B&R 8B0C0160HC00.001-1
Possibilities for supplying external 24V devicesExtensive protective measures
ACOPOSmulti auxiliary supply module, 16 A, AS, cold plate o…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Possibilities for supplying external 24V devicesExtensive protective measures
ACOPOSmulti auxiliary supply module, 16 A, AS, cold plate or pass-through mounting, 24VOut 1x 16 A, 1x 5 A
Specification
| Cooling and mounting type | Cold plate or pass-through mounting |
|---|---|
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| UL | cULus E225616 Power conversion equipment |
| KC | Yes |
| Nominal | 5 to 40°C |
| Operating range in continuous operation | 260 to 800 VDC |
| Full continuous power | 315 to 800 VDC |
| Continuous power consumption | Max. 445 W |
| Power dissipation with continuous power | 22 W (0% continuous power) 27 W (50% continuous power) 45 W (100% continuous power) |
| DC bus capacitance | 220 nF |
| Variant | Connector |
| Continuous power | 400 W |
| DC bus voltage (UDC): 260 to 315 VDC | 25 VDC * (UDC / 315) |
| DC bus voltage (UDC): 315 to 800 VDC | 24 VDC ±6% |
| Continuous current | 16 ADC |
| Reduction of continuous power at ambient temperatures starting at 40°C | No reduction |
| Starting at 500 m above sea level | 40 W per 1000 m |
| Reduction of continuous power depending on cooling method | No reduction |
| Startup delay | Max. 1 s |
| Startup time | Approx. 5 to 20 ms |
| Residual ripple | Typ. 50 mVSS |
| With wire end sleeve | 0.2 to 2.5 mm² |
| UL/C-UL-US | 30 to 12 AWG |
| CSA | 22 to 12 AWG |
| Output voltage | 25 VDC ±1.6% |
| DC bus voltage (UDC): 350 to 800 VDC | 21 ADC |
| No-load proof | Yes |
| Overload-proof | Yes |
| Short-circuit proof | Yes |
| Feedback protection | Max. 35 VDC (also when the power is switched off) |
| Overtemperature protection | Yes |
| Dielectric strength to ground | ±50 VDC |
| Output/Input isolation | SELV / PELV requirements |
| Protection of 24 VDC Out 1 output | 16 A (slow-blow) electronic, automatic reset |
| Protection of 24 VDC Out 2 output | 5 A (slow-blow) electronic, automatic reset |
| 24 VDC, COM | Connector |
| Circuit | Sink |
| Input - 24 VDC | Yes |
| Modulation compared to ground potential | Max. ±50 V |
| Maximum | 55°C |
| Low (24 VDC Out 1 is switched on) | <5 V |
| High (24 VDC Out 1 is switched off) | >15 V |
| Input current at nominal voltage | Approx. 10 mA |
| ON (24 VDC Out 1 is switched on) | Max. 25 ms |
| OFF (24 VDC Out 1 is switched off) | Max. 0.25 ms |
| Hanging vertically | Yes |
| Horizontal, face up | Yes |
| Standing horizontally | No |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Degree of protection per EN 60529 | IP20 |
| Storage | 5 to 95% |
| Transport | Max. 95% at 40°C |
| Operation | 5 to 85% |
| Width | 53 mm |
| Height | 317 mm |
| Cold plate | 212 mm |
| Pass-through mounting | 209 mm |
| Weight | Approx. 2.7 kg |
| Module width | 1 |