Fast delivery within 72 Hours

B&R 8B0P0110HC00.000-1

Passive power supply modules act as the central power supply for ACOPOSmulti drives and feed the DC bus. They are not subjected to a control loop and therefore cannot provide regeneration.The 8B0P0110…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

Passive power supply modules act as the central power supply for ACOPOSmulti drives and feed the DC bus. They are not subjected to a control loop and therefore cannot provide regeneration.The 8B0P0110HC00.000-1 passive power supply module has an integrated line filter and internal braking resistor. It is also possible to connect an optional external braking resistor. In addition, an interface for connecting 24 VDC is also available. This allows the internal 24 VDC supply to provide an ACOPOSmulti drive system with up to 90 watts of nominal power. This eliminates the need for an 8B0C auxiliary supply module in many applications. The system can start either from external 24 VDC or mains power.

ACOPOSmulti power supply module, passive, 11 A, AS, cold plate or pass-through mounting, 24 V In 1x, integrated line filter

Specification

B&R ID code

0xDD94

Dynamic node allocation (DNA)

Yes

Cooling and mounting type

Cold plate or pass-through mounting

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

UL

cULus E225616Power conversion equipment

Network configurations

TT, TN-S, TN-C-S

Mains input voltage

3x 208 to 3x 480 VAC ±10%

Frequency

50 / 60 Hz ±4%

Installed load

Max. 6.7 kVA

Power dissipation with continuous power

[2.8 * P² + 0.5 * P + 10] W

Inrush current at 400 VAC

2 A

Switch-on interval

>120 s

230 VAC

9 mF

400 VAC

3 mF

480 VAC

2 mF

Integrated line filter per EN 61800-3, category C3

Yes

Integrated regeneration choke

No

Regenerative

No

Power factor correction (PFC)

No

Line fuse

Max. 33 A (gG fuses per IEC 60269-1 or Class CC, J, T) Max. 27.5 A (circuit breaker per EN 60947-2 or UL 489)

L1, L2, L3, PE

Connector

PE

M5 threaded bolt

Shield connection

Yes

With wire end sleeve

0.5 to 6 mm²

UL/C-UL-US

20 to 6 AWG

CSA

20 to 6 AWG

Terminal cable cross section dimension of shield connection

23 to 35 mm

Nominal

5 to 40°C

Continuous power

4 kW

Mains input voltage <3x 400 VAC

10 W/V * (400 V – Mains input voltage)

Starting at 500 m above sea level

0.4 kW per 1000 m

Reduction of continuous power depending on cooling method

No reduction

Peak power output (supply)

12 kW

DC bus capacitance

330 µF

Overload protection

Yes

Short-circuit and ground fault protection

Yes (with RB+ by externally replaceable melting fuse)

Variant

ACOPOSmulti backplane

Input voltage

25 VDC ±1.6%

Input capacitance

23.5 µF

Max. power consumption

12 W

Minimum

18 VDC

Maximum

55°C

24 VDC internal system power supply

25 VDC ±1.6% (regulated)

Switch-on threshold

16 V

Max. continuous current

4.0 A

Status indicators

24 V LED

Undervoltage detection

Yes

Overvoltage detection

Yes

No-load proof

Yes

Overload-proof

Yes

Short-circuit proof

Yes

Overtemperature protection

Yes

24 VDC In, COM

Connector

With wire end sleeves

0.2 to 2.5 mm²

Peak power int./ext.

2 kW / 24 kW (max. 1 s)

Continuous power int./ext.

150 W / 8 kW

Min. braking resistance

25 Ω

Rated current of built-in fuse

15 A (fast-acting)

RB+, RB-, PE

Connector

Discharge capacitance

0.4 µF

Power dissipation relative to continuous apparent power

IE2 (10;25) 0.4% IE2 (50;25) 0.5% IE2 (10;50) 0.4% IE2 (50;50) 0.5% IE2 (90;50) 0.7% IE2 (10;100) 0.5% IE2 (50;100) 0.7% IE2 (90;100) 1.3%

Nominal losses in standby mode

6 W

Hanging vertically

Yes

Horizontal, face up

Yes

Standing horizontally

No

Pollution degree per EN 61800-5-1

2 (non-conductive pollution)

Overvoltage category per EN 61800-5-1

III

Degree of protection per EN 60529

IP20

Storage

5 to 95%

Transport

Max. 95% at 40°C

Operation

5 to 85%

Width

53.5 mm

Height

317 mm

Cold plate

212 mm

Pass-through mounting

209 mm

Weight

3.5 kg

Module width

1

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.