Fast delivery within 72 Hours

B&R 8B0C0320HC00.00A-1

Input for connecting an external 24 VDC source (e.g. UPS)Connections for supplying external 24 V devicesExtensive protective measures

ACO…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

Input for connecting an external 24 VDC source (e.g. UPS)Connections for supplying external 24 V devicesExtensive protective measures

ACOPOSmulti auxiliary supply module, 32 A, AS, cold plate or pass-through mounting, 24 VIn 1x 30 A, 24 VOut 1x 30 A, 1x 5 A

Specification

Cooling and mounting type

Cold plate or pass-through mounting

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

UL

cULus E225616
Power conversion equipment

KC

Yes

Nominal

5 to 40°C

Operating range in continuous operation

260 to 800 VDC

Full continuous power

315 to 800 VDC

Continuous power consumption

Max. 880 W

Power dissipation with continuous power

22 W (0% continuous power)
35 W (50% continuous power)
80 W (100% continuous power)

DC bus capacitance

220 nF

Variant

Connector

Continuous power

800 W

DC bus voltage (UDC): 260 to 315 VDC

25 VDC * (UDC / 315)

DC bus voltage (UDC): 315 to 800 VDC

24 VDC ±6%

Normal mode (via DC bus)

32 ADC

Supply mode (via +24 Vin)

30 ADC

Reduction of continuous power at ambient temperatures starting at 40°C

No reduction

Starting at 500 m above sea level

80 W per 1000 m

Reduction of continuous power depending on cooling method

No reduction

Startup delay

Max. 1 s

Startup time

Approx. 5 to 20 ms

Residual ripple

Typ. 50 mVSS

Output voltage

25 VDC ±1.6%

DC bus voltage (UDC): 350 to 800 VDC

42 ADC

No-load proof

Yes

Overload-proof

Yes, ticker operation on overload (TON = 1 s,TOFF = 2.4 s)

Short-circuit proof

Yes

Feedback protection

Max. 35 VDC (also when the power is switched off)

Overtemperature protection

Yes

Dielectric strength to ground

±50 VDC

Output/Input isolation

SELV / PELV requirements

Protection of 24 VDC Out 1 output

30 A (slow-blow) electronic, automatic reset

Protection of 24 VDC Out 2 output

5 A (slow-blow) electronic, automatic reset

24 VDC, COM

Connector

With wire end sleeve

0.25 to 2.5 mm²

UL/C-UL-US

22 to 10 AWG

CSA

22 to 10 AWG

Circuit

Sink

Input - 24 VDC

Yes

Modulation compared to ground potential

Max. ±50 V

Maximum

55°C

Low (24 VDC Out 1 is switched on)

<5 V

High (24 VDC Out 1 is switched off)

>15 V

Input current at nominal voltage

Approx. 10 mA

ON (24 VDC Out 1 is switched on)

Max. 25 ms

OFF (24 VDC Out 1 is switched off)

Max. 0.25 ms

Minimum

23 VDC

Voltage drop between input and internal 24 VDC system power supply

<0.5 V

Switch-on threshold

+24 VDC internal system power supply <21.5 VDC

Max. continuous current

30 A

When switching to supply mode

Typ. 5 ms

When starting up via 24 Vin

Typ. 2 s

Status indicators

24Vi LED
ERRi LED

Undervoltage detection

Yes (<20 VDC)

Overvoltage detection

Yes (>26 VDC)

24 VDC In, COM

Connector

With wire end sleeves

0.5 to 6 mm²

Hanging vertically

Yes

Horizontal, face up

Yes

Standing horizontally

No

Pollution degree per EN 61800-5-1

2 (non-conductive pollution)

Overvoltage category per EN 61800-5-1

III

Degree of protection per EN 60529

IP20

Storage

5 to 95%

Transport

Max. 95% at 40°C

Operation

5 to 85%

Width

53 mm

Height

317 mm

Cold plate

212 mm

Pass-through mounting

209 mm

Weight

Approx. 2.9 kg

Module width

1

Customer Reviews