Fast delivery within 72 Hours
B&R 8B0C0320HC00.B00-1
ACOPOSmulti auxiliary supply module, 35 A, AS, cold plate or pass-through mounting, 42…58 VOut
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
ACOPOSmulti auxiliary supply module, 35 A, AS, cold plate or pass-through mounting, 42…58 VOut
Specification
| Cooling and mounting type |
Cold plate |
|---|---|
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| UL |
cULus E225616 |
| Nominal |
5 to 40°C |
| Operating range in continuous operation |
260 to 800 VDC |
| Full continuous power |
550 to 800 VDC |
| Continuous power consumption |
Max. 2120 W |
| Power dissipation with continuous power |
15 W (0% continuous power) |
| DC bus capacitance |
1.2 µF |
| Variant |
Connector |
| Quantity |
1 |
| DC bus voltage (UDC): 260 to 315 VDC |
25 VDC * (UDC/315) |
| DC bus voltage (UDC): 315 to 800 VDC |
24 VDC ±6% |
| Fuse protection |
250 mA (slow-blow) electronic, automatic reset |
| 24 VDC, COM |
Connector |
| Input voltage |
25 VDC ±1.6% |
| Input capacitance |
47 µF |
| Max. power consumption |
7 W + P 24 VDC Out |
| Workspace |
42 to 58 VDC |
| Residual ripple |
Typ. 200 mVSS |
| Input stability |
Typ. <50 mV (dynamic) |
| Load stability |
250 mVSS (dynamic) |
| Continuous power |
(Output voltage / 58 VDC) * 2030 W |
| Continuous current |
±35 A |
| Peak current |
±60 A (max. 2 s) |
| Depending on ambient temperature |
0.2 A/K (starting at 40°C) |
| Depending on installation elevation |
3.5 A per 1000 m (starting at 500 m above sea level) |
| Depending on the input voltage |
0,136 A/V * (600 V – Input voltage) |
| Depending on cooling type |
No reduction |
| Startup delay |
Max. 8 s |
| Startup time |
Typ. 300 ms |
| No-load proof |
Yes |
| Overload-proof |
Yes |
| Short-circuit proof |
Yes |
| Feedback protection |
Yes <63 V |
| Overtemperature protection |
Yes |
| Output/Input isolation |
PELV |
| Shield connection |
Yes |
| Connection |
Parallel connection on output: Not permitted |
| Max. cable length |
30 m |
| Type |
POWERLINK V2 controlled node (CN) |
| Line length |
Max. 100 m between 2 stations (segment length) |
| Transfer rate |
100 Mbit/s |
| Modulation compared to ground potential |
±38 VDC |
| Circuit |
Sink |
| Input current at nominal voltage |
Typ. 10 mA |
| Switching threshold |
LOW: <5 VDC |
| Maximum |
55°C |
| Electrical isolation |
Yes |
| Rising edge |
52 ±0.5 µs (digitally filtered) |
| Falling edge |
53 ±0.5 µs (digitally filtered) |
| Shielding |
No |
| Voltage |
Max. 30 VDC |
| Current |
Max. 100 mA |
| Loop through for STO |
Yes |
| Load pulse |
3 mA |
| Pulse duration |
Max. 500 ms |
| Threshold value for undervoltage warning |
5.2 V |
| Idle current |
Max. 10 µA |
| Mapp Motion |
5.13.1 and higher |
| ACP10/ARNC0 |
All versions |
| Hanging vertically |
Yes |
| Horizontal, face up |
Yes |
| Standing horizontally |
No |
| Pollution degree per EN 61800-5-1 |
2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 |
III |
| Degree of protection per EN 60529 |
IP20 |
| Storage |
5 to 95% |
| Transport |
Max. 95% at 40°C |
| Operation |
5 to 85% |
| Width |
53.5 mm |
| Height |
317 mm |
| Cold plate |
212 mm |
| Weight |
2.6 kg |
| Module width |
1 |

Reviews
Clear filtersThere are no reviews yet.