 A, AS, wall mount…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

Wide input voltage rangeIntegrated connection for external braking resistor

ACOPOSmulti power supply module passive, 22 A, AS, wall mounting

Specification

B&R ID code

0xA8E9

Dynamic node allocation (DNA)

Yes

Cooling and mounting type

Wall mounting

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

UL

cULus E225616
Power conversion equipment

KC

Yes

Network configurations

TT, TN-S, TN-C-S

Mains input voltage

3x 380 to 3x 500 VAC ±10%

Frequency

50 / 60 Hz ±4%

Installed load

Max. 15.6 kVA

Power dissipation with continuous power

In preparation

Inrush current at 400 VAC

10 A

Switch-on interval

>120 s

400 VAC

14.4 mF

480 VAC

10 mF

Integrated line filter per EN 61800-3, category C3

No

Integrated regeneration choke

No

Regenerative

No

Power factor correction (PFC)

No

Line fuse

Max. 66 A (gG fuses per IEC 60269-1 or Class CC, J, T)
Max. 55 A (circuit breaker per EN 60947-2 or UL 489)

L1, L2, L3, PE

Connector

PE

M5 threaded bolt

Shield connection

Yes

With wire end sleeve

0.5 to 6 mm²

UL/C-UL-US

20 to 8 AWG

CSA

20 to 8 AWG

Terminal cable cross section dimension of shield connection

23 to 35 mm

Nominal

5 to 40°C

Continuous power

3 kW

Mains input voltage <3x 400 VAC

20 W/V * (400 V – Mains input voltage)

Starting at 500 m above sea level

0.8 kW per 1000 m

Reduction of continuous power depending on cooling method

In preparation

Peak power output (supply)

24 kW

DC bus capacitance

660 µF

Overload protection

Yes

Short-circuit and ground fault protection

Yes (with RB+ by externally replaceable melting fuse)

Variant

ACOPOSmulti backplane

Input voltage

25 VDC ±1.6%

Input capacitance

23.5 µF

Max. power consumption

12 W

Peak power output

40 kW (max. 0.2 s)

Min. braking resistance

12 Ω

Rated current of built-in fuse

30 A (fast-acting)

RB+, RB-, PE

Connector

Discharge capacitance

0.9 µF

Power dissipation relative to continuous apparent power

IE2 (10;25) 0.4%
IE2 (50;25) 0.5%
IE2 (10;50) 0.4%
IE2 (50;50) 0.6%
IE2 (90;50) 0.8%
IE2 (10;100) 0.5%
IE2 (50;100) 0.8%
IE2 (90;100) 1.5%

Nominal losses in standby mode

6 W

Hanging vertically

Yes

Horizontal, face up

Yes

Standing horizontally

No

Maximum

55°C

Pollution degree per EN 61800-5-1

2 (non-conductive pollution)

Overvoltage category per EN 61800-5-1

III

Degree of protection per EN 60529

IP20

Storage

5 to 95%

Transport

Max. 95% at 40°C

Operation

5 to 85%

Width

106.5 mm

Height

317 mm

Wall mounting

263 mm

Weight

Approx. 5.9 kg

Module width

2

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R 8B0P0220HW00.000-1”

Your email address will not be published. Required fields are marked *