Fast delivery within 72 Hours

B&R 8B0C0320HC00.B00-1

ACOPOSmulti auxiliary supply module, 35 A, AS, cold plate or pass-through mounting, 42…58 VOut

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

ACOPOSmulti auxiliary supply module, 35 A, AS, cold plate or pass-through mounting, 42…58 VOut

Specification

Cooling and mounting type

Cold plate

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

UL

cULus E225616
Power conversion equipment

Nominal

5 to 40°C

Operating range in continuous operation

260 to 800 VDC

Full continuous power

550 to 800 VDC

Continuous power consumption

Max. 2120 W

Power dissipation with continuous power

15 W (0% continuous power)
30 W (50% continuous power)
90 W (100% continuous power)

DC bus capacitance

1.2 µF

Variant

Connector

Quantity

1

DC bus voltage (UDC): 260 to 315 VDC

25 VDC * (UDC/315)

DC bus voltage (UDC): 315 to 800 VDC

24 VDC ±6%

Fuse protection

250 mA (slow-blow) electronic, automatic reset

24 VDC, COM

Connector

Input voltage

25 VDC ±1.6%

Input capacitance

47 µF

Max. power consumption

7 W + P 24 VDC Out

Workspace

42 to 58 VDC

Residual ripple

Typ. 200 mVSS

Input stability

Typ. <50 mV (dynamic)

Load stability

250 mVSS (dynamic)

Continuous power

(Output voltage / 58 VDC) * 2030 W

Continuous current

±35 A

Peak current

±60 A (max. 2 s)

Depending on ambient temperature

0.2 A/K (starting at 40°C)

Depending on installation elevation

3.5 A per 1000 m (starting at 500 m above sea level)

Depending on the input voltage

0,136 A/V * (600 V – Input voltage)

Depending on cooling type

No reduction

Startup delay

Max. 8 s

Startup time

Typ. 300 ms

No-load proof

Yes

Overload-proof

Yes

Short-circuit proof

Yes

Feedback protection

Yes <63 V

Overtemperature protection

Yes

Output/Input isolation

PELV

Shield connection

Yes

Connection

Parallel connection on output: Not permitted
Serial connection on output: Not permitted

Max. cable length

30 m

Type

POWERLINK V2 controlled node (CN)

Line length

Max. 100 m between 2 stations (segment length)

Transfer rate

100 Mbit/s

Modulation compared to ground potential

±38 VDC

Circuit

Sink

Input current at nominal voltage

Typ. 10 mA

Switching threshold

LOW: <5 VDC
HIGH: >15 VDC

Maximum

55°C

Electrical isolation

Yes

Rising edge

52 ±0.5 µs (digitally filtered)

Falling edge

53 ±0.5 µs (digitally filtered)

Shielding

No

Voltage

Max. 30 VDC

Current

Max. 100 mA

Loop through for STO

Yes

Load pulse

3 mA

Pulse duration

Max. 500 ms

Threshold value for undervoltage warning

5.2 V

Idle current

Max. 10 µA

Mapp Motion

5.13.1 and higher

ACP10/ARNC0

All versions

Hanging vertically

Yes

Horizontal, face up

Yes

Standing horizontally

No

Pollution degree per EN 61800-5-1

2 (non-conductive pollution)

Overvoltage category per EN 61800-5-1

III

Degree of protection per EN 60529

IP20

Storage

5 to 95%

Transport

Max. 95% at 40°C

Operation

5 to 85%

Width

53.5 mm

Height

317 mm

Cold plate

212 mm

Weight

2.6 kg

Module width

1

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R 8B0C0320HC00.B00-1”