Fast delivery within 72 Hours
B&R 8B0C0320HW00.00A-1
Input for connecting an external 24 VDC source (e.g. UPS)Connections for supplying external 24 V devicesExtensive protective measures
ACO…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Input for connecting an external 24 VDC source (e.g. UPS)Connections for supplying external 24 V devicesExtensive protective measures
ACOPOSmulti auxiliary supply module, 32 A, AS, wall mounting, 24 VIn 1x 30 A, 24 VOut 1x 30 A, 1x 5 A
Specification
| Cooling and mounting type |
Wall mounting |
|---|---|
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| UL |
cULus E225616 |
| KC |
Yes |
| Nominal |
5 to 40°C |
| Operating range in continuous operation |
260 to 800 VDC |
| Full continuous power |
315 to 800 VDC |
| Continuous power consumption |
Max. 880 W |
| Power dissipation with continuous power |
22 W (0% continuous power) |
| DC bus capacitance |
220 nF |
| Variant |
Connector |
| Continuous power |
800 W |
| DC bus voltage (UDC): 260 to 315 VDC |
25 VDC * (UDC / 315) |
| DC bus voltage (UDC): 315 to 800 VDC |
24 VDC ±6% |
| Normal mode (via DC bus) |
32 ADC |
| Supply mode (via +24 Vin) |
30 ADC |
| Reduction of continuous power at ambient temperatures starting at 40°C |
No reduction |
| Starting at 500 m above sea level |
80 W per 1000 m |
| Reduction of continuous power depending on cooling method |
No reduction |
| Startup delay |
Max. 1 s |
| Startup time |
Approx. 5 to 20 ms |
| Residual ripple |
Typ. 50 mVSS |
| Output voltage |
25 VDC ±1.6% |
| DC bus voltage (UDC): 350 to 800 VDC |
42 ADC |
| No-load proof |
Yes |
| Overload-proof |
Yes, ticker operation on overload (TON = 1 s,TOFF = 2.4 s) |
| Short-circuit proof |
Yes |
| Feedback protection |
Max. 35 VDC (also when the power is switched off) |
| Overtemperature protection |
Yes |
| Dielectric strength to ground |
±50 VDC |
| Output/Input isolation |
SELV / PELV requirements |
| Protection of 24 VDC Out 1 output |
30 A (slow-blow) electronic, automatic reset |
| Protection of 24 VDC Out 2 output |
5 A (slow-blow) electronic, automatic reset |
| 24 VDC, COM |
Connector |
| With wire end sleeve |
0.25 to 2.5 mm² |
| UL/C-UL-US |
22 to 10 AWG |
| CSA |
22 to 10 AWG |
| Circuit |
Sink |
| Input - 24 VDC |
Yes |
| Modulation compared to ground potential |
Max. ±50 V |
| Maximum |
55°C |
| Low (24 VDC Out 1 is switched on) |
<5 V |
| High (24 VDC Out 1 is switched off) |
>15 V |
| Input current at nominal voltage |
Approx. 10 mA |
| ON (24 VDC Out 1 is switched on) |
Max. 25 ms |
| OFF (24 VDC Out 1 is switched off) |
Max. 0.25 ms |
| Minimum |
23 VDC |
| Voltage drop between input and internal 24 VDC system power supply |
<0.5 V |
| Switch-on threshold |
+24 VDC internal system power supply <21.5 VDC |
| Max. continuous current |
30 A |
| When switching to supply mode |
Typ. 5 ms |
| When starting up via 24 Vin |
Typ. 2 s |
| Status indicators |
24Vi LED |
| Undervoltage detection |
Yes (<20 VDC) |
| Overvoltage detection |
Yes (>26 VDC) |
| 24 VDC In, COM |
Connector |
| With wire end sleeves |
0.5 to 6 mm² |
| Hanging vertically |
Yes |
| Horizontal, face up |
Yes |
| Standing horizontally |
No |
| Pollution degree per EN 61800-5-1 |
2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 |
III |
| Degree of protection per EN 60529 |
IP20 |
| Storage |
5 to 95% |
| Transport |
Max. 95% at 40°C |
| Operation |
5 to 85% |
| Width |
53 mm |
| Height |
317 mm |
| Wall mounting |
263 mm |
| Weight |
Approx. 3.3 kg |
| Module width |
1 |

Reviews